LioN-Safety 8/4-F-DI 4-F-DO 2-IOLM M12 – Ethernet/IP / CIP Safety
LioN-Safety 8/4-F-DI 4-F-DO 2-IOLM M12 EtherNet/IP / CIP Safety , M12 L-coded Power Supply, Metal 60mm, IoT Protocols (OPC UA, MQTT, CoAP, REST)
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
0980 SSL 3131-121-007D-202 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Item Description | Order |
|---|---|---|
| 935023001 | 0980 SSL 3131-121-007D-202 | Order online |
Specifications
Information
| Product Family | I/O Systems: Active - Standalone |
|---|---|
| Side 1 Product Sub Family | LioN-Safety |
| Item Description | 0980 SSL 3131-121-007D-202 |
| Device Type | FS I/O Device |
| Protocol Compatibility | CIP Safety |
| I/O Function | 8/4 FS DI, 4 FS DO, 2 IOLM |
| Bus Connection | M12 LAN, 4-poles, D-coded |
| Power Supply Connection | M12 Power, 5-poles, L-coded |
| I/O Connection | M12, 5-poles, A-coded |
| I/O Type | Functional Safety Digital In-/Output |
| Protection Degree / IP Rating Note | *only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
| System Power Supply Connection Note | *do not connect / disconnect under voltage! |
General Data
| Housing Material | Metal, Zinc Die-cast |
|---|---|
| Housing Plating | Nickel, matt |
| Housing Color | Grey Metallic |
| Protection Degree / IP Rating** | IP65, IP67, IP69K |
| Potted | Yes |
| Dimensions (W x H x D) | 60 mm x 31 mm x 200 mm |
| Weight | approx. 500 g |
| Ambient Temperature (Operation)* | 0 °C to +40 °C (HW: 40) / -40 °C to +70 °C (HW: 50) |
| Ambient Temperature (Storage/Transport) | -40 °C to 85 °C |
| Permissible Humidity (Operation) | 5 % ... 98 % (For UL applications max. 80 %) |
| Permissible Humidity (Storage/Transport) | 5 % ... 98 % (For UL applications max. 80 %) |
| Air Pressure (Operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air Pressure (Storage/Transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Flammabilty Class | UL 94 (IEC 61010) |
| Protection Class | III, IEC 61140, EN 61140, VDE 0140-1 |
| Side 1 Pollution Degree | 3 acc. to EN 60664-1, VDE 0110-1 |
| Vibration Resistance | 15 g / 5 -500 Hz |
| Shock Resistance | 50 g / 11ms |
| Mean Time To Failure (MTTF) | 83 years |
| Contact Base Material | M12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated |
| Contact Bearer Material | PA |
| O-Ring Material | FKM |
| Mount Type | 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts. |
| Fastening Torque (Fixing Screw) | M4: 1 Nm |
| Fastening Torque (Ground Connection (FE)) | M4: 1 Nm |
| Fastening Torque (Bus Connection) | M12: 0.5 Nm |
| Fastening Torque (Power Connection) | M12: 0.5 Nm |
| Fastening Torque (I/O Connection) | M12: 0.5 Nm |
| Included in Delivery | Attachable Labels: 15x, Sealing Caps: 5x M12 |
Safety
| SIL/ SIL CL (IEC 62061/ IEC 61508) | up to 3 |
|---|---|
| Performance Level IL (ISO 13849) | up to e |
| Category Cat. (ISO 13849) | up to 4 |
| Probability of failure per hour (PFH) | 1,37 E-9 - DC avg. 99,37% (F-DO + F-DI dual-channel); 5,36 E-9 - DC avg. 98,60% (F-DO + F-DI single-channel) |
| Mission Time | 20 years |
| Safety Reaction Time | 69ms |
| Safety Digital Inputs | 8/4 |
| Safety Digital Outputs | 4 |
EtherNet/IP
| Protocol (EtherNet/IP) | EtherNet/IP |
|---|---|
| Safety Communication | CIP Safety |
| Connection | M12 LAN, 4-poles, D-coded |
| Number of Connections | 2 |
| Specification | CIP V3.2x, EIP Adaption of CIP V1.2x |
| Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
| Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
| Cycle Time / Requested Packet Interval (RPI) | min. 1 ms |
| Addressing | BootP, DHCP, Rotary Address Switches |
| Address Switches Range | 0 to 255 dec |
| Connection Types | Exclusive Owner, Input Only, Listen Only |
| CIP Msg Connection Limit | 6 |
| CIP I/O Connection Limit | 3 |
| Device Level Ring (DLR) | Supported, beacon based |
| Quick Connect (QC) | Supported, ≤ 500 ms |
| Supported Network Protocols (Other) | ACD, ARP, BootP, DHCP, HTTP, IGMP, Ping, TCP/IP |
EtherCAT
| OPC UA | Cyclic data read/write, Diagnosis data, Event data |
|---|---|
| MQTT | Cyclic data read/write, Diagnosis data, Event data |
| REST API | Cyclic data read/write, Diagnosis data, Event data |
| CoAP | Cyclic data read/write, Diagnosis data, Event data |
IO-Links
| Protocol | IO-Link Master |
|---|---|
| Connection | M12 5-poles, A-coded |
| Number of Connections | 2 |
| Specification | v1.1.3 ready, IEC 61131-9 |
| IO-Link Class | Class A |
| Transmission Rate / COM Mode | COM1, COM2, COM3 |
| Cycle Time / Update Rate | 400μs |
| Parameter Storage | supported |
Power Supply
| Connection Module Supply Voltage | M12 Power, 5-poles, L-coded |
|---|---|
| Number of Connections | 2 |
| Current Carrying Capacity of Connector | max. 16 A |
| Module Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
| Module Supply Voltage (Range) | 18 V DC to 30 V DC |
| Current Consumption (typ.) | typ. 180mA (at 24 V DC) |
| Reverse Polarity Protection | Yes |
| Status Indicator (System Supply) | LED green |
| Diagnostic Indicator | LED red |
| Connection Sensor Supply Voltage | M12 Power, 5-poles, L-coded |
| Sensor Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
| Sensor Supply Voltage (Range) | 18 V DC to 30 V DC |
| Status Indicator (Sensor Supply) | LED green |
| Actuator Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
| Actuator Supply Voltage (Range) | 18 V DC to 30 V DC |
| Status Indicator (Actuator Supply) | LED green |
IO-Link Master Channels
| Number of IO-Link Master Channels | max. 2, configurable |
|---|---|
| Connection | M12, 5-poles, A-coded |
| IO-Link Class A Ports | 2x, X7 and X8 |
| IO-Link Specification | V1.1.3 |
| Parameter Storage | Supported |
| Supported COM Modes | 4.8 kBaud (COM 1), 38.4 kBaud (COM 2), 230.4 kBaud (COM 3) |
| Cycle Time / Update Rate | min. 1 ms for all channels at 32 Byte IN / OUT |
| Nominal Voltage | 24 V DC via US (system power supply) |
| Nominal Current C/Q (Pin 4) | 500mA |
| Nominal Current 1L+ (Pin 1) | 4A |
| Perm. Conductor Length to Device | ≤ 20 m |
| Status Indicator (IOL) | LED green per channel |
| Diagnostic Indicator | LED red per port |
Digital Input Channels
| Number of Digital Input Channels | up to 8 |
|---|---|
| Connection | M12, 5-poles, A-coded |
| Number of Ports | 4x, X1 to X4 |
| Channel Type | Type 3 acc. to IEC 61131-2 |
| Input Wiring | 2-, 3-, 4-wire |
| Nominal Voltage | 24 V DC via US (module power supply) |
| Nominal Current | typ. 3 mA |
| Sensor Current Supply | max. 1500 mA per port |
| Sensor Type | P-switching; Type 3 for DI configurations “Without Test Pulse” and Potential-free switches for DI configurations “With Test Pulse” |
| Input Voltage Range "0" signal | -3 V DC ...+5 V DC |
| Input Voltage Range "1" signal | 11 V DC ... 30 V DC |
| Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
| Diagnostic Indicator | LED white or yellow per channel |
Digital Output Channels
| Number of Digital Output Channels | 4 |
|---|---|
| Connection | M12, 5-poles, A-coded |
| Number of Ports | 2x, X5 and X6 |
| Channel Type | p-switching |
| Output Wiring | 2-wire |
| Nominal Voltage | 24 V DC via UL |
| Output Current per Channel | max. 2 A |
| Output Current per Module | max. 8 A |
| Galvanically Isolated | Yes |
| Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
| Overload Behavior | Auto off and on switching / Manual restart |
| Status Indicator (Outputs) | LED white or yellow per channel |
| Diagnostic Idicator | LED red per channel |
Electrical Isolation
| US (System Supply Voltage) / FE | 32V DC (clamp voltage) |
|---|
Analog Output Channels
| US / UL (Actuator Supply Voltage) | 500 V DC |
|---|---|
| UL / FE | 32V DC (clamp voltage) |
| Bus connection / FE | 2000 V DC |
EMC Conformance
| EMC Directive | 2014/30/EU |
|---|---|
| EN 61000-4-2 Electrostatic Discharge (ESD) | Criterion B; 4 kV contact discharge, 8 kV air discharge |
| EN 61000-4-3 Electromagnetic Field | Criterion A; Field intensity: 10 V/m |
| EN 61000-4-4 Fast Transients (Burst) | Criterion A, 1 kV; Criterion B/DS, 2 kV |
| EN 61000-4-5 Surge Voltage | Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m |
| EN 61000-4-6 Conducted immunity | Criterion A; Test voltage 10 V |
| EN 55022 Radio Interference Properties | Class A |
| EN 55032 Radio Interference Properties | Class A |
Safety & Environmental Compliance
| CE | Yes |
|---|---|
| RoHS Compliant | Yes |
| China RoHS-Compliant | Yes |
Approvals
| FS-Certification | TÜV (Rheinland) IEC 61508, ISO 13849 |
|---|---|
| UL | cULus Listed, UL 61010-1 |
| CSA | Yes, via UL |
| ODVA | Yes |
| IO-Link | Yes |
Notes
| Protection Degree / IP Rating Note | *only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
|---|---|
| System Power Supply Connection Note | *do not connect / disconnect under voltage! |