Belden Store
0980 SSL 3130-121-007D-202

Product Number: 0980 SSL 3130-121-007D-202

LioN-Safety 16/8-F-DI M12 – Ethernet/IP / CIP Safety

LioN-Safety 16/8-F-DI M12 EtherNet/IP / CIP Safety , M12 L-coded Power Supply, Metal 60mm, IoT Protocols (OPC UA, MQTT, CoAP, REST)

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

0980 SSL 3130-121-007D-202 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Item DescriptionOrder
9350230050980 SSL 3130-121-007D-202Order online

Specifications

Information

Product FamilyI/O Systems: Active - Standalone
Side 1 Product Sub FamilyLioN-Safety
Item Description0980 SSL 3130-121-007D-202
Device TypeFS I/O Device
Protocol CompatibilityCIP Safety
I/O Function16/8 FS DI
Bus ConnectionM12 LAN, 4-poles, D-coded
Power Supply ConnectionM12 Power, 5-poles, L-coded
I/O ConnectionM12, 5-poles, A-coded
I/O TypeFunctional Safety Digital Input
Protection Degree / IP Rating Note*only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
System Power Supply Connection Note*do not connect / disconnect under voltage!

General Data

Housing MaterialMetal, Zinc Die-cast
Housing PlatingNickel, matt
Housing ColorGrey Metallic
Protection Degree / IP Rating**IP65, IP67, IP69K
PottedYes
Dimensions (W x H x D)60 mm x 31 mm x 200 mm
Weightapprox. 500 g
Ambient Temperature (Operation)*0 °C to +40 °C (HW: 40) / -40 °C to +70 °C (HW: 50)
Ambient Temperature (Storage/Transport)-40 °C to 85 °C
Permissible Humidity (Operation)5 % ... 98 % (For UL applications max. 80 %)
Permissible Humidity (Storage/Transport)5 % ... 98 % (For UL applications max. 80 %)
Air Pressure (Operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air Pressure (Storage/Transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Flammabilty ClassUL 94 (IEC 61010)
Protection ClassIII, IEC 61140, EN 61140, VDE 0140-1
Side 1 Pollution Degree3 acc. to EN 60664-1, VDE 0110-1
Vibration Resistance15 g / 5 -500 Hz
Shock Resistance50 g / 11ms
Mean Time To Failure (MTTF)106 years
Contact Base MaterialM12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated
Contact Bearer MaterialPA
O-Ring MaterialFKM
Mount Type2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts.
Fastening Torque (Fixing Screw)M4: 1 Nm
Fastening Torque (Ground Connection (FE))M4: 1 Nm
Fastening Torque (Bus Connection)M12: 0.5 Nm
Fastening Torque (Power Connection)M12: 0.5 Nm
Fastening Torque (I/O Connection)M12: 0.5 Nm
Included in DeliveryAttachable Labels: 15x, Sealing Caps: 5x M12

Safety

SIL/ SIL CL (IEC 62061/ IEC 61508)up to 3
Performance Level IL (ISO 13849)up to e
Category Cat. (ISO 13849)up to 4
Probability of failure per hour (PFH)1,25 E-9 - DC avg. 99,41% (F-DI dual-channel); 5,25 E-9 - DC avg. 98,55% (F-DI single-channel)
Mission Time20 years
Safety Reaction Time64ms
Safety Digital Inputs16/8

EtherNet/IP

Protocol (EtherNet/IP)EtherNet/IP
Safety CommunicationCIP Safety
ConnectionM12 LAN, 4-poles, D-coded
Number of Connections2
SpecificationCIP V3.2x, EIP Adaption of CIP V1.2x
Transmission RateFast Ethernet (10/100 Mbit/s), Full Duplex
Transmission Method100 BASE-TX, with auto negotiation and auto crossing
Cycle Time / Requested Packet Interval (RPI)min. 1 ms
AddressingBootP, DHCP, Rotary Address Switches
Address Switches Range0 to 255 dec
Connection TypesExclusive Owner, Input Only, Listen Only
CIP Msg Connection Limit6
CIP I/O Connection Limit3
Device Level Ring (DLR)Supported, beacon based
Quick Connect (QC)Supported, ≤ 500 ms
Supported Network Protocols (Other)ACD, ARP, BootP, DHCP, HTTP, IGMP, Ping, TCP/IP

EtherCAT

OPC UACyclic data read/write, Diagnosis data, Event data
MQTTCyclic data read/write, Diagnosis data, Event data
REST APICyclic data read/write, Diagnosis data, Event data
CoAPCyclic data read/write, Diagnosis data, Event data

Power Supply

Connection Module Supply VoltageM12 Power, 5-poles, L-coded
Number of Connections2
Current Carrying Capacity of Connectormax. 16 A
Module Supply Voltage (Nominal)24 V DC (SELV/PELV)
Module Supply Voltage (Range)18 V DC to 30 V DC
Current Consumption (typ.)typ. 180mA (at 24 V DC)
Reverse Polarity ProtectionYes
Status Indicator (System Supply)LED green
Diagnostic IndicatorLED red
Connection Sensor Supply VoltageM12 Power, 5-poles, L-coded
Sensor Supply Voltage (Nominal)24 V DC (SELV/PELV)
Sensor Supply Voltage (Range)18 V DC to 30 V DC
Status Indicator (Sensor Supply)LED green
Actuator Supply Voltage (Nominal)24 V DC (SELV/PELV)
Actuator Supply Voltage (Range)18 V DC to 30 V DC
Status Indicator (Actuator Supply)LED green

Digital Input Channels

Number of Digital Input Channelsup to 16
ConnectionM12, 5-poles, A-coded
Number of Ports8x, X1 to X8
Channel TypeType 3 acc. to IEC 61131-2
Input Wiring2-, 3-, 4-wire
Nominal Voltage24 V DC via US (module power supply)
Nominal Currenttyp. 3 mA
Sensor Current Supplymax. 1500 mA per port
Sensor TypeP-switching; Type 3 for DI configurations “Without Test Pulse” and Potential-free switches for DI configurations “With Test Pulse”
Input Voltage Range "0" signal-3 V DC ...+5 V DC
Input Voltage Range "1" signal11 V DC ... 30 V DC
Protective CircuitElectronicaly: Overload protection, short-circuit protection
Diagnostic IndicatorLED white or yellow per channel

Electrical Isolation

US (System Supply Voltage) / FE32V DC (clamp voltage)

Analog Output Channels

US / UL (Actuator Supply Voltage)500 V DC
UL / FE32V DC (clamp voltage)
Bus connection / FE2000 V DC

EMC Conformance

EMC Directive2014/30/EU
EN 61000-4-2 Electrostatic Discharge (ESD)Criterion B; 4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 Electromagnetic FieldCriterion A; Field intensity: 10 V/m
EN 61000-4-4 Fast Transients (Burst)Criterion A, 1 kV; Criterion DS, 2 kV
EN 61000-4-5 Surge VoltageCriterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m
EN 61000-4-6 Conducted immunityCriterion A; Test voltage 10 V
EN 55022 Radio Interference PropertiesClass A
EN 55032 Radio Interference PropertiesClass A

Safety & Environmental Compliance

CEYes
RoHS CompliantYes
China RoHS-CompliantYes

Approvals

FS-CertificationTÜV (Rheinland) IEC 61508, ISO 13849
ULcULus Listed, UL 61010-1
CSAYes, via UL
ODVAYes
IO-LinkYes

Notes

Protection Degree / IP Rating Note*only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
System Power Supply Connection Note*do not connect / disconnect under voltage!

Resources

Related lion-safety i/o modules