Belden Store
0980 SSL 3031-121-007D-101

Product Number: 0980 SSL 3031-121-007D-101

LioN-Safety 8/4-F-DI 4-F-DO 2-IOLM M12 – PROFINET / PROFIsafe

LioN-Safety 8/4-F-DI 4-F-DO 2-IOLM M12 PROFINET / PROFIsafe , M12 L-coded Power Supply, Metal 60mm, IoT Protocols (OPC UA, MQTT, CoAP, REST)

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

0980 SSL 3031-121-007D-101 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Item DescriptionOrder
9350230020980 SSL 3031-121-007D-101Order online

Specifications

Information

Product FamilyI/O Systems: Active - Standalone
Side 1 Product Sub FamilyLioN-Safety
Item Description0980 SSL 3031-121-007D-101
Device TypeFS I/O Device
Protocol CompatibilityPROFISAFE
I/O Function8/4 FS DI, 4 FS DO, 2 IOLM
Bus ConnectionM12 LAN, 4-poles, D-coded
Power Supply ConnectionM12 Power, 5-poles, L-coded
I/O ConnectionM12, 5-poles, A-coded
I/O TypeFunctional Safety Digital In-/Output
Protection Degree / IP Rating Note*only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
System Power Supply Connection Note*do not connect / disconnect under voltage!

General Data

Housing MaterialMetal, Zinc Die-cast
Housing PlatingNickel, matt
Housing ColorGrey Metallic
Protection Degree / IP Rating**IP65, IP67, IP69K
PottedYes
Dimensions (W x H x D)60 mm x 31 mm x 200 mm
Weightapprox. 500 g
Ambient Temperature (Operation)*0 °C to +40 °C (HW: 03, 30, 40) / -40 °C to +70 °C (HW: 50)
Ambient Temperature (Storage/Transport)-40 °C to 85 °C
Permissible Humidity (Operation)5 % ... 98 % (For UL applications max. 80 %)
Permissible Humidity (Storage/Transport)5 % ... 98 % (For UL applications max. 80 %)
Air Pressure (Operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air Pressure (Storage/Transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Flammabilty ClassUL 94 (IEC 61010)
Protection ClassIII, IEC 61140, EN 61140, VDE 0140-1
Side 1 Pollution Degree3 acc. to EN 60664-1, VDE 0110-1
Vibration Resistance15 g / 5 -500 Hz
Shock Resistance50 g / 11ms
Mean Time To Failure (MTTF)83 years
Contact Base MaterialM12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated
Contact Bearer MaterialPA
O-Ring MaterialFKM
Mount Type2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts.
Fastening Torque (Fixing Screw)M4: 1 Nm
Fastening Torque (Ground Connection (FE))M4: 1 Nm
Fastening Torque (Bus Connection)M12: 0.5 Nm
Fastening Torque (Power Connection)M12: 0.5 Nm
Fastening Torque (I/O Connection)M12: 0.5 Nm
Included in DeliveryAttachable Labels: 15x, Sealing Caps: 5x M12

Safety

SIL/ SIL CL (IEC 62061/ IEC 61508)up to 3
Performance Level IL (ISO 13849)up to e
Category Cat. (ISO 13849)up to 4
Probability of failure per hour (PFH)1,37 E-9 - DC avg. 99,37% (F-DO + F-DI dual-channel); 5,36 E-9 - DC avg. 98,60% (F-DO + F-DI single-channel)
Mission Time20 years
Safety Reaction Time44ms
Safety Digital Inputs8/4
Safety Digital Outputs4

PROFINET

ProtocolPROFINET
Safety CommunicationPROFIsafe (V2.6.1)
ConnectionM12 LAN, 4-poles, D-coded
Number of Connections2
SpecificationV2.44
Conformance ClassC (CC-C)
Performance ClassRT (switch supports IRT)
Netload ClassIII
Transmission RateFast Ethernet (10/100 Mbit/s), Full Duplex
Transmission Method100 BASE-TX, with auto negotiation and auto crossing
Cycle Time / Update Ratemin. 1 ms
AddressingDCP
Media Redundancy Protocol (MRP)Supported, MRP client
Shared DeviceSupported
Shared Inputnot supported
Topology DetectionLLDP, SNMP V3
Easy Device ReplacementSupported, based on LLDP
Supported Network Protocols (Other)ARP, HTTP, Ping, SNMP V1, TCP/IP

EtherCAT

OPC UACyclic data read/write, Diagnosis data, Event data
MQTTCyclic data read/write, Diagnosis data, Event data
REST APICyclic data read/write, Diagnosis data, Event data
CoAPCyclic data read/write, Diagnosis data, Event data

IO-Links

ProtocolIO-Link Master
ConnectionM12 5-poles, A-coded
Number of Connections2
Specificationv1.1.3 ready, IEC 61131-9
IO-Link ClassClass A
Transmission Rate / COM ModeCOM1, COM2, COM3
Cycle Time / Update Rate400μs
Parameter Storagesupported

Power Supply

Connection Module Supply VoltageM12 Power, 5-poles, L-coded
Number of Connections2
Current Carrying Capacity of Connectormax. 16 A
Module Supply Voltage (Nominal)24 V DC (SELV/PELV)
Module Supply Voltage (Range)18 V DC to 30 V DC
Current Consumption (typ.)typ. 180mA (at 24 V DC)
Reverse Polarity ProtectionYes
Status Indicator (System Supply)LED green
Diagnostic IndicatorLED red
Connection Sensor Supply VoltageM12 Power, 5-poles, L-coded
Sensor Supply Voltage (Nominal)24 V DC (SELV/PELV)
Sensor Supply Voltage (Range)18 V DC to 30 V DC
Status Indicator (Sensor Supply)LED green
Actuator Supply Voltage (Nominal)24 V DC (SELV/PELV)
Actuator Supply Voltage (Range)18 V DC to 30 V DC
Status Indicator (Actuator Supply)LED green

IO-Link Master Channels

Number of IO-Link Master Channelsmax. 2, configurable
ConnectionM12, 5-poles, A-coded
IO-Link Class A Ports2x, X7 and X8
IO-Link SpecificationV1.1.3
Parameter StorageSupported
Supported COM Modes4.8 kBaud (COM 1), 38.4 kBaud (COM 2), 230.4 kBaud (COM 3)
Cycle Time / Update Ratemin. 1 ms for all channels at 32 Byte IN / OUT
Nominal Voltage24 V DC via US (system power supply)
Nominal Current C/Q (Pin 4)500mA
Nominal Current 1L+ (Pin 1)4A
Perm. Conductor Length to Device≤ 20 m
Status Indicator (IOL)LED green per channel
Diagnostic IndicatorLED red per port

Digital Input Channels

Number of Digital Input Channelsup to 8
ConnectionM12, 5-poles, A-coded
Number of Ports4x, X1 to X4
Channel TypeType 3 acc. to IEC 61131-2
Input Wiring2-, 3-, 4-wire
Nominal Voltage24 V DC via US (module power supply)
Nominal Currenttyp. 3 mA
Sensor Current Supplymax. 1500 mA per port
Sensor TypeP-switching; Type 3 for DI configurations “Without Test Pulse” and Potential-free switches for DI configurations “With Test Pulse”
Input Voltage Range "0" signal-3 V DC ...+5 V DC
Input Voltage Range "1" signal11 V DC ... 30 V DC
Protective CircuitElectronicaly: Overload protection, short-circuit protection
Diagnostic IndicatorLED white or yellow per channel

Digital Output Channels

Number of Digital Output Channels4
ConnectionM12, 5-poles, A-coded
Number of Ports2x, X5 and X6
Channel Typep-switching
Output Wiring2-wire
Nominal Voltage24 V DC via UL
Output Current per Channelmax. 2 A
Output Current per Modulemax. 8 A
Galvanically IsolatedYes
Protective CircuitElectronicaly: Overload protection, short-circuit protection
Overload BehaviorAuto off and on switching / Manual restart
Status Indicator (Outputs)LED white or yellow per channel
Diagnostic IdicatorLED red per channel

Electrical Isolation

US (System Supply Voltage) / FE32V DC (clamp voltage)

Analog Output Channels

US / UL (Actuator Supply Voltage)500 V DC
UL / FE32V DC (clamp voltage)
Bus connection / FE2000 V DC

EMC Conformance

EMC Directive2014/30/EU
EN 61000-4-2 Electrostatic Discharge (ESD)Criterion B; 4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 Electromagnetic FieldCriterion A; Field intensity: 10 V/m
EN 61000-4-4 Fast Transients (Burst)Criterion A, 1 kV; Criterion B/DS, 2 kV
EN 61000-4-5 Surge VoltageCriterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m
EN 61000-4-6 Conducted immunityCriterion A; Test voltage 10 V
EN 55022 Radio Interference PropertiesClass A
EN 55032 Radio Interference PropertiesClass A

Safety & Environmental Compliance

CEYes
RoHS CompliantYes
China RoHS-CompliantYes

Approvals

FS-CertificationTÜV (Rheinland) IEC 61508, ISO 13849
ULcULus Listed, UL 61010-1
CSAYes, via UL
PNOYes
IO-LinkYes

Notes

Protection Degree / IP Rating Note*only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
System Power Supply Connection Note*do not connect / disconnect under voltage!

Resources

Related lion-safety i/o modules