TC EPR(EPCV)/CPE, 3+G C #12+12 Str TC, EPR(EPCV) Ins M4, Blk CPE Jkt, 600V TC-ER 90C Dry/Wet SUN RES DIR BUR

UL Type TC (1277) EPR(EPCV)/CPE, 3+G Conductor 12+12AWG (Class B) Tinned Copper, EPR(EPCV) Insulation M4 Color Code, Black CPE Outer Jacket, 600V TC-ER 90C Dry/Wet SUN RES DIR BUR

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

P03124J is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeOrder
P03124J 0105000ReelOrder online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.65 Revision Date: 02-20-2026

Product Overview

Suitable ApplicationsPower and Control Applications up to 1000V

Construction Details

Overall Cable Diameter (Nominal)0.473 in

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)312 AWG7x20TC - Tinned Copper
Ground Wire112 AWG7x20TC - Tinned Copper

Insulation

ElementSeparatorMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)Conductor(s)XLPE - Cross Linked Polyethylene0.032 in (0.81 mm)0.163 in (4.14 mm)Black and Numbered
Ground WireXLPE - Cross Linked Polyethylene0.032 in (0.81 mm)0.163 in (4.14 mm)Green

Inner Shield

Shield TypeNo Shield

Outer Shield

Shield TypeNo Shield

Outer Jacket

MaterialCPE - Chlorinated Polyethylene
Nom. Thickness0.047 in (1.2 mm)
Nom. Diameter0.473 in
RipcordYes

Electrical Characteristics

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)1.68 Ohm/1000ft30 Amps per Conductor at 30oC
Ground Wire1.75 Ohm/1000ft (5.74 Ohm/km)30 Amps per Conductor at 30oC

Voltage

UL Voltage Rating600 V (TC)

Mechanical Characteristics

Max. Pull Tension347 lbs (157 kg)
Bulk Cable Weight152 lbs/1000ft

Temperature

UL Temperature90°C Dry, 90°C Wet
OperatingWet/Dry: -30°C to 90°C

Bend Radius

Stationary Min.1.892 in (48.06 mm)
Installation Min.2.365 in

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, UV Resistance
SustainabilityCA Prop 65
Flammability / Reaction to FireUL1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, TC-ER, XHHW-2
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)