Belden Store
BeldenA02141O

Product Number: A02141O

TC-ER VN/PVC, 2+G C #14 Str BC, PVC-NYL Ins, E1, 1 C #14 Str BC Ins Grnd, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry 75C Wet SUN RES DIR BUR

UL Type TC-ER (1277) PVC-Nylon/PVC, 2+G Conductor 14AWG (7x22) Bare Copper, PVC-NYL Insulation E1 Color Code, 1 Conductor 14 (7x22) Bare Copper Insulated Ground, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry 75C Wet SUN RES DIR BUR

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

A02141O is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeOrder
A02141O 0105000ReelOrder online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.56 Revision Date: 02-20-2026

Product Overview

Suitable Applicationsharsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Construction Details

Conductor

ElementSizeStrandingMaterial
Conductor(s)147x22BC - Bare Copper
Ground147x22BC - Bare Copper

Insulation

MaterialNom. ThicknessNom. Insulation DiameterColor Code
PVC/Nylon - Polyvinyl Chloride + Nylon0.0225 in (0.572 mm)0.116 in (2.95 mm)Black, White, Green
PVC/Nylon - Polyvinyl Chloride + Nylon0.0225 in (0.572 mm)0.116 in (2.95 mm)

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.047 in (1.2 mm)
Nom. Diameter0.344 in

Electrical Characteristics

Electricals

Nom. Conductor DCR2.52 Ohm/1000ft (8.27 Ohm/km)
Max. Current25 Amps per Conductor at 30oC

Voltage

UL Voltage Rating600 V RMS (Type TC) (TC), 150 V RMS (NPLF) (NPLF)

Mechanical Characteristics

Max. Pull Tension97 lbs (44 kg)
Bulk Cable Weight73 lbs/1000ft (110 kg/km)

Temperature

Operating-30°C to 90°C Dry, +75°C Wet

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
Flammability / Reaction to FireUL1685 UL Loading, 1202
NEC / UL ComplianceArticle 336, NPLF, TC-ER, THWN-2 Singles
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History