Belden Store
Belden62P1603

Product Number: 62P1603

Inst PVC/PVC, 3 Pr #16 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, TC-ER NPLF 90C Dry 75C Wet

UL Instrumentation, 3 Pair 16AWG (7x24) Bare Copper, PVC-NYL Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, Black PVC Outer Jacket, TC-ER NPLF 90C Dry 75C Wet SUN RES DIR BUR

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

62P1603 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeUPCOrder
62P1603 0105000Reel612825359838Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.43 Revision Date: 09-07-2025

Product Overview

Suitable ApplicationsIndustrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, ...), encoders, control circuits, distributed control

Construction Details

Overall Cable Diameter (Nominal)0.504 in

Conductor

ElementPair(s)
No. of Elements3
Size16 AWG
Stranding7x24
MaterialBC - Bare Copper

Insulation

ElementPair(s)
MaterialPVC/Nylon - Polyvinyl Chloride + Nylon
Nom. Thickness0.022
Nom. Insulation Diameter0.101 in (2.57 mm)
Color CodeBlack & White and numbered

Inner Shield

ElementPair(s)
Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type20 AWG (7x28) TC

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type20 AWG (7x28) TC

Outer Jacket

MaterialPVC/Nylon - Polyvinyl Chloride + Nylon
Nom. Thickness0.047 in (1.2 mm)
Nom. Diameter0.504 in
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR7.0 Ohm/1000ft (23 Ohm/km)

Electricals

Nom. Conductor DCR4.2 Ohm/1000ft
Nom. Inner Shield DCR8.2 Ohm/1000ft (27 Ohm/km)
Max. Current15 Amps per Conductor at 25oC

Voltage

UL Voltage Rating600 V (TC-ER), 150 V (NPLF)

Mechanical Characteristics

Max. Pull Tension264 lbs (120 kg)
Bulk Cable Weight126 lbs/1000ft

Temperature

UL TemperatureUL: 75°C Wet, 90°C Dry; NPLF: 90°C
Operating-20°C to +90°C Dry, +75°C Wet

Bend Radius

Stationary Min.6.048 in (153.6 mm)
Installation Min.6.048 in

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
Flammability / Reaction to FireUL1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, Article 760
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)