Belden Store
Belden61T1612

Product Number: 61T1612

Inst, 12 Tri #16 Str BC, PVC-NYL Ins E1, OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry 75C Wet

UL Instrumentation, 12 Triad 16AWG (7x24) Bare Copper, PVC-NYL Insulation E1 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry 75C Wet SUN RES DIR BUR

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

61T1612 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeOrder
61T1612 0104280ReelOrder online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.38 Revision Date: 09-07-2025

Product Overview

Suitable ApplicationsIndustrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, ...), encoders, control circuits, distributed control

Construction Details

Overall Cable Diameter (Nominal)1.021 in

Conductor

ElementTriad(s)
No. of Elements12
Size16 AWG
Stranding7x24
MaterialBC - Bare Copper

Insulation

ElementTriad(s)
MaterialPVC/Nylon - Polyvinyl Chloride + Nylon
Nom. Thickness0.022 in (0.56 mm)
Nom. Insulation Diameter0.101 in (2.57 mm)
Color CodeICEA S-73-732 Table E1: Black & White & Red and Numbered

Inner Shield

MaterialNo Shield

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type20 AWG (7x28) TC

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.074 in (1.9 mm)
Nom. Diameter1.021 in
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR6.14 Ohm/1000ft (20.1 Ohm/km)

Electricals

Nom. Conductor DCR4.2 Ohm/1000ft
Max. Current7 Amps per Conductor at 30oC

Voltage

UL Voltage Rating600 V (TC-ER), 150 V (NPLF)

Mechanical Characteristics

Max. Pull Tension1297 lbs (588.3 kg)
Bulk Cable Weight549 lbs/1000ft

Temperature

UL Temperature90°C Dry, 75°C Wet
Operating-30°C To +90 °C Dry, +75°C Wet

Bend Radius

Stationary Min.12.252 in (311.20 mm)
Installation Min.12.252 in

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
Flammability / Reaction to FireUL1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, Article 760
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesAlternate color coding available upon request.

History

Update and RevisionRevision Number: 0.38 Revision Date: 09-07-2025

Resources

Related tray & tc cable