Inst, 1 Pr #14 Str BC, PVC-NYL Ins E1, OS, Blk PVC Jkt, 600V TC 150V NPLF THHN OR THWN
UL Instrumentation, 1 Pair 14AWG (7x22) Bare Copper, PVC-NYL Insulation E1 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC 150V NPLF THHN OR THWN 90C Dry 75C Wet SUN RES DIR BUR
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
61P1401 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Putup Type | UPC | Order |
|---|---|---|---|
| 61P1401 0105000 | Reel | 612825420262 | Order online |
Specifications
Information
| Put-Up Type | Reel |
|---|---|
| Update and Revision | Revision Number: 0.40 Revision Date: 09-07-2025 |
Product Overview
| Suitable Applications | Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, ...), encoders, control circuits, distributed control |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 0.322 in |
|---|
Conductor
| Element | Pair(s) |
|---|---|
| No. of Elements | 1 |
| Size | 14 AWG |
| Stranding | 7x22 |
| Material | BC - Bare Copper |
Insulation
| Element | Pair(s) |
|---|---|
| Material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Nom. Thickness | 0.020 in (0.51 mm) |
| Nom. Insulation Diameter | 0.111 in (2.82 mm) |
| Color Code | Black, White |
Inner Shield
| Material | No Shield |
|---|
Outer Shield
| Shield Type | Tape |
|---|---|
| Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire Type | 18 AWG (7x26) TC |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Thickness | 0.047 in (1.2 mm) |
| Nom. Diameter | 0.322 in |
| Ripcord | Yes |
Electrical Characteristics
| Nom Outer Shield DCR | 4.83 Ohm/1000ft (15.8 Ohm/km) |
|---|
Electricals
| Nom. Conductor DCR | 2.7 Ohm/1000ft |
|---|---|
| Max. Current | 25 Amps per Conductor at 30oC |
Voltage
| UL Voltage Rating | 600 V (TC), 150 V (NPLF) |
|---|
Mechanical Characteristics
| Max. Pull Tension | 131 lbs (59.4 kg) |
|---|---|
| Bulk Cable Weight | 69 lbs/1000ft |
Temperature
| UL Temperature | 90°C Dry, 75°C Wet |
|---|---|
| Operating | -30°C To +90 °C Dry, +75°C Wet |
Bend Radius
| Stationary Min. | 3.864 in (98.15 mm) |
|---|---|
| Installation Min. | 3.864 in |
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
|---|---|
| Sustainability | CA Prop 65 |
| Flammability / Reaction to Fire | UL1685 UL Loading, IEEE 1202 FT4 |
| NEC / UL Compliance | Article 336, Article 760 |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
Product Notes
| Notes | Alternate color coding available upon request. |
|---|
History
| Update and Revision | Revision Number: 0.40 Revision Date: 09-07-2025 |
|---|
Resources
Related tray & tc cable

1037A
Inst, 3 Pr #16 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet
3 · 16 AWG · BC - Bare Copper · PVC/Nylon - Polyvinyl Chloride + Nylon

1038A
Inst, 50 Pr #18 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, 600V TC 150V NPLF 90C Dry 75C Wet
50 · 18 AWG · BC - Bare Copper · PVC/Nylon - Polyvinyl Chloride + Nylon

1039A
Inst, 4 Pr #16 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet
4 · 16 AWG · BC - Bare Copper · PVC/Nylon - Polyvinyl Chloride + Nylon

1040A
Inst, 6 Pr #16 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet
6 · 16 AWG · BC - Bare Copper · PVC/Nylon - Polyvinyl Chloride + Nylon