TC VN/PVC, 9 C #16 Str BC, PVC-NYL Ins E2, OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR

UL Type TC (1277) PVC-Nylon/PVC, 9 Conductor 16AWG (7x24) Bare Copper, PVC-NYL Insulation E2 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR

Availability
Global
Status
Active
Orderable items
4

Ships from and sold by A5 IT.

Part numbers

28340AS is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeUPCOrder
28340AS 0105000Reel612825365136Order online
28340AS01010000Reel612825330943Order online
28340AS01010000Reel—Order online
28340AS 0105000Reel612825365136Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.192 Revision Date: 04-09-2026

Product Overview

Suitable ApplicationsPower and Control Applications up to 600V

Construction Details

Overall Cable Diameter (Nominal)0.453 in (11.5 mm)

Conductor

ElementConductor(s)
No. of Elements9
Size16 AWG
Stranding7x24
MaterialBC - Bare Copper

Insulation

ElementConductor(s)
MaterialPVC/Nylon - Polyvinyl Chloride + Nylon
Nom. Thickness0.020 in (0.51 mm)
Nom. Insulation Diameter0.099 in (2.5 mm)
Color CodeBlack, Red, Blue, Orange, Yellow, Brown, Red/Black, Blue/Black, Orange/Black

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type16 AWG (7x24) TC

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.047 in (1.2 mm)
Nom. Diameter0.453 in (11.5 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR2.98 Ohm/1000ft (9.78 Ohm/km)

Electricals

Nom. Conductor DCR4.2 Ohm/1000ft
Max. Current12.6 Amps per Conductor at 30oC

Voltage

UL Voltage Rating600 V (TC-ER), 150 V (NPLF)

Mechanical Characteristics

Max. Pull Tension350 lbs (160 kg)
Bulk Cable Weight145 lbs/1000ft

Temperature

UL Temperature90°C Dry, 90°C Wet
OperatingWet/Dry: -30°C to 90°C

Bend Radius

Stationary Min.5.436 in (138.1 mm)
Installation Min.5.436 in (138.1 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
Flammability / Reaction to FireUL1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, Article 400, Article 760, TC-ER, NPLF, TFFN