TC VN/PVC, 4 C #3/0 + GND Str BC, PVC-NYL Ins M4, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet SUN RES DIR BUR
UL Type TC (1277) PVC-Nylon/PVC, 4+G Conductor 3/0+4AWG (Class B) Bare Copper, PVC-NYL Insulation M4 Color Code, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet SUN RES DIR BUR
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
28175A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Putup Type | UPC | Order |
|---|---|---|---|
| 28175A 0102500 | Reel | 612825365471 | Order online |
Specifications
Information
| Put-Up Type | Reel |
|---|---|
| Update and Revision | Revision Number: 0.81 Revision Date: 02-20-2026 |
Product Overview
| Suitable Applications | Power and Control Applications up to 600V; Class 1 Division 2 Hazardous Locations; Recommended Cable Gland Belden BTC200A1741RA |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 1.566 in (39.78 mm) |
|---|
Conductor
| Element | No. of Elements | Size | Stranding | Material | Notes |
|---|---|---|---|---|---|
| Conductor(s) | 4 | 3/0 AWG | 19x10 | BC - Bare Copper | |
| Ground | 1 | 4 AWG | 7x12 | BC - Bare Copper | Uninsulated Bare Copper Ground |
Insulation
| Element | Conductor(s) |
|---|---|
| Material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Nom. Thickness | 0.064 in (1.6 mm) |
| Nom. Insulation Diameter | 0.584 in mm |
| Color Code | Black and Numbered |
Outer Shield
| Material | No Shield |
|---|
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Thickness | 0.085 in (2.2 mm) |
| Nom. Diameter | 1.566 in (39.78 mm) |
| Ripcord | Yes |
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Max. Current |
|---|---|---|
| Conductor(s) | 0.067 Ohm/1000ft (0.22 Ohm/km) | 180 Amps per Conductor at 30oC |
| Ground Wire | 0.26 Ohm/1000ft (0.85 Ohm/km) |
Voltage
| UL Voltage Rating | 600 V |
|---|
Mechanical Characteristics
| Max. Pull Tension | 7980.8 lbs (3620.0 kg) |
|---|---|
| Bulk Cable Weight | 2688 lbs/1000ft (4000 kg/km) |
Temperature
| UL Temperature | 90°C Dry, 90°C Wet |
|---|---|
| Operating | Wet/Dry: -30°C To +90°C |
Bend Radius
| Stationary Min. | 7.83 in (199 mm) |
|---|---|
| Installation Min. | 7.83 in (199 mm) |
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, UV Resistance, Burial |
|---|---|
| Flammability / Reaction to Fire | UL 1685 UL Loading, IEEE 1202 FT4 |
| NEC / UL Compliance | Article 336, TC-ER, THWN-2 |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
History
| Update and Revision | Revision Number: 0.81 Revision Date: 02-20-2026 |
|---|
Resources
Related tray & tc cable

1037A
Inst, 3 Pr #16 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet
3 · 16 AWG · BC - Bare Copper · PVC/Nylon - Polyvinyl Chloride + Nylon

1038A
Inst, 50 Pr #18 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, 600V TC 150V NPLF 90C Dry 75C Wet
50 · 18 AWG · BC - Bare Copper · PVC/Nylon - Polyvinyl Chloride + Nylon

1039A
Inst, 4 Pr #16 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet
4 · 16 AWG · BC - Bare Copper · PVC/Nylon - Polyvinyl Chloride + Nylon

1040A
Inst, 6 Pr #16 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet
6 · 16 AWG · BC - Bare Copper · PVC/Nylon - Polyvinyl Chloride + Nylon