Product Number: 28152A

TC VN/PVC, 2+G C #6+8 Str BC, PVC-NYL Ins M4, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet SUN RES DIR BUR

UL Type TC (1277) PVC-Nylon/PVC, 2+G Conductor 6+8AWG (Class B) Bare Copper, PVC-NYL Insulation M4 Color Code, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet SUN RES DIR BUR

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.52 Revision Date: 01-10-2024

Product Overview

Suitable Applicationsharsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Physical Characteristics (Overall)

Conductor Count2

Conductor

ElementAWGStrandingMaterialNominal DiameterNo. of Conductors
Conductor(s)67x14.5BC - Bare Copper0.179 in2
Ground87x16BC - Bare Copper0.143 in1

Insulation

MaterialNominal Diameter
PVC/Nylon - Polyvinyl Chloride + Nylon0.254 in
No Insulation

Color Chart

NumberColor
1Black
2Black

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nominal Diameter0.634 in
Nominal Wall Thickness0.063 in

Electrical Characteristics

Conductor DCR

Nominal Conductor DCR0.41 Ohm/1000ft

Current

Max. Recommended Current [A]75 Amps per Conductor at 30oC

Voltage

UL DescriptionTC-ER
UL Voltage Rating600 V RMS (Type TC)
Voltage Rating [V]600 V RMS (Type TC)

Temperature Range

UL Temperature Rating90°C Dry, 75°C Wet
Operating Temperature Range-25°C To +90°C

Mechanical Characteristics

UV ResistanceYes
Min Bend Radius (Overall)6.34 in
Minimum Minor Axis Bend Radius2.54 in

Standards

NEC/(UL) ComplianceTC-ER

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
EU CE MarkYes

Suitability

Suitability - BurialYes
Suitability - IndoorYes
Suitability - OutdoorYes
Suitability - Sunlight ResistanceYes

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1685 Vertical Tray Flame Test
IEEE FlammabilityIEEE 1202
UL voltage rating600 V RMS (Type TC)