TC-ER VN/PVC, 4 C #10 Str BC, PVC-NYL Ins E2, OS, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet SUN RES DIR BUR

UL Type TC (1277) PVC-Nylon/PVC, 4 Conductor 10AWG (7x18) Bare Copper, PVC-NYL Insulation E2 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet SUN RES DIR BUR

Availability
Global
Status
Active
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

28140AS is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
28140AS 0105000BlackReel5,000 ftOrder online
28140AS01010000BlackReel10,000 ftOrder online
28140AS01020000BlackReel20,000 ftOrder online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.75 Revision Date: 04-08-2026
FootnoteC - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.

Product Overview

Suitable ApplicationsPower and Control Applications up to 600V

Construction Details

Overall Cable Diameter (Nominal)0.500 in (12.7 mm)

Conductor

ElementConductor(s)
No. of Elements4
Size10 AWG
Stranding7x18
MaterialBC - Bare Copper

Insulation

ElementConductor(s)
MaterialPVC/Nylon - Polyvinyl Chloride + Nylon
Nom. Thickness0.028 in (0.71 mm)
Nom. Insulation Diameter0.166 in mm
Color CodeBlack, Red, Blue, Orange

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.047 in (1.2 mm)
Nom. Diameter0.500 in (12.7 mm)
RipcordYes

Electrical Characteristics

Electricals

Nom. Conductor DCR1.06 Ohm/1000ft
Max. Current32 Amps per conductor at 30°C

Voltage

UL Voltage Rating600 V

Mechanical Characteristics

Max. Pull Tension587.2 lbs (266.3 kg)
Bulk Cable Weight232 lbs/1000ft

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-30°C To +90°C

Bend Radius

Stationary Min.6 in (150 mm)
Installation Min.6 in (150 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, UV Resistance, Burial
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, TC-ER, THWN-2
European Directive ComplianceEU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Plenum NumberICEA S-73-532, S-95-658, S-61-402

History

Update and RevisionRevision Number: 0.75 Revision Date: 04-08-2026
FootnoteC - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.