Belden Store
27641A

Product Number: 27641A

TC VN/PVC, 2 C #12 Str BC, PVC-NYL Ins E2, Blk PVC Jkt, 600V TC 150V NPLF 90C Wet/Dry SUN RES DIR BUR

UL Type TC (1277) PVC-Nylon/PVC, 2 Conductor 12AWG (7x20) Bare Copper, PVC-NYL Insulation E2 Color Code, Black PVC Outer Jacket, 600V TC 150V NPLF 90C Wet/Dry SUN RES DIR BUR

Availability
Global
Status
Active
Orderable items
5

Ships from and sold by A5 IT.

Part numbers

27641A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeUPCOrder
27641A 01010000Reel612825329657Order online
27641A 01010000Reel612825329657Order online
27641A 0102500Reel612825329664Order online
27641A 0105000Reel612825329671Order online
27641A 0105000Reel612825329671Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.476 Revision Date: 04-06-2026

Product Overview

Suitable ApplicationsPower and Control Applications up to 600V; Class 1 Division 2 Hazardous Locations; Recommended Cable Gland Belden BTC075A0551RA

Construction Details

Overall Cable Diameter (Nominal)0.354 in

Conductor

ElementConductor(s)
No. of Elements2
Size12 AWG
Stranding7x20
MaterialBC - Bare Copper

Insulation

ElementConductor(s)
MaterialPVC/Nylon - Polyvinyl Chloride + Nylon
Nom. Thickness0.019 in (0.48 mm)
Nom. Insulation Diameter0.131 in (3.33 mm)
Color CodeBlack, Red

Outer Shield

MaterialNo Shield

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.047 in (1.2 mm)
Nom. Diameter0.354 in
RipcordYes

Electrical Characteristics

Electricals

Nom. Conductor DCR1.68 Ohm/1000ft
Max. Current30 Amps per Conductor at 30oC

Voltage

UL Voltage Rating600 V (TC), 150 V (NPLF)

Mechanical Characteristics

Max. Pull Tension174 lbs (78.9 kg)
Bulk Cable Weight78 lbs/1000ft

Temperature

UL Temperature90°C Dry, 90°C Wet
OperatingWet/Dry: -30°C to 90°C

Bend Radius

Stationary Min.1.416 in (35.97 mm)
Installation Min.1.77 in

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
Flammability / Reaction to FireUL1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, NPLF, TC, THWN-2
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.476 Revision Date: 04-06-2026

Resources