Belden Store
27159A

Product Number: 27159A

TC VN/PVC, 3+G C #2+6 Str BC, PVC-NYL Ins M4, Blk PVC Jkt, 600V TC 90C Dry/Wet SUN RES DIR BUR

UL Type TC (1277) PVC-Nylon/PVC, 3+G Conductor 2+6AWG (7x10+7x14) Bare Copper, PVC-NYL Insulation M4 Color Code, Black PVC Outer Jacket, 600V TC 90C Dry/Wet SUN RES DIR BUR

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

27159A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
27159A 0105000BlackReel5,000 ft612825133353COrder online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.613 Revision Date: 02-20-2026
FootnoteC - CRATE REEL PUT-UP.

Product Overview

Suitable ApplicationsPower and Control Applications up to 600V; Class 1 Division 2 Hazardous Locations; Recommended Cable Gland Belden BTC100A1041RA

Construction Details

Overall Cable Diameter (Nominal)0.987 in

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)32 AWG7x10BC - Bare Copper
Ground Wire16 AWG7x14BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)PVC/Nylon - Polyvinyl Chloride + Nylon0.049 in (1.2 mm)0.381 in (9.68 mm)Black and Numbered
Ground WireNo Insulation

Outer Shield

MaterialNo Shield

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.083 in (2.1 mm)
Nom. Diameter0.987 in
RipcordYes

Electrical Characteristics

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)0.166 Ohm/1000ft130 Amps per Conductor at 30oC
Ground Wire0.47 Ohm/1000ft (1.5 Ohm/km)78 Amps per Conductor at 25oC

Voltage

UL Voltage Rating600 V

Mechanical Characteristics

Max. Pull Tension2781.7 lbs (1261.8 kg)
Bulk Cable Weight942 lbs/1000ft

Temperature

UL Temperature90°C Dry, 75°C Wet
Operating-30°C To +75°C Wet/90°C Dry

Bend Radius

Stationary Min.3.948 in (100.3 mm)
Installation Min.4.935 in

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
Flammability / Reaction to FireUL1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, TC, THHN, THWN
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.613 Revision Date: 02-20-2026
FootnoteC - CRATE REEL PUT-UP.

Resources

Related tray & tc cable