Belden Store
27152A

Product Number: 27152A

TC VN/PVC, 2+G C #6+8 Str BC, PVC-NYL Ins M4, Blk PVC Jkt, 600V TC 90C Dry/Wet SUN RES DIR BUR

UL Type TC (1277) PVC-Nylon/PVC, 2+G Conductor 6+8AWG (7x14+7x16) Bare Copper, PVC-NYL Insulation M4 Color Code, Black PVC Outer Jacket, 600V TC 90C Dry/Wet SUN RES DIR BUR

Availability
Global
Status
Active
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

27152A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeUPCOrder
27152A 0105000Reel612825327851Order online
27152A 0105000Reel612825327851Order online
27152A 01010000Reel612825133292Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.602 Revision Date: 02-20-2026

Product Overview

Suitable ApplicationsPower and Control Applications up to 600V; Class 1 Division 2 Hazardous Locations; Recommended Cable Gland Belden BTC075A0791RA

Construction Details

Overall Cable Diameter (Nominal)0.630 in

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)26 AWG7x14BC - Bare Copper
Ground Wire18 AWG7x16BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)PVC/Nylon - Polyvinyl Chloride + Nylon0.035 in (0.89 mm)0.252 in (6.40 mm)Black and Numbered
Ground WireNo Insulation

Outer Shield

MaterialNo Shield

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.063 in (1.6 mm)
Nom. Diameter0.630 in
RipcordYes

Electrical Characteristics

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)0.42 Ohm/1000ft75 Amps per Conductor at 30oC
Ground Wire0.67 Ohm/1000ft (2.2 Ohm/km)55 Amps per Conductor at 30oC

Voltage

UL Voltage Rating600 V

Mechanical Characteristics

Max. Pull Tension914 lbs (415 kg)
Bulk Cable Weight316 lbs/1000ft

Temperature

UL Temperature90°C Dry, 75°C Wet
OperatingWet/Dry: -30°C To 90°C

Bend Radius

Stationary Min.2.52 in (64.0 mm)
Installation Min.3.15 in

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, UV Resistance, Burial
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, TC, THHN, THWN
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.602 Revision Date: 02-20-2026

Resources

Related tray & tc cable