Fire Alarm, #16-2c BC, Low Capacitance, FPLR
Fire Alarm Cable, Rated-FPLR, 2-16 AWG solid bare copper conductors with Polypropylene insulation, PVC jacket with ripcord
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Suitable Applications | Addressable Fire Alarm Circuits, SLC Loops, Initiating Devices, Digital Audio Loops |
|---|
Construction Details
Conductor
| Element | Pair(s) |
|---|---|
| No. of Pairs | 1 |
| Size | 16 AWG |
| Stranding | Solid |
| Material | BC - Bare Copper |
Insulation
| Material | PP - Polypropylene |
|---|---|
| Nom. Thickness | .018 in (0.46 mm) |
| Nom. Insulation Diameter | .087 in (2.2 mm) |
| Color Code | Black, Red |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Thickness | .030 in (0.76 mm) |
| Nom. Diameter | .234 in (5.94 mm) |
| Ripcord | Yes |
Electrical Characteristics
Electricals
| Nom. Conductor DCR | 3.9 Ohm/1000ft (13 Ohm/km) |
|---|---|
| Nom. Capacitance Cond-to-Cond | 14.5 pF/ft (47.6 pF/m) |
| Nom. Characteristic Impedence | 100 Ohm |
| Max. Current | 6.3 Amps per Conductor at 25oC |
Voltage
| UL Voltage Rating | 300 V |
|---|
Mechanical Characteristics
| Max. Pull Tension | 62 lbs (28 kg) |
|---|---|
| Bulk Cable Weight | 35 lbs/1000ft (52 kg/km) |
Temperature
| UL Temperature | 75°C |
|---|---|
| Operating | -5°C To +75°C |
Bend Radius
| Stationary Min. | 2.3 in (58 mm) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor - Riser, Indoor |
|---|---|
| Flammability / Reaction to Fire | UL 1666 riser, IEC 60332-1-2 |
| CPR Compliance | CPR Euroclass: Eca |
| NEC / UL Compliance | Article 760, FPLR |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Plenum Number | 6220UJ |
History
| Update and Revision | Revision Number: 0.11 Revision Date: 02-21-2024 |
|---|
Resources
Belden 5220UV technical datasheetSafe-T-Line Product BulletinFire Alarm Cable Product BulletinArmored Power-Limited Fire Alarm FPLPSound, Security & Alarm Cable Selection OverviewAccess Control Composite CablesNewGen Cables Product BulletinBelden Low Capacitance Digital Fire Alarm CablesWaterdog Cables Product BulletinDate: 2005-04-01
Related fire alarm cable

26120UL
Armored Fire Alarm, #14-2c BC, FPLP
2 · 14 AWG · BC - Bare Copper · PVC - Polyvinyl Chloride

26220FL
Armored Fire Alarm, #16-2c BC, Shielded, FPLP
2 · 16 AWG · BC - Bare Copper · PVC - Polyvinyl Chloride

26220UL
Armored Fire Alarm, #16-2c BC, FPLP
2 · 16 AWG · BC - Bare Copper · PVC - Polyvinyl Chloride

26320FL
Armored Fire Alarm, #18-2c BC, Shielded, FPLP
2 · 18 AWG · BC - Bare Copper · PVC - Polyvinyl Chloride