Belden Store
5122FL

Product Number: 5122FL

Fire Alarm, #14-4c BC, Shielded, FPLR

Fire Alarm Cable, Riser-FPLR, 4-14 AWG solid bare copper conductors with PVC insulation, overall Beldfoil® shield, PVC jacket with ripcord

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

5122FL is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorUPCOrder
5122FL 0021000Red612825157038Order online

Specifications

Product Overview

Suitable ApplicationsFire Alarm, Monitor/Detection, Circuits: Audio, Control, Initiating, Notification, Noisy Environment

Physical Characteristics (Overall)

Conductor Count4

Conductor

AWG14
StrandingSolid
MaterialBC - Bare Copper
No. of Conductors4

Insulation

MaterialPP - Polypropylene
Nominal Wall Thickness0.01 in

Color Chart

NumberColor
1Black
2Red
3Brown
4Blue

Outer Shield

MaterialBi-Laminate (Alum+Poly)
Material Trade NameBeldfoil®
Coverage [%]100%
Drainwire MaterialTC - Tinned Copper
Drainwire AWG22
Drainwire Construction n x D7x28

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nominal Diameter0.244 in
Nominal Wall Thickness0.017 in
RipcordYes

Construction and Dimensions

Cabling

Twists3.4 twist/ft

Electrical Characteristics

Conductor DCR

Max. Conductor DCR69 Ohm/km
Nominal Conductor DCR2.43 Ohm/1000ft

Capacitance

Nom. Capacitance Conductor to Conductor31 pF/ft
Nom. Capacitance Conductor to Other Conductor to Shield55.9 pF/ft

Current

Max. Recommended Current [A]6.4 Amps per Conductor at 25oC

Voltage

UL Voltage Rating300 V RMS

Temperature Range

UL Temperature Rating75°C
Operating Temperature Range-20°C To +75°C

Mechanical Characteristics

Bulk Cable Weight64 lbs/1000ft
Maximum Recommended Pulling Tension212.8 lbs
Minimum Minor Axis Bend Radius2.5 in

Standards

NEC ArticlesArticle 760
NEC/(UL) ComplianceFPLR
Other SpecificationCalifornia State Fire Marshall

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/96/EC (BFR)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
EU CE MarkYes
MII Order #39 (China RoHS)Yes

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1666 Riser
CSA FlammabilityFT4
UL voltage rating300 V RMS

Plenum/Non-Plenum

Plenum (Y/N)No
Plenum Number6122FL

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

History

Update and RevisionRevision Number: 0.332 Revision Date: 02-03-2025

Resources

Related fire alarm cable