ControlBusTM, Coax RG6, #18 Sol BCCS, FEP Ins, QUAD AL Shld, PVDF Jkt, CMP
ControlBusTM, Coax RG6 18AWG (Solid) Bare Copper Covered Steel, FEP Insulation, Overall Duofoil®+ Aluminum Braid(60%)+Overall Duofoil®+Aluminum Braid(40%) Shield, PVDF Outer Jacket, CMP
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
3132A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Put-Up Type | Length | UPC | Order |
|---|---|---|---|---|---|
| 3132A F2V1000 | Gray, DEC | Reel | 1,000 ft | 612825142065 | Order online |
Specifications
Product Overview
| Suitable Applications | harsh environment, factory automation, ControlNetTM, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications |
|---|
Physical Characteristics (Overall)
| Conductor Count | 1 |
|---|
Conductor
| AWG | 18 |
|---|---|
| Stranding | Solid |
| Material | BCCS - Bare Copper Covered Steel |
| Nominal Diameter | 0.04 in |
| No. of Coax | 1 |
Insulation
| Material | FEP - Fluorinated Ethylene Propylene (Foam) |
|---|---|
| Nominal Diameter | 0.17 in |
Outer Shield
| Type | Layer | Material | Material Trade Name | Coverage [%] |
|---|---|---|---|---|
| Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| Braid | 2 | Aluminum | 60% | |
| Tape | 3 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| Braid | 4 | Aluminum | 40% |
Outer Jacket
| Material | PVDF - Polyvinylidene Fluoride |
|---|---|
| Nominal Diameter | 0.274 in |
Electrical Characteristics
| Electrical Characteristics Notes | Tilt 5 to 10 MHz: .48 dB/100 M |
|---|---|
| Other Electrical Characteristic 2 | Tilt 10 to 20 MHz: .93 dB/100 M |
| Other Electrical Characteristic 3 | Sweep Tested 5 to 400MHz. |
Conductor DCR
| Nominal Conductor DCR | 28 Ohm/1000ft |
|---|---|
| Nominal Outer Shield DCR | 7.2 Ohm/1000ft |
| Outer Conductor DCR | 7.2 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Shield | 16.3 pF/ft |
|---|
Inductance
| Nominal Inductance | 0.093 μH/ft |
|---|
Impedance
| Nominal Characteristic Impedance | 100 Ohm |
|---|---|
| Nominal Characteristic Tolerance | ± 3 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|---|
| 1 MHz | 0.36 dB/100ft |
| 2 MHz | 0.38 dB/100ft |
| 5 MHz | 0.5 dB/100ft |
| 10 MHz | 0.65 dB/100ft |
| 20 MHz | 0.95 dB/100ft |
| 50 MHz | 1.5 dB/100ft |
| 100 MHz | 2.12 dB/100ft |
| 200 MHz | 2.99 dB/100ft |
| 300 MHz | 3.66 dB/100ft |
| 400 MHz | 4.23 dB/100ft |
Delay
| Nominal Delay | 1.2 ns/ft |
|---|---|
| Nominal Velocity of Propagation (VP) [%] | 82% |
Phase Delay Distortion
| f/B | %PDD/100M (5MB) |
|---|---|
| 0.5 | -0.54 |
| 1 | -0.19 |
| 1.5 | 0 |
| 2 | 0.16 |
| 2.5 | 0.3 |
High Frequency
| Frequency [MHz] | Min. SRL (Structural Return Loss) |
|---|---|
| 1 MHz | 23 dB |
| 2 MHz | |
| 5 MHz | |
| 10 MHz | |
| 20 MHz | |
| 50 MHz | |
| 100 MHz | |
| 200 MHz | |
| 300 MHz | |
| 400 MHz |
Voltage
| UL Voltage Rating | 300 V RMS |
|---|
Temperature Range
| UL Temperature Rating | 150°C |
|---|---|
| Operating Temperature Range | -20°C To +150°C |
Mechanical Characteristics
| Bulk Cable Weight | 43 lbs/1000ft |
|---|---|
| Maximum Recommended Pulling Tension | 104 lbs |
| Minimum Minor Axis Bend Radius | 2.75 in |
Standards
| NEC/(UL) Compliance | CMP |
|---|---|
| CEC/C(UL) Compliance | CMP |
| RG Type | 6 |
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV) | Yes |
|---|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| EU CE Mark | Yes |
| MII Order #39 (China RoHS) | Yes |
Suitability
| Suitability - Burial | Yes |
|---|---|
| Suitability - Outdoor | Yes |
Flammability, LS0H, Toxicity Testing
| UL Flammability | NFPA 262 |
|---|---|
| CSA Flammability | FT6 |
| UL voltage rating | 300 V RMS |
Plenum/Non-Plenum
| Plenum (Y/N) | Yes |
|---|
Related Part Numbers
| Non-Plenum Number | 3131A |
|---|---|
| Footnote | C - CRATE REEL PUT-UP. |
Product Notes
| Notes | Tap Marks Every 2.6 Meters to aid in users installation. |
|---|
History
| Update and Revision | Revision Number: 0.418 Revision Date: 02-20-2026 |
|---|
Resources
Related modbus cable

3092A
ControlBusTM, Coax RG-6, #18 Sol BCCS, FPE Ins, QUAD AL Shld, PVC Jkt, CMR
18 AWG · BCCS - Bare Copper Covered Steel · PE - Polyethylene (Foam) · PVC - Polyvinyl Chloride
8 items

3092F
ControlBusTM, Coax RG-6, #20 Str BC, FPE Ins, QUAD AL Shld, PVC Jkt, High Flex, CMR
20 AWG · BC - Bare Copper · PE - Polyethylene (Foam) · PVC - Polyvinyl Chloride
2 items