Key Features
- Suitable Applications: harsh environment, factory automation, ControlNetTM, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications
- Conductor AWG: 18
- Conductor Stranding: Solid
- Conductor Material: BCCS - Bare Copper Covered Steel
- Conductor Nominal Diameter: 0.04 in
- Conductor No. of Coax: 1
- Insulation Material: FEP - Fluorinated Ethylene Propylene (Foam)
- Insulation Nominal Diameter: 0.17 in
Belden 3132A F2V1000 is an orderable item number in the Belden 3132A family (Cable › Fieldbus Cable › Modbus Cable). ControlBusTM, Coax RG6 18AWG (Solid) Bare Copper Covered Steel, FEP Insulation, Overall Duofoil®+ Aluminum Braid(60%)+Overall Duofoil®+Aluminum Braid(40%) Shield, PVDF Outer Jacket, CMP This item: Color Gray, DEC, Put-Up Type Reel, Length 1,000 ft, UPC 612825142065. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.418 Revision Date: 02-20-2026 |
Standards
| RG Type | 6 |
| NEC/(UL) Compliance | CMP |
| CEC/C(UL) Compliance | CMP |
This Item
| UPC | 612825142065 |
| Color | Gray, DEC |
| Length | 1,000 ft |
| Item Number | 3132A F2V1000 |
| Put-Up Type | Reel |
Suitability
| Suitability - Burial | Yes |
| Suitability - Outdoor | Yes |
Product Notes
| Notes | Tap Marks Every 2.6 Meters to aid in users installation. |
Product Overview
| Suitable Applications | harsh environment, factory automation, ControlNetTM, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications |
Plenum/Non-Plenum
| Plenum (Y/N) | Yes |
Temperature Range
| UL Temperature Rating | 150°C |
| Operating Temperature Range | -20°C To +150°C |
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
| Non-Plenum Number | 3131A |
Electrical Characteristics
| Delay — Nominal Delay | 1.2 ns/ft |
| Voltage — UL Voltage Rating | 300 V RMS |
| Electrical Characteristics Notes | Tilt 5 to 10 MHz: .48 dB/100 M |
| Inductance — Nominal Inductance | 0.093 μH/ft |
| Other Electrical Characteristic 2 | Tilt 10 to 20 MHz: .93 dB/100 M |
| Other Electrical Characteristic 3 | Sweep Tested 5 to 400MHz. |
| Phase Delay Distortion Row 1 — F/B | 0.5 |
| Phase Delay Distortion Row 2 — F/B | 1 |
| Phase Delay Distortion Row 3 — F/B | 1.5 |
| Phase Delay Distortion Row 4 — F/B | 2 |
| Phase Delay Distortion Row 5 — F/B | 2.5 |
| Conductor DCR — Outer Conductor DCR | 7.2 Ohm/1000ft |
| Conductor DCR — Nominal Conductor DCR | 28 Ohm/1000ft |
| High Frequency Row 1 — Frequency [MHz] | 1 MHz |
| High Frequency Row 2 — Frequency [MHz] | 2 MHz |
| High Frequency Row 3 — Frequency [MHz] | 5 MHz |
| High Frequency Row 4 — Frequency [MHz] | 10 MHz |
| High Frequency Row 5 — Frequency [MHz] | 20 MHz |
| High Frequency Row 6 — Frequency [MHz] | 50 MHz |
| High Frequency Row 7 — Frequency [MHz] | 100 MHz |
| High Frequency Row 8 — Frequency [MHz] | 200 MHz |
| High Frequency Row 9 — Frequency [MHz] | 300 MHz |
| High Frequency Row 10 — Frequency [MHz] | 400 MHz |
| Conductor DCR — Nominal Outer Shield DCR | 7.2 Ohm/1000ft |
| Impedance — Nominal Characteristic Impedance | 100 Ohm |
| Impedance — Nominal Characteristic Tolerance | ± 3 Ohm |
| Phase Delay Distortion Row 1 — %PDD/100M (5MB) | -0.54 |
| Phase Delay Distortion Row 2 — %PDD/100M (5MB) | -0.19 |
| Phase Delay Distortion Row 3 — %PDD/100M (5MB) | 0 |
| Phase Delay Distortion Row 4 — %PDD/100M (5MB) | 0.16 |
| Phase Delay Distortion Row 5 — %PDD/100M (5MB) | 0.3 |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 82% |
| Capacitance — Nom. Capacitance Conductor To Shield | 16.3 pF/ft |
| High Frequency (Nominal/Typical) Row 1 — Frequency [MHz] | 1 MHz |
| High Frequency (Nominal/Typical) Row 2 — Frequency [MHz] | 2 MHz |
| High Frequency (Nominal/Typical) Row 3 — Frequency [MHz] | 5 MHz |
| High Frequency (Nominal/Typical) Row 4 — Frequency [MHz] | 10 MHz |
| High Frequency (Nominal/Typical) Row 5 — Frequency [MHz] | 20 MHz |
| High Frequency (Nominal/Typical) Row 6 — Frequency [MHz] | 50 MHz |
| High Frequency (Nominal/Typical) Row 7 — Frequency [MHz] | 100 MHz |
| High Frequency (Nominal/Typical) Row 8 — Frequency [MHz] | 200 MHz |
| High Frequency (Nominal/Typical) Row 9 — Frequency [MHz] | 300 MHz |
| High Frequency Row 1 — Min. SRL (Structural Return Loss) | 23 dB |
| High Frequency (Nominal/Typical) Row 10 — Frequency [MHz] | 400 MHz |
| High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss | 0.36 dB/100ft |
| High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss | 0.38 dB/100ft |
| High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss | 0.5 dB/100ft |
| High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss | 0.65 dB/100ft |
| High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss | 0.95 dB/100ft |
| High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss | 1.5 dB/100ft |
| High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss | 2.12 dB/100ft |
| High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss | 2.99 dB/100ft |
| High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss | 3.66 dB/100ft |
| High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss | 4.23 dB/100ft |
Mechanical Characteristics
| Bulk Cable Weight | 43 lbs/1000ft |
| Minimum Minor Axis Bend Radius | 2.75 in |
| Maximum Recommended Pulling Tension | 104 lbs |
Physical Characteristics (Overall)
| Conductor Count | 1 |
| Conductor — AWG | 18 |
| Conductor — Material | BCCS - Bare Copper Covered Steel |
| Conductor — Stranding | Solid |
| Insulation — Material | FEP - Fluorinated Ethylene Propylene (Foam) |
| Conductor — No. Of Coax | 1 |
| Outer Jacket — Material | PVDF - Polyvinylidene Fluoride |
| Outer Shield Row 1 — Type | Tape |
| Outer Shield Row 2 — Type | Braid |
| Outer Shield Row 3 — Type | Tape |
| Outer Shield Row 4 — Type | Braid |
| Outer Shield Row 1 — Layer | 1 |
| Outer Shield Row 2 — Layer | 2 |
| Outer Shield Row 3 — Layer | 3 |
| Outer Shield Row 4 — Layer | 4 |
| Conductor — Nominal Diameter | 0.04 in |
| Insulation — Nominal Diameter | 0.17 in |
| Outer Shield Row 1 — Material | Tri-Laminate (Alum+Poly+Alum) |
| Outer Shield Row 2 — Material | Aluminum |
| Outer Shield Row 3 — Material | Tri-Laminate (Alum+Poly+Alum) |
| Outer Shield Row 4 — Material | Aluminum |
| Outer Jacket — Nominal Diameter | 0.274 in |
| Outer Shield Row 1 — Coverage [%] | 100% |
| Outer Shield Row 2 — Coverage [%] | 60% |
| Outer Shield Row 3 — Coverage [%] | 100% |
| Outer Shield Row 4 — Coverage [%] | 40% |
| Outer Shield Row 1 — Material Trade Name | Duofoil® |
| Outer Shield Row 3 — Material Trade Name | Duofoil® |
Flammability, LS0H, Toxicity Testing
| UL Flammability | NFPA 262 |
| CSA Flammability | FT6 |
| UL Voltage Rating | 300 V RMS |
Applicable Environmental And Other Programs
| EU CE Mark | Yes |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |