Belden Store
Belden 3132A F2V1000 — ControlBusTM, Coax RG6, #18 Sol BCCS, FEP Ins, QUAD AL Shld, PVDF Jkt, CMP

Belden Cable

Belden|

MPN: 3132A F2V1000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 3132A F2V1000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: harsh environment, factory automation, ControlNetTM, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications
  • Conductor AWG: 18
  • Conductor Stranding: Solid
  • Conductor Material: BCCS - Bare Copper Covered Steel
  • Conductor Nominal Diameter: 0.04 in
  • Conductor No. of Coax: 1
  • Insulation Material: FEP - Fluorinated Ethylene Propylene (Foam)
  • Insulation Nominal Diameter: 0.17 in
Belden 3132A F2V1000 is an orderable item number in the Belden 3132A family (Cable › Fieldbus Cable › Modbus Cable). ControlBusTM, Coax RG6 18AWG (Solid) Bare Copper Covered Steel, FEP Insulation, Overall Duofoil®+ Aluminum Braid(60%)+Overall Duofoil®+Aluminum Braid(40%) Shield, PVDF Outer Jacket, CMP This item: Color Gray, DEC, Put-Up Type Reel, Length 1,000 ft, UPC 612825142065. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.418 Revision Date: 02-20-2026

Standards

RG Type6
NEC/(UL) ComplianceCMP
CEC/C(UL) ComplianceCMP

This Item

UPC612825142065
ColorGray, DEC
Length1,000 ft
Item Number3132A F2V1000
Put-Up TypeReel

Suitability

Suitability - BurialYes
Suitability - OutdoorYes

Product Notes

NotesTap Marks Every 2.6 Meters to aid in users installation.

Product Overview

Suitable Applicationsharsh environment, factory automation, ControlNetTM, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications

Plenum/Non-Plenum

Plenum (Y/N)Yes

Temperature Range

UL Temperature Rating150°C
Operating Temperature Range-20°C To +150°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.
Non-Plenum Number3131A

Electrical Characteristics

Delay — Nominal Delay1.2 ns/ft
Voltage — UL Voltage Rating300 V RMS
Electrical Characteristics NotesTilt 5 to 10 MHz: .48 dB/100 M
Inductance — Nominal Inductance0.093 μH/ft
Other Electrical Characteristic 2Tilt 10 to 20 MHz: .93 dB/100 M
Other Electrical Characteristic 3Sweep Tested 5 to 400MHz.
Phase Delay Distortion Row 1 — F/B0.5
Phase Delay Distortion Row 2 — F/B1
Phase Delay Distortion Row 3 — F/B1.5
Phase Delay Distortion Row 4 — F/B2
Phase Delay Distortion Row 5 — F/B2.5
Conductor DCR — Outer Conductor DCR7.2 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR28 Ohm/1000ft
High Frequency Row 1 — Frequency [MHz]1 MHz
High Frequency Row 2 — Frequency [MHz]2 MHz
High Frequency Row 3 — Frequency [MHz]5 MHz
High Frequency Row 4 — Frequency [MHz]10 MHz
High Frequency Row 5 — Frequency [MHz]20 MHz
High Frequency Row 6 — Frequency [MHz]50 MHz
High Frequency Row 7 — Frequency [MHz]100 MHz
High Frequency Row 8 — Frequency [MHz]200 MHz
High Frequency Row 9 — Frequency [MHz]300 MHz
High Frequency Row 10 — Frequency [MHz]400 MHz
Conductor DCR — Nominal Outer Shield DCR7.2 Ohm/1000ft
Impedance — Nominal Characteristic Impedance100 Ohm
Impedance — Nominal Characteristic Tolerance± 3 Ohm
Phase Delay Distortion Row 1 — %PDD/100M (5MB)-0.54
Phase Delay Distortion Row 2 — %PDD/100M (5MB)-0.19
Phase Delay Distortion Row 3 — %PDD/100M (5MB)0
Phase Delay Distortion Row 4 — %PDD/100M (5MB)0.16
Phase Delay Distortion Row 5 — %PDD/100M (5MB)0.3
Delay — Nominal Velocity Of Propagation (VP) [%]82%
Capacitance — Nom. Capacitance Conductor To Shield16.3 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]2 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]5 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]20 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]50 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]200 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]300 MHz
High Frequency Row 1 — Min. SRL (Structural Return Loss)23 dB
High Frequency (Nominal/Typical) Row 10 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.36 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss0.38 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss0.5 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss0.65 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss0.95 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss1.5 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss2.12 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss2.99 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss3.66 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss4.23 dB/100ft

Mechanical Characteristics

Bulk Cable Weight43 lbs/1000ft
Minimum Minor Axis Bend Radius2.75 in
Maximum Recommended Pulling Tension104 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG18
Conductor — MaterialBCCS - Bare Copper Covered Steel
Conductor — StrandingSolid
Insulation — MaterialFEP - Fluorinated Ethylene Propylene (Foam)
Conductor — No. Of Coax1
Outer Jacket — MaterialPVDF - Polyvinylidene Fluoride
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 3 — TypeTape
Outer Shield Row 4 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Outer Shield Row 3 — Layer3
Outer Shield Row 4 — Layer4
Conductor — Nominal Diameter0.04 in
Insulation — Nominal Diameter0.17 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialAluminum
Outer Shield Row 3 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 4 — MaterialAluminum
Outer Jacket — Nominal Diameter0.274 in
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]60%
Outer Shield Row 3 — Coverage [%]100%
Outer Shield Row 4 — Coverage [%]40%
Outer Shield Row 1 — Material Trade NameDuofoil®
Outer Shield Row 3 — Material Trade NameDuofoil®

Flammability, LS0H, Toxicity Testing

UL FlammabilityNFPA 262
CSA FlammabilityFT6
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

EU CE MarkYes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account