ControlBusTM, Coax RG-11, #14 Sol BCCS, FPE Ins, QUAD AL Shld, PVC Jkt, CMR
Coax RG-11 14AWG (Solid) Bare Copper Covered Steel, Foam PE Insulation, Overall Duobond® II+ Aluminum Braid(60%)+Duofoil®+Aluminum Braid(40%) Shield, PVC Outer Jacket, CMR
- Availability
- Global
- Status
- Active
- Orderable items
- 3
Part numbers
3094A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | Length | UPC | Order |
|---|---|---|---|---|---|
| 3094A F2V500 | Gray, DEC | Reel | 500 ft | 612825141525 | Order online |
| 3094A F2V1000 | Gray, DEC | Reel | 1,000 ft | 612825141501 | Order online |
| 3094A F2V2000 | Gray, DEC | Reel | 2,000 ft | 612825141518 | Order online |
Specifications
Product Overview
| Suitable Applications | Harsh environment, factory automation, ControlNetTM, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications |
|---|
Construction Details
| RG Type | 11 |
|---|---|
| Overall Cable Diameter (Nominal) | 0.407 in (10.3 mm) |
Conductor
| Size | 14 AWG |
|---|---|
| Stranding | Solid |
| Nom. Diameter | 0.064 in |
| Material | BCCS - Bare Copper Covered Steel |
Insulation
| Material | PE - Polyethylene (Foam) |
|---|---|
| Nom. Insulation Diameter | 0.280 in (7.11 mm) |
| Color Code | White |
| Notes | Gas Injected |
Outer Shield
| Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
|---|---|---|---|---|
| 1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duobond® II | 100% |
| 2 | Braid | Aluminum | 60% | |
| 3 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| 4 | Braid | Aluminum | 40% |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Diameter | 0.407 in (10.3 mm) |
Electrical Characteristics
Return Loss
| Frequency | 5 - 400 MHz |
|---|---|
| Min. Structural Return Loss | 20 dB |
Attenuation
| Frequency | Nom. Attenuation |
|---|---|
| 1 MHz | 0.16 dB/100ft |
| 2 MHz | 0.18 dB/100ft |
| 5 MHz | 0.26 dB/100ft |
| 10 MHz | 0.38 dB/100ft |
| 20 MHz | 0.55 dB/100ft |
| 50 MHz | 0.83 dB/100ft |
| 100 MHz | 1.17 dB/100ft |
| 200 MHz | 1.60 dB/100ft |
| 300 MHz | 1.99 dB/100ft |
| 400 MHz | 2.30 dB/100ft |
Electricals
| Nom. Conductor DCR | 11.5 Ohm/1000ft |
|---|---|
| Nom. Outer Shield DCR | 1.8 Ohm/1000ft (5.9 Ohm/km) |
| Nom. Capacitance Cond-to-Shield | 16.3 pF/ft (53.5 pF/m) |
| Nom. Characteristic Impedance | 75 Ohm |
| Nom. Velocity of Prop. | 83% |
Voltage
| UL Voltage Rating | 300 V (CMR, CMG) |
|---|
Mechanical Characteristics
| Max. Pull Tension | 234 lbs (106 kg) |
|---|---|
| Bulk Cable Weight | 60 lbs/1000ft |
Temperature
| UL Temperature | 75°C |
|---|---|
| Operating | -30°C to 75°C |
Bend Radius
| Installation Min. | 4 in (100 mm) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor - Plenum, Indoor, Outdoor, Sunlight Resistance, Aerial - When supported by messenger wire |
|---|---|
| Sustainability | CA Prop 65 |
| Flammability / Reaction to Fire | UL 1666 Riser |
| CPR Compliance | CPR Euroclass: Eca |
| NEC / UL Compliance | CMR, CL2R |
| CEC / C(UL) Compliance | CMG. |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK Regulation Compliance | UKCA Mark |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Plenum Number | 3095A |
Product Notes
| Notes | Tap marks every 2.6 meters to aid users in installation. |
|---|
History
| Update and Revision | Revision Number: 0.516 Revision Date: 02-20-2026 |
|---|---|
| Footnote | C - CRATE REEL PUT-UP. |
Resources
Related controlnet cable

123092A
ControlBusTM, Coax RG6, #18 Sol BCCS, PO Ins, QUAD AL Shld, PVC Jkt, AIA Armor, PVC Jkt, CM
18 AWG · BCCS - Bare Copper Covered Steel · PE - Polyethylene (Foam) · PVC - Polyvinyl Chloride

3092T
ControlBusTM, Coax RG6, #18 Sol BCCS, PO Ins, QUAD AL Shld, LSZH Jkt, CMG
18 · BCCS - Bare Copper Covered Steel · PE - Polyethylene (Foam) · PE - Polyethylene

3095A
ControlBusTM, Coax RG11, #14 Sol BCCS, FEP Ins, QUAD AL Shld, PVDF Jkt, CMP
BCCS - Bare Copper Covered Steel · FEP - Fluorinated Ethylene Propylene (Foam) · PVDF - Polyvinylidene Fluoride · 300 V RMS

3131A
ControlBusTM, Coax RG6, #18 Sol BCCS, PO Ins, QUAD AL Shld, PVC Jkt, CMR
BCCS - Bare Copper Covered Steel · PE - Polyethylene (Foam) · PVC - Polyvinyl Chloride