Belden Store
70102E

Product Number: 70102E

Profibus DP, 1PR #22 Str BC, PO ins, F/B, PVC jkt,

Profibus DP, 1 Pair AWG 22 Bare Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Foil + Braid(s) shielding, PVC jacket

Availability
EMEA
Status
Active
Orderable items
6

Ships from and sold by A5 IT.

Part numbers

70102E is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthEANOrder
70102E.00500PurpleReel500 m8719605012180Order online
70102E.K0500PurpleReel500 m8719605012210Order online
70102E.01500PurpleReel500 m8719605012203Order online
70102E.K1500PurpleReel500 m8719605012227Order online
70102E.001000PurpleReel1,000 m8719605012173Order online
70102E.011000PurpleReel1,000 m8719605012197Order online

Specifications

Product Overview

Suitable ApplicationsInstrumentation and computer cable; For data transmission applications such as Profibus DP

Construction Details

Conductor

Size22
Stranding7x30
MaterialBC - Bare Copper

Insulation

MaterialPE - Polyethylene (Foam)
Nom. Insulation Diameter2.55 mm (0.100 in)
Color CodeRed & Green

Outer Shield

Shield TypeMaterialCoverage
TapeBi-Laminate (Alum+Poly)65%
BraidTinned Copper (TC)65%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Diameter8 mm

Electrical Characteristics

Electricals

Nom. Conductor DCR57 Ohm/km (17 Ohm/1000ft)
Nom. Capacitance Cond-to-Cond28 pF/m (8.5 pF/ft)
Nom. Characteristic Impedence150 Ohm

Mechanical Characteristics

Temperature

Installation-15°C To +70°C
Storage-40°C to +70°C

Bend Radius

Installation Min.80 mm

Standards and Compliance

Environmental SuitabilityIndoor
Flammability / Reaction to FireIEC 60332-1-2
CPR ComplianceCPR Euroclass: Eca; CPR UKCA Class: Eca
UK Regulation ComplianceUKCA Mark

History

Update and RevisionRevision Number: 0.187 Revision Date: 02-20-2026

Resources

Related armored data cable