DataTuff Ind. Cat. 6A OSP Cable, 4 Pair, F/UTP, Gel Filled, 23AWG. Oil Res II
DataTuff Industrial Category 6A Cable (500MHz), OSP Rated, 4 Pair, 23 AWG Solid Bare Copper Conductors, F/UTP, Inner LLDPE Jacket, Shield, Gel-Filled, Outer CPE Jacket
- Availability
- Americas
- Status
- Active
Specifications
Product Overview
| Suitable Applications | OSP-Outside Plant, Premise Horizontal Cable, Ethernet up to 10GBASE-T, Wi-Fi 6, Wi-Fi 5, PoE++, PoE+, PoE, HDBaseT |
|---|---|
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents . |
Construction Details
| Waterblocking | Gel Filled |
|---|---|
| Overall Cable Diameter (Nominal) | 0.360 in (9.14 mm) |
Conductor
| Size | 23 |
|---|---|
| Stranding | Solid |
| Material | BC - Bare Copper |
| No. of Pairs | 4 |
Insulation
| Material | PO - Polyolefin |
|---|---|
| Color Code | White & Blue, White & Orange, White & Green, White & Brown |
Inner Jacket
| Material | PE - Polyethylene |
|---|---|
| Nom. Diameter | 0.26 in (6.6 mm) |
Outer Shield
| Shield Type | Tape |
|---|---|
| Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire Type | 26 AWG (7x34) TC |
Outer Jacket
| Material | CPE - Chlorinated Polyethylene |
|---|---|
| Nom. Diameter | 0.360 in (9.14 mm) |
| Ripcord | Yes |
Electrical Characteristics
Electricals
| Max. Conductor DCR | 82 Ohm/km (25 Ohm/1000ft) |
|---|---|
| Max. Capacitance Unbalance | 45 pF/100m |
Delay
| Frequency | 100 MHz |
|---|---|
| Max. Delay Skew | 45 ns/100m |
| Nom. Velocity of Prop. | 64% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) [dB/100m] | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) | Max./Min. Fitted Impedance | Min. PSANEXT [dB] | Min. PSAACRF [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2.1 | 74.3 | 72.3 | 72.2 | 70.2 | 67.8 | 64.8 | 20.0 | 105 +/- 10 | 115 +/- 15 | 67.0 | 67.0 | 40.0 | 35.0 |
| 4 | 3.8 | 65.3 | 63.3 | 61.5 | 59.5 | 55.8 | 52.8 | 23.0 | 105 +/- 10 | 100 +/- 7 | 67.0 | 66.2 | 40.0 | 23.0 |
| 8 | 5.3 | 60.8 | 58.8 | 55.4 | 53.4 | 49.7 | 46.7 | 24.5 | 100 +/- 22 | 100 +/- 7 | 67.0 | 60.1 | 40.0 | 16.9 |
| 10 | 5.9 | 59.3 | 57.3 | 53.4 | 51.4 | 47.8 | 44.8 | 25.0 | 100 +/- 22 | 100 +/- 7 | 67.0 | 58.2 | 40.0 | 15.0 |
| 16 | 7.5 | 56.2 | 54.2 | 48.8 | 46.8 | 43.7 | 40.7 | 25.0 | 100 +/- 22 | 100 +/- 7 | 67.0 | 54.1 | 38.0 | 10.9 |
| 20 | 8.4 | 54.8 | 52.8 | 46.4 | 44.4 | 41.8 | 38.8 | 25.0 | 100 +/- 22 | 100 +/- 7 | 67.0 | 52.2 | 37.0 | 9.0 |
| 25 | 9.4 | 53.3 | 51.3 | 44.0 | 42.0 | 39.8 | 36.8 | 24.3 | 100 +/- 22 | 100 +/- 7 | 67.0 | 50.2 | 36.0 | 7.0 |
| 31.25 | 10.5 | 51.9 | 49.9 | 41.4 | 39.4 | 37.9 | 34.9 | 23.6 | 100 +/- 22 | 100 +/- 7 | 67.0 | 48.3 | 35.1 | 5.1 |
| 62.5 | 15.0 | 47.4 | 45.4 | 32.4 | 30.4 | 31.9 | 28.9 | 21.5 | 100 +/- 22 | 100 +/- 7 | 65.6 | 42.3 | 32.0 | |
| 100 | 19.1 | 44.3 | 42.3 | 25.2 | 23.2 | 27.8 | 24.8 | 20.1 | 100 +/- 22 | 100 +/- 7 | 62.5 | 38.2 | 30.0 | |
| 200 | 27.6 | 39.8 | 37.8 | 12.2 | 10.2 | 21.8 | 18.8 | 18.0 | 100 +/- 22 | 100 +/- 7 | 58.0 | 32.2 | 27.0 | |
| 250 | 31.1 | 38.3 | 36.3 | 7.3 | 5.3 | 19.8 | 16.8 | 17.3 | 100 +/- 32 | 100 +/- 7 | 56.5 | 30.2 | 26.0 | |
| 300 | 34.3 | 37.1 | 35.1 | 2.9 | 0.9 | 18.3 | 15.3 | 16.8 | 100 +/- 32 | 100 +/- 7 | 55.3 | 28.7 | 25.2 | |
| 350 | 37.2 | 36.1 | 34.1 | 16.9 | 13.9 | 16.3 | 100 +/- 32 | 100 +/- 7 | 54.3 | 27.3 | 24.6 | |||
| 400 | 40.1 | 35.3 | 33.3 | 15.8 | 12.8 | 15.9 | 100 +/- 32 | 100 +/- 7 | 53.5 | 26.2 | 24.0 | |||
| 450 | 42.7 | 34.5 | 32.5 | 14.7 | 11.7 | 15.5 | 100 +/- 32 | 100 +/- 7 | 52.7 | 25.1 | 23.5 | |||
| 500 | 45.3 | 33.8 | 31.8 | 13.8 | 10.8 | 15.2 | 100 +/- 32 | 100 +/- 7 | 52.0 | 24.2 | 23.0 |
Voltage
| Voltage Rating | 300 V |
|---|
Mechanical Characteristics
| Max. Pull Tension | 25 lbs (11 kg) |
|---|---|
| Bulk Cable Weight | 49 lbs/1000ft (73 kg/km) |
Temperature
| Operating | -40°C To +75°C |
|---|---|
| Installation | -40°C To +60°C |
| Storage | -40°C To +75°C |
Bend Radius
| Stationary Min. | 3.0 in (76 mm) |
|---|---|
| Installation Min. | 3.75 in (95.3 mm) |
Standards and Compliance
| Environmental Suitability | Outdoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance, Aerial - When supported by messenger wire |
|---|---|
| CPR Compliance | CPR Euroclass: Fca; CPR UKCA Class: Fca |
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
| Data Category | Category 6A |
| TIA/EIA Compliance | ANSI/TIA-568.2-E Category 6A |
| ISO/IEC Compliance | 11801 ed 2.2 (2011) Class EA |
| CENELEC Compliance | Segregation class according EN50174-2 = a |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2017-07-10 |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Cable not guaranteed to meet TIA 568.2 specification for delay above lengths of 90m. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Fully Water Blocked. Suitable for burial or use in outdoor wet locations. Not recommended for Direct Burial applications without additional crush and impact protection. Additional crush and impact protection would include cable armoring, installation in conduit or installation with over top barriers per Belden Technical Bulletin T/8-6. Belden recommends using an entrance demarcation point when transitioning inside buildings with gel-filled OSP cables due to the cable design containing gel specific for wet outdoor environments. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1. |
|---|
History
| Update and Revision | Revision Number: 0.26 Revision Date: 08-19-2026 |
|---|
Resources
Belden IEA009 technical datasheet10GXM13 Category 6A Cable - Product BulletinDataTuff Fiber Optic Renewable Grade Cable10GXS Cable Product Bulletin10GXW Cable Product BulletinDataTuff Cat 6A High Flex Industrial Ethernet CableCopper CatalogBlade Slot Selection TableBelden Cable Prep Tool InstructionsDate: 2016-03-02
Related category 6a cable

10GA22
CAT 6A 4P 23AWG, U/UTP, LSZH Jkt, Indoor
23 · BC - Bare Copper · PE - Polyethylene · LSZH - Low Smoke Zero Halogen (Flame Retardant)
8 items

10GA24
CAT 6A 4P 23AWG, U/UTP, LSZH Jkt, Indoor
23 · BC - Bare Copper · PE - Polyethylene · LSZH - Low Smoke Zero Halogen (Flame Retardant)
9 items

10GA25
10GA25 Cat 6A Cable, F/UTP, LSZH, 4 Pair, AWG 23, Indoor
23 · BC - Bare Copper · PE - Polyethylene · LSZH - Low Smoke Zero Halogen (Flame Retardant)
8 items

10GAB1
CAT 6A 23AWG, U/UTP, LSZH Jkt, GB 31247 B1 Rating, Indoor
23 · BC - Bare Copper · PE - Polyethylene · LSZH - Low Smoke Zero Halogen (Flame Retardant)
5 items