DataTuff® 6A, 4 Bonded-Pr #22 Sol BC, PO Ins, X-spline, PVC Jkt, OS+TC Brd, PVC Jkt, PLTC, CMR, CMX Outdoor
Industrial Ethernet Cat 6A, 4 Bonded-Pair 22AWG (Solid) Bare Copper, PO Insulation, X-spline, PVC Inner Jacket, Overall Beldfoil®+Tinned Copper Braid(80%) Shield, PVC Outer Jacket, PLTC, CMR, CMX Outdoor
- Availability
- Americas
- Status
- Active
Specifications
Product Overview
| Suitable Applications | Industrial Ethernet Cat 6, 4 Bonded-Pair 22AWG (Solid) Bare Copper, PO Insulation, X-spline, PVC Inner Jacket, Overall Beldfoil®+Tinned Copper Braid(80%) Shield, PVC Outer Jacket, PLTC, CMR, CMX Outdoor |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 0.425 in (10.8 mm) |
|---|
Conductor
| Material | BC - Bare Copper |
|---|---|
| No. of Pairs | BC - Bare Copper (v799780) |
Insulation
| Nom. Insulation Diameter | PO - Polyolefin (687467) mm |
|---|---|
| Color Code | White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown |
Inner Jacket
| Nom. Diameter | PVC - Polyvinyl Chloride (687384) |
|---|
Outer Shield
| Shield Type | Material | Coverage |
|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% |
| Braid | Tinned Copper (TC) | 80% |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Diameter | 0.425 in (10.8 mm) |
| Ripcord | No |
Electrical Characteristics
Electricals
| Max. Conductor DCR | 56.5 Ohm/km (17.2 Ohm/1000ft) |
|---|---|
| Max. Capacitance Unbalance | 330 pF/100m |
Delay
| Frequency | 100 MHz |
|---|---|
| Max. Delay | 537.6 ns/100m |
| Max. Delay Skew | 45 ns/100m |
| Nom. Velocity of Prop. | 68% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) [dB/100m] | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. PSANEXT [dB] | Min. PSAACRF [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2.1 | 74.3 | 72.3 | 72.3 | 70.3 | 67.8 | 64.8 | 20.0 | 67.0 | 67.0 | 40.0 | 35.0 |
| 4 | 3.8 | 65.3 | 63.3 | 61.5 | 59.5 | 55.8 | 52.8 | 23.0 | 67.0 | 66.2 | 40.0 | 23.0 |
| 8 | 5.3 | 60.8 | 58.8 | 55.4 | 53.4 | 49.7 | 46.7 | 24.5 | 40 | 16.9 | ||
| 10 | 5.9 | 59.3 | 57.3 | 53.4 | 51.4 | 47.8 | 44.8 | 25.0 | 67.0 | 58.2 | 40.0 | 15.0 |
| 16 | 7.5 | 56.2 | 54.2 | 48.8 | 46.8 | 43.7 | 40.7 | 25.0 | 38.0 | 10.9 | ||
| 20 | 8.4 | 54.8 | 52.8 | 46.4 | 44.4 | 41.8 | 38.8 | 25.0 | 67.0 | 52.2 | 37.0 | 9.0 |
| 25 | 9.4 | 53.3 | 51.3 | 44.0 | 42.0 | 39.8 | 36.8 | 24.3 | 67.0 | 50.2 | 36.0 | 7.0 |
| 31.25 | 10.5 | 51.9 | 49.9 | 41.4 | 39.4 | 37.9 | 34.9 | 23.6 | 67.0 | 48.3 | 35.1 | 5.1 |
| 62.5 | 15.0 | 47.4 | 45.4 | 32.4 | 30.4 | 31.9 | 28.9 | 21.5 | 32.0 | |||
| 100 | 19.1 | 44.3 | 42.3 | 25.2 | 23.2 | 27.8 | 24.8 | 20.1 | 62.5 | 38.2 | 30.0 | |
| 200 | 27.6 | 39.8 | 37.8 | 12.2 | 10.2 | 21.8 | 18.8 | 18.0 | 27.0 | |||
| 250 | 31.1 | 38.3 | 36.3 | 7.3 | 5.3 | 19.8 | 16.8 | 17.3 | 56.5 | 30.2 | 26.0 | |
| 300 | 34.3 | 37.1 | 35.1 | 2.9 | 0.9 | 18.3 | 15.3 | 16.8 | 55.3 | 28.7 | 25.2 | |
| 350 | 37.2 | 36.1 | 34.1 | 16.9 | 13.9 | 16.3 | 54.3 | 27.3 | 24.6 | |||
| 400 | 40.1 | 35.3 | 33.3 | 15.8 | 12.8 | 15.9 | 53.5 | 26.2 | 24.0 | |||
| 450 | 42.7 | 34.5 | 32.5 | 14.7 | 11.7 | 15.5 | 52.7 | 25.1 | 23.5 | |||
| 500 | 45.3 | 33.8 | 31.8 | 13.8 | 10.8 | 15.2 | 52.0 | 24.2 | 23.0 |
Voltage
| UL Voltage Rating | 300 V (CMR), 600 V (AWM) |
|---|
Mechanical Characteristics
| Bend Radius Table Notes | Theses cable are rated for both indoor and outdoor applications. For outdoor installations, the continuous flexing bend radius must be applied for outdoor use. Outdoor installations are susceptible to frequent movement due to environmental factors. |
|---|---|
| Bulk Cable Weight | 87.5 lbs/1000ft (130 kg/km) |
Temperature
| UL Temperature | 75°C |
|---|---|
| Operating | -40°C To +75°C |
| Installation | -25C To +75°C |
| Storage | -40°C To +60°C |
Bend Radius
| Installation Min. | 2.6 in (66 mm) |
|---|---|
| Flexing Min. | 5.1 in (130 mm) |
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Oil Resistance |
|---|---|
| Flammability / Reaction to Fire | UL 1685 Flame only |
| CPR Compliance | CPR Euroclass: Fca |
| NEC / UL Compliance | Article 800, Article 725, PLTC - CMR/CMX Outdoor |
| AWM Compliance | AWM 21047 |
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
| NEMA Compliance | ANSI/NEMA WC-66 |
| Data Category | Category 6A |
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 6A |
| ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-5 |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical system. |
|---|
History
| Update and Revision | Revision Number: 0.34 Revision Date: 02-26-2026 |
|---|
Resources
Related category 6a cable

10GA22
CAT 6A 4P 23AWG, U/UTP, LSZH Jkt, Indoor
23 · BC - Bare Copper · PE - Polyethylene · LSZH - Low Smoke Zero Halogen (Flame Retardant)

10GA24
CAT 6A 4P 23AWG, U/UTP, LSZH Jkt, Indoor
23 · BC - Bare Copper · PE - Polyethylene · LSZH - Low Smoke Zero Halogen (Flame Retardant)

10GA25
10GA25 Cat 6A Cable, F/UTP, LSZH, 4 Pair, AWG 23, Indoor
23 · BC - Bare Copper · PE - Polyethylene · LSZH - Low Smoke Zero Halogen (Flame Retardant)

10GAB1
CAT 6A 23AWG, U/UTP, LSZH Jkt, GB 31247 B1 Rating, Indoor
23 · BC - Bare Copper · PE - Polyethylene · LSZH - Low Smoke Zero Halogen (Flame Retardant)