Belden Store
IEA005

Product Number: IEA005

DataTuff® 6A, High Flex, 4 Pr #26 Str TC, PO Ins, OS+TC Brd, TPE Jkt, CMR, CMX

Industrial Ethernet Cat 6A, 4 Pair 26AWG (Stranded 7X34) Tinned Copper, PO Insulation, X-Spline, Beldfoil Shield, TPE Outer Jacket, UL CMR, CMX Outdoor, OIL RES II, SUN RES, AWM 600V

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable ApplicationsHigh Flex, Automation, Robotics, exposure to oil and gasoline, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc.

Construction Details

Overall Cable Diameter (Nominal)0.29 in (7.4 mm)

Conductor

ElementPair(s)
Size26 AWG
Stranding7x34
MaterialTC - Tinned Copper
No. of Pairs4

Insulation

ElementPair(s)
MaterialPO - Polyolefin
Nom. Insulation Diameter0.034 in (0.86 mm)
Color CodeBlue & White/Blue, Orange & White/Orange, Green & White/Green, Brown & White/Brown

Outer Shield

Shield TypeMaterialCoverage
TapeBi-Laminate (Alum+Poly)100%
BraidTinned Copper (TC)75%

Outer Jacket

MaterialTPE - Thermoplastic Elastomer
Nom. Diameter0.29 in (7.4 mm)

Electrical Characteristics

Electricals

Max. Conductor DCR44.4 Ohm/1000ft (146 Ohm/km)

Delay

Max. Delay540 ns/100m
Max. Delay Skew45 ns/100m
Nom. Velocity of Prop.67%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted) [Ohm]Max./Min. Fitted Impedance [Ohm]Min. TCL [dB]Min. ELTCTL [dB]Max. Surface Transfer Impedance [mOhm/m]Min. Coupling Attenuation [dB]
13.1 dB/100m74.372.367.864.820.0100 ± 15100 +/- 1040.035.050.0
45.7 dB/100m65.363.355.852.823.0100 ± 15100 ± 1540.023.075.9
88.0 dB/100m60.858.849.746.724.5100 ± 15100 ± 1540.016.993.5
108.9 dB/100m59.357.347.844.825.0100 ± 15100 ± 1540.015.0100.0
1611.2 dB/100m56.254.243.740.725.0100 ± 15100 ± 1538.010.9135.3
2012.6 dB/100m54.852.841.838.825.0100 ± 15100 ± 1537.09.0155.8
2514.1 dB/100m53.351.339.836.824.2100 ± 15100 ± 1536.07.0179.5
31.2515.8 dB/100m51.949.97.934.923.3100 ± 15100 ± 1035.15.585
62.522.5 dB/100m47.445.431.928.920.7100 ± 15100 ± 103285
10028.7 dB/100m44.342.327.824.819.0100 ± 15100 ± 1030.085
20041.4 dB/100m39.837.821.818.819.0100 ± 15100 ± 1027.078.9
25046.6 dB/100m38.336.319.816.815.6100 ± 32100 ± 1026.077
30051.4 dB/100m37.135.118.315.314.9100 ± 32100 ± 1025.275.5
40060.1 dB/100m35.333.315.812.813.8100 ± 32100 ± 1024.072.9
50067.9 dB/100m33.831.813.810.813.0100 ± 32100 ± 1023.071.0

Voltage

UL Voltage Rating600 V (UL 2463)

Mechanical Characteristics

Table NotesFlex Life: 10 million cycles, C-track radius 15 times diameter. Torsion: 3 million cycles, +/- 270 degrees. Maximum installation length: 216 feet (66 meters).
Max. Pull Tension28 lbs (13 kg)
Bulk Cable Weight40 lbs/1000ft

Temperature

UL Temperature75°C
Operating-40°C To +75°C
Installation-20°C To +80°C
Storage-40°C To +80°C

Bend Radius

Stationary Min.2.9 in (74 mm)
Installation Min.2.9 in (74 mm)

Standards and Compliance

Environmental SuitabilityIndoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance
Flammability / Reaction to FireUL 1666 - Riser, VW-1
NEC / UL ComplianceArticle 800, CMX-Outdoor, CMR
AWM ComplianceAWM 2463
CEC / C(UL) ComplianceCMR-CMX OUTDOOR.
Data CategoryCategory 6A
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6A
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.269 Revision Date: 05-07-2026

Resources