DataTuff® 6A, High Flex, 4 Pr #24 Str TC, PO Ins, OS+TC Brd, TPE Jkt, CMR, CMX
Industrial Ethernet Cat 6A, 4 Pair 24AWG (Stranded 7X32) Tinned Copper, PO Insulation, X-Spline, Beldfoil Shield, TPE Outer Jacket, UL CMR, CMX Outdoor, OIL RES II, SUN RES, AWM 600V
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Suitable Applications | High Flex, Automation, Robotics, exposure to oil and gasoline, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 0.322 in (8.18 mm) |
|---|
Conductor
| Element | Pair(s) |
|---|---|
| Size | 24 AWG |
| Stranding | 7x32 |
| Material | TC - Tinned Copper |
| No. of Pairs | 4 |
Insulation
| Element | Pair(s) |
|---|---|
| Material | PO - Polyolefin |
| Nom. Insulation Diameter | 0.045 in (1.1 mm) |
| Color Code | Blue & White/Blue, Orange & White/Orange, Green & White/Green, Brown & White/Brown |
Outer Shield
| Shield Type | Material | Coverage |
|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% |
| Braid | Tinned Copper (TC) | 75% |
Outer Jacket
| Material | TPE - Thermoplastic Elastomer |
|---|---|
| Nom. Diameter | 0.322 in (8.18 mm) |
Electrical Characteristics
Electricals
| Max. Conductor DCR | 28.8 Ohm/1000ft (94.5 Ohm/km) |
|---|
Delay
| Max. Delay | 540 ns/100m |
|---|---|
| Max. Delay Skew | 45 ns/100m |
| Nom. Velocity of Prop. | 67% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) [Ohm] | Max./Min. Fitted Impedance [Ohm] | Min. TCL [dB] | Min. ELTCTL [dB] | Max. Surface Transfer Impedance [mOhm/m] | Min. Coupling Attenuation [dB] |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2.5 dB/100m | 74.3 dB | 72.3 dB | 67.8 | 64.8 | 20.0 | 100 ± 15 | 100 +/- 10 | 40.0 | 35.0 | 50.0 | |
| 4 | 4.6 dB/100m | 65.3 | 63.3 | 55.8 | 52.8 | 23.0 | 100 ± 15 | 100 ± 15 | 40.0 | 23.0 | 75.9 | |
| 8 | 6.4 dB/100m | 60.8 | 58.8 | 49.7 | 46.7 | 24.5 | 100 ± 15 | 100 ± 15 | 40.0 | 16.9 | 93.5 | |
| 10 | 7.1 dB/100m | 59.3 | 57.3 | 47.8 | 44.8 | 25.0 | 100 ± 15 | 100 ± 15 | 40.0 | 15.0 | 100.0 | |
| 16 | 9.0 dB/100m | 56.2 | 54.2 | 43.7 | 40.7 | 25.0 | 100 ± 15 | 100 ± 15 | 38.0 | 10.9 | 135.3 | |
| 20 | 10.1 dB/100m | 54.8 | 52.8 | 41.8 | 38.8 | 25.0 | 100 ± 15 | 100 ± 15 | 37.0 | 9.0 | 155.8 | |
| 25 | 11.3 dB/100m | 53.3 | 51.3 | 39.8 | 36.8 | 24.2 | 100 ± 15 | 100 ± 15 | 36.0 | 7.0 | 179.5 | |
| 31.25 | 12.6 dB/100m | 51.9 | 49.9 | 7.9 | 34.9 | 23.3 | 100 ± 15 | 100 ± 10 | 35.1 | 5.5 | 85 | |
| 62.5 | 18.0 dB/100m | 47.4 | 45.4 | 31.9 | 28.9 | 20.7 | 100 ± 15 | 100 ± 10 | 32 | 85 | ||
| 100 | 23.0 dB/100m | 44.3 | 42.3 | 27.8 | 24.8 | 19.0 | 100 ± 15 | 100 ± 10 | 30.0 | 85 | ||
| 200 | 33.1 dB/100 | 39.8 | 37.8 | 21.8 | 18.8 | 19.0 | 100 ± 15 | 100 ± 10 | 27.0 | 78.9 | ||
| 250 | 37.3 dB/100m | 38.3 | 36.3 | 19.8 | 16.8 | 15.6 | 100 ± 32 | 100 ± 10 | 26.0 | 77 | ||
| 300 | 41.1 dB/100m | 37.1 | 35.1 | 18.3 | 15.3 | 14.9 | 100 ± 32 | 100 ± 10 | 25.2 | 75.5 | ||
| 400 | 48.1 dB/100m | 35.3 | 33.3 | 15.8 | 12.8 | 13.8 | 100 ± 32 | 100 ± 10 | 24.0 | 72.9 | ||
| 500 | 54.3 dB/100m | 33.8 | 31.8 | 13.8 | 10.8 | 13.0 | 100 ± 32 | 100 ± 10 | 23.0 | 71.0 |
Voltage
| UL Voltage Rating | 600 V (UL 2463) |
|---|
Mechanical Characteristics
| Table Notes | Flex Life: 10 million cycles, C-track radius 15 times diameter. Torsion: 3 million cycles, +/- 270 degrees. Maximum installation length: 272 feet (83 meters). |
|---|---|
| Max. Pull Tension | 44 lbs (20 kg) |
| Bulk Cable Weight | 48 lbs/1000ft |
Temperature
| UL Temperature | 75°C |
|---|---|
| Operating | -40°C To +75°C |
| Installation | -20°C To +80°C |
| Storage | -40°C To +80°C |
Bend Radius
| Stationary Min. | 2.58 in (65.5 mm) |
|---|---|
| Installation Min. | 2.58 in (65.5 mm) |
| Flexing Min. | 2.58 in (65.5 mm) |
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance |
|---|---|
| Flammability / Reaction to Fire | UL 1666 - Riser, VW-1 |
| NEC / UL Compliance | Article 800, CMX-Outdoor, CMR |
| AWM Compliance | AWM 2463 |
| CEC / C(UL) Compliance | CMR-CMX OUTDOOR. |
| Data Category | Category 6A |
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 6A |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
| Update and Revision | Revision Number: 0.279 Revision Date: 05-07-2026 |
|---|
Resources
Related category 6a cable

10GA22
CAT 6A 4P 23AWG, U/UTP, LSZH Jkt, Indoor
23 · BC - Bare Copper · PE - Polyethylene · LSZH - Low Smoke Zero Halogen (Flame Retardant)

10GA24
CAT 6A 4P 23AWG, U/UTP, LSZH Jkt, Indoor
23 · BC - Bare Copper · PE - Polyethylene · LSZH - Low Smoke Zero Halogen (Flame Retardant)

10GA25
10GA25 Cat 6A Cable, F/UTP, LSZH, 4 Pair, AWG 23, Indoor
23 · BC - Bare Copper · PE - Polyethylene · LSZH - Low Smoke Zero Halogen (Flame Retardant)

10GAB1
CAT 6A 23AWG, U/UTP, LSZH Jkt, GB 31247 B1 Rating, Indoor
23 · BC - Bare Copper · PE - Polyethylene · LSZH - Low Smoke Zero Halogen (Flame Retardant)