Belden Store
DOSP6AU

Product Number: DOSP6AU

Category 6A OSP Cable, 4 Pair, U/UTP, Gel Free

Category 6A Premise Horizontal Cable, OSP Rated, 4 Pair, 23 AWG Solid Bare Copper Conductors, U/UTP, Gel Free

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

DOSP6AU is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
DOSP6AU 0101000BlackReel1,000 ftOrder online

Specifications

Product Overview

Suitable ApplicationsOSP-Outside Plant, Premise Horizontal Cable, Ethernet up to 10GBASE-T, Wi-Fi 6, Wi-Fi 5, PoE++, PoE+, PoE, Noisy Enivronments, HDBaseT, IP Cameras
PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .

Construction Details

Overall Cable Diameter (Nominal)0.29 in (7.4 mm)

Conductor

Size23
StrandingSolid
MaterialBC - Bare Copper
No. of Pairs4

Insulation

MaterialPO - Polyolefin
Color CodeWhite & Blue, White & Orange, White & Green, White & Brown

Outer Jacket

SeparatorCenter Member (Patented T-Spline®), EquiBlockTM Barrier Technology
MaterialPO - Polyolefin
Nom. Diameter0.29 in (7.4 mm)
RipcordYes

Electrical Characteristics

Electricals

Max. Conductor DCR82 Ohm/km (25 Ohm/1000ft)
Max. Capacitance Unbalance45 pF/100m

Delay

Frequency100 MHz
Max. Delay537.6 ns/100m
Max. Delay Skew45 ns/100m
Nom. Velocity of Prop.68%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation) [dB/100m]Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted)Max./Min. Fitted ImpedanceMin. PSANEXT [dB]Min. PSAACRF [dB]Min. TCL [dB]Min. ELTCTL [dB]
12.174.372.372.270.267.864.820.0105 +/- 10115 +/- 1567.067.040.035.0
43.865.363.361.559.555.852.823.0105 +/- 10100 +/- 767.066.240.023.0
85.360.858.855.453.449.746.724.5100 +/- 22100 +/- 767.060.140.016.9
105.959.357.353.451.447.844.825.0100 +/- 22100 +/- 767.058.240.015.0
167.556.254.248.846.843.740.725.0100 +/- 22100 +/- 767.054.138.010.9
208.454.852.846.444.441.838.825.0100 +/- 22100 +/- 767.052.237.09.0
259.453.351.344.042.039.836.824.3100 +/- 22100 +/- 767.050.236.07.0
31.2510.551.949.941.439.437.934.923.6100 +/- 22100 +/- 767.048.335.15.1
62.515.047.445.432.430.431.928.921.5100 +/- 22100 +/- 765.642.332.0
10019.144.342.325.223.227.824.820.1100 +/- 22100 +/- 762.538.230.0
20027.639.837.812.210.221.818.818.0100 +/- 22100 +/- 758.032.227.0
25031.138.336.37.35.319.816.817.3100 +/- 32100 +/- 756.530.226.0
30034.337.135.12.90.918.315.316.8100 +/- 32100 +/- 755.328.725.2
35037.236.134.116.913.916.3100 +/- 32100 +/- 754.327.324.6
40040.135.333.315.812.815.9100 +/- 32100 +/- 753.526.224.0
45042.734.532.514.711.715.5100 +/- 32100 +/- 752.725.123.5
50045.333.831.813.810.815.2100 +/- 32100 +/- 752.024.223.0

Voltage

Voltage Rating300 V

Mechanical Characteristics

Max. Pull Tension25 lbs (11 kg)
Bulk Cable Weight33 lbs/1000ft (49 kg/km)

Temperature

Operating-20°C To +70°C
Installation0°C To +60°C
Storage-40°C To +75°C

Bend Radius

Installation Min.2.9 in (74 mm)

Standards and Compliance

Environmental SuitabilityOutdoor - Water Exposure, Outdoor
IEEE ComplianceIEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Data CategoryCategory 6A
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6A
ISO/IEC Compliance11801 ed 2.2 (2011) Class EA
CENELEC ComplianceSegregation class according EN50174-2 = a

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Suitable for burial or use in outdoor wet locations. Not recommended for Direct Burial applications without additional crush and impact protection. Additional crush and impact protection would include cable armoring, installation in conduit or installation with over top barriers per Belden Technical Bulletin T/8-6. Cable jacket system is specially designed to protect cable core. Cable contains no water-blocking tapes, gels, or powders. Install in accordance with all applicable electrical codes. Maintain jacket integrity throughout installation process. Do not allow water or fluids to penetrate jacket sheath or to enter ends of cable. Ensure ends of cable will be protected from water/fluids after installation. Belden recommends using an entrance demarcation point when transitioning inside buildings with OSP cables. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1.