Belden Store
50106AFLS

Product Number: 50106AFLS

BELDEN Industrial Ethernet CAT6A cable, F/UTP LSZH SWA LSZH, Outdoor

BELDEN Industrial Ethernet CAT6A,F/UTP, 4x2x23AWG, Solid Bare Copper Conductors,HDPE Insulation, PET+Al-Mylar (Aluminium facing outside)shield, LSZH Jacket,UV Resistance cable

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

50106AFLS is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorLengthOrder
50106AFLS 010305MBlack305 mOrder online
50106AFLS 009305MWhite305 mOrder online

Specifications

Product Overview

Suitable ApplicationsIndustrial Ethernet cables are used for interconnecting Industrial Ethernet Switches, IP controllers, media convertors, distributed control system, programmable logic controller and transmitting industrial protocol data signals. These are Cat 6A highly durable & ruggedized cables for outdoor use meeting ISO/IEC 11801 ed. 2.0 , IEC61156-5 CAT6A , IEC 60332-1-2, IEC60332-3-22

Construction Details

Overall Cable Diameter (Nominal)12.50 mm (0.4921 in)

Conductor

ElementPair(s)
Size23 AWG
MaterialBC - Bare Copper
No. of Pairs4

Insulation

MaterialPE - Polyethylene
Nom. Insulation Diameter1.14 mm (0.0449 in)
Color Code1. Blue & Blue / White, 2. Orange & Orange / White, 3. Green & Green / White, 4. Brown & Brown / White

Inner Shield

ElementOverall
Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Drainwire Type26 AWG (Solid) TC

Inner Jacket

MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Nom. Diameter9.1 mm (0.36 in)

Armor

Armor Type & MaterialSWA - Steel Wire Armor
Armor Material Diameter0.8 mm (0.031 in)

Outer Jacket

MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Nom. Diameter12.5 mm (0.492 in)

Electrical Characteristics

Transfer Impedance ClassGrade 2

Electricals

Max. Conductor DCR95@20°C( Ohm/km)
Max. Mutual Capacitance56 pF/m (17 pF/ft)
Max. Capacitance Unbalance1,600 pF/km

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation) [dB/100m]Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Min. TCL [dB]Min. ELTCTL [dB]
12.175.372.373.270.268.06520.040.035.0
43.866.363.362.559.556.05323.034.023.0
105.960.357.354.451.448.04525.030.015.0
167.557.254.249.746.743.940.925.028.010.9
31.310.552.949.942.439.438.135.123.625.15.1
62.515.048.445.433.430.432.129.121.522.0
10019.145.342.326.223.2282520.120.0
12521.543.840.822.319.326.123.119.419.0
20027.640.837.813.210.2221918.017.0
25031.139.336.38.25.22017.017.316.0
35037.337.134.117.114.117.316
50045.334.831.814.011.017.3

Voltage

UL Voltage Rating72 V DC

Mechanical Characteristics

Temperature

UL Temperature-30°C To +60°C

Standards and Compliance

Environmental SuitabilityOutdoor, Sunlight Resistance, UV Resistance
Flammability / Reaction to FireIEC 60332-1-2, IEC 60332-3-22
ISO/IEC ComplianceIEC 61156-5
European Halogen Free StandardsIEC 60754-1 - Halogen Amount = 5 mg/g, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3

History

Update and RevisionRevision Number: 0.34 Revision Date: 05-07-2026

Resources

Related category 6a cable