Belden Store
2147A

Product Number: 2147A

Category 6A Indoor/Outdoor Cable, 4 Pair, U/UTP, OSP/CM-ST1, LSZH

Category 6A Premise Horizontal Cable (500 MHz), Indoor/Outdoor OSP/CM-ST1, 4 Pair, 23 AWG Solid Bare Copper Conductors, U/UTP, Haloarrest® LSZH Inner Jacket, Gel-Filled, UV Resistant Flame Retardant Haloarrest® LSZH Outer Jacket

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

2147A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorUPCOrder
2147A 0101000Black612825379485Order online

Specifications

Product Overview

Suitable ApplicationsOSP-Outdoor, Indoor/Outdoor, Premise Horizontal Cable, Ethernet up to 10GBASE-T, Wi-Fi 6, Wi-Fi 5, PoE++, PoE+, PoE, HDBaseT
PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .

Construction Details

WaterblockingGel Filled
Overall Cable Diameter (Nominal)0.370 in (9.40 mm)

Conductor

Size23 AWG
StrandingSolid
MaterialBC - Bare Copper
No. of Pairs4

Insulation

MaterialPO - Polyolefin
Color CodeWhite & Blue, White & Orange, White & Green, White & Brown

Inner Jacket

MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Nom. Diameter0.270 in (6.86 mm)
RipcordYes
ColorBlack

Outer Jacket

SeparatorCenter Member (Patented X-Spline®), EquiBlockTM Barrier Technology
MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Material Trade NameHaloarrest®
Nom. Diameter0.370 in (9.40 mm)
RipcordYes

Electrical Characteristics

Electricals

Max. Conductor DCR82 Ohm/km (25 Ohm/1000ft)
Max. Capacitance Unbalance45 pF/100m

Delay

Frequency100 MHz
Max. Delay537.6 ns/100m
Max. Delay Skew45 ns/100m
Nom. Velocity of Prop.64%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation) [dB/100m]Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted) [Ohm]Max./Min. Fitted Impedance [Ohm]Min. PSANEXT [dB]Min. PSAACRF [dB]Min. TCL [dB]Min. ELTCTL [dB]
12.174.372.372.270.267.864.820.0100 +/- 5115 +/- 1567.067.040.035.0
43.865.363.361.559.555.852.823.0100 +/- 5100 +/- 767.066.240.023.0
85.360.858.855.453.449.746.724.5100+/- 22100 +/- 767.060.140.016.9
105.959.357.353.451.447.844.825.0100+/- 22100 +/- 767.058.240.015.0
167.556.254.248.846.843.740.725.0100+/- 22100 +/- 767.054.138.010.9
208.454.852.846.444.441.838.825.0100+/- 22100 +/- 767.052.237.09.0
259.453.351.344.042.039.836.824.3100+/- 22100 +/- 767.050.236.07.0
31.2510.551.949.941.439.437.934.923.6100+/- 22100 +/- 767.048.335.15.1
62.515.047.445.432.430.431.928.921.5100+/- 22100 +/- 765.642.332.0
10019.144.342.325.223.227.824.820.1100+/- 22100 +/- 762.538.230.0
20027.639.837.812.210.221.818.818.0100+/- 22100 +/- 758.032.227.0
25031.138.336.37.35.319.816.817.3100 +/- 32100 +/- 756.530.226.0
30034.337.135.12.90.918.315.316.8100 +/- 32100 +/- 755.328.725.2
35037.236.134.116.913.916.3100 +/- 32100 +/- 754.327.324.6
40040.135.333.315.812.815.9100 +/- 32100 +/- 753.526.224.0
45042.734.532.514.711.715.5100 +/- 32100 +/- 752.725.123.5
50045.333.831.813.810.815.2100 +/- 32100 +/- 752.024.223.0

Voltage

UL Voltage Rating300 V (CM-LS)

Mechanical Characteristics

Max. Pull Tension25 lbs (11 kg)
Bulk Cable Weight67 lbs/1000ft (100 kg/km)

Temperature

UL Temperature75°C
Operating-40°C To +75°C
Installation-20°C To +75°C
Storage-40°C To +75°C

Bend Radius

Stationary Min.3.0 in (76 mm)
Installation Min.3.75 in (95.3 mm)

Standards and Compliance

Environmental SuitabilityIndoor/Outdoor, Indoor, Outdoor, Non-Halogenated, Sunlight Resistance, Aerial - When supported by messenger wire
Flammability / Reaction to FireUL 1685 (UL Loading-Limited Smoke)
NEC / UL ComplianceArticle 800, CM-ST1
CEC / C(UL) ComplianceCM-ST1.
ICEA ComplianceS-116-732, S-56-434, S-99-689, S-100-685
IEEE ComplianceIEEE 802.3bt Type 1, Type 2, Type 3, Type 4
NEMA ComplianceANSI/NEMA WC-66
Data CategoryCategory 6A
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6A
ISO/IEC ComplianceISO/IEC 11801-1, IEC 61156-5
CENELEC ComplianceSegregation class according EN50174-2 = a
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Fully Water Blocked. Suitable for burial or use in Buildings in Wet Locations. Not recommended for Direct Burial applications without additional crush and impact protection.

History

Update and RevisionRevision Number: 0.466 Revision Date: 07-27-2026

Resources

Related category 6a cable