Belden Store
10GXE00P

Product Number: 10GXE00P

10GX Category 6A Enhanced Cable, 4 Pair, F/UTP, Black PE Outdoor, UV

Category 6A Premise Horizontal Cable (625MHz), 4-Pair, 23 AWG Solid Bare Copper Conductors, F/UTP, Polyethylene Insulation, Beldfoil® shield, AWG 26 solid tinned copper drainwire, Black PE Jacket, UV resistant

Availability
EMEA
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable ApplicationsHorizontal and building backbone cable; Support current and future Category 6A and 6 applications, such as: 10GBase-T (10 Gigabit Ethernet), 1000Base-T (Gigabit Ethernet), 100 Base-T, 10 Base-T, FDDI, ATM
PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .

Construction Details

Outer Shield Table NotesAluminum facing outside
Overall Cable Diameter (Nominal)7.6 mm (0.30 in)

Conductor

ElementIndividual Pair
Size23 AWG
StrandingSolid
MaterialBC - Bare Copper
No. of Pairs4

Insulation

ElementIndividual Pair
MaterialPE - Polyethylene
Nom. Insulation Diameter1.18 mm (0.0465 in)
Color CodeWhite/Blue & Blue, White/Orange & Orange, White/Green & Green, White/Brown & Brown

Cable Core

Description4 pairs twisted to cable core covered with a polyester foil
SeparatorCenter Member (Patented X-Spline®)

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type26 AWG (Solid) TC

Outer Jacket

MaterialPE - Polyethylene
Nom. Diameter7.6 mm (0.30 in)
RipcordYes

Electrical Characteristics

High Frequency Table NotesLimits below 4 MHz are for information only. Reference standard: IEC 61156-5
Transfer Impedance ClassGrade 2
Screening ClassType II
Screening Table NotesCoupling Attenuation

Electricals

Max. Conductor DCR95 Ohm/km (29 Ohm/1000ft)
Max. Mutual Capacitance56 pF/m (17 pF/ft)
Max. Capacitance Unbalance160 pF/100m
Nom. Characteristic Impedance100 Ohm

Delay

Max. Delay Skew45 ns/100m
Nom. Velocity of Prop.67%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation) [dB/100m]Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Min. PSANEXT [dB]Min. PSAACRF [dB]Min. TCL [dB]Min. ELTCTL [dB]
12.175.372.373.270.268652067674035
43.866.363.362.559.55653236766.23423
105.960.357.354.451.44845256758.23015
167.557.254.249.846.843.940.9256754.12810.9
31.210.552.949.942.439.438.135.123.66748.325.15.1
62.51548.445.433.430.432.129.121.565.642.322
10019.145.342.326.223.2282520.162.538.220
12521.543.840.822.319.326.123.119.46136.319
20027.640.837.813.210.22219185832.217
25031.139.336.38.35.3201717.356.530.216
30034.338.135.13.90.918.515.517.355.328.7
50045.334.831.8-10.4-13.4141117.35224.2
62551.233.430.4-17.8-20.812.19.117.350.622.3

Transfer Impedance

FrequencyMax. Transfer Impedance
1 MhzMax. 50 mOhm/m
10 MhzMax. 100 mOhm/m
30 MhzMax. 200 mOhm/m
100 MhzMax. 1000 mOhm/m

Voltage

Voltage Rating72 V DC

Mechanical Characteristics

Max. Pull Tension110 N (25 lbf)
Bulk Cable Weight50 kg/km (34 lbs/1000ft)

Temperature

Operating-30°C to +60°C
Installation0°C To +50°C

Bend Radius

Stationary Min.29 mm (1.1 in)
Installation Min.58 mm (2.3 in)

Standards and Compliance

Environmental SuitabilityOutdoor, Sunlight Resistance - Black only
IEEE CompliancePoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Data CategoryCategory 6A
TIA/EIA ComplianceANSI/TIA 568.2-D
ISO/IEC ComplianceISO/IEC 11801-1
CENELEC ComplianceEN 50173-1, Segregation class according EN50174-2 = c
European Halogen Free StandardsIEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3, IEC 61034-2 - Smoke Density Min. Transmittance = 60%
European Directive ComplianceEU CE Mark
UK Regulation ComplianceUKCA Mark

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system.

History

Update and RevisionRevision Number: 0.8 Revision Date: 03-23-2026

Resources

Related category 6a cable