Belden Store
7962A

Product Number: 7962A

DataTuff® Cat 5e, Quad (2 Pr) #22 Str TC, PO Ins, OS+TC Brd, TPE Jkt, CM CMX-Outdoor

Industrial Ethernet Cat 5e, Quad (2 Pair) 22AWG (19x34) Tinned Copper, PO Insulation, Overall Beldfoil®+Tinned Copper Braid(85%) Shield, TPE Outer Jacket, CM CMX-Outdoor

Availability
Global
Status
Active
Orderable items
4

Ships from and sold by A5 IT.

Part numbers

7962A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPC/EANOrder
7962A.00305GreenReel305 m8719605016812Order online
7962A.00610GreenReel610 m8719605016829Order online
7962A 1SW1000Green, RAL 6018——612825367024Order online
7962A 1SW2000Green, RAL 6018——612825367031Order online

Specifications

Product Overview

Suitable ApplicationsPROFINET, outdoor, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc.

Construction Details

Overall Cable Diameter (Nominal)0.276 in (7.01 mm)

Conductor

ElementQuad(s)
Size22 AWG
Stranding19x34
MaterialTC - Tinned Copper

Insulation

MaterialPO - Polyolefin
Color CodeWhite, Blue, Yellow, Orange

Inner Jacket

MaterialPE - Polyethylene
Nom. Diameter0.169 in (4.29 mm)

Outer Shield

Shield TypeMaterialCoverage
TapeBi-Laminate (Alum+Poly)100%
BraidTinned Copper (TC)85%

Outer Jacket

MaterialTPE - Thermoplastic Elastomer
Nom. Diameter0.276 in (7.01 mm)
RipcordNo

Electrical Characteristics

Electricals

Max. Conductor DCR57 Ohm/km (17 Ohm/1000ft)
Max. Capacitance Unbalance150 pF/ft

Delay

Max. Delay552 ns/100m
Nom. Velocity of Prop.70%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation) [dB/100m]Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted) [Ohm]Max./Min. Fitted Impedance [Ohm]
12.665.362.363.263.860.823100 ± 20.2105 ±10
44.856.353.356.351.748.723100 ± 14.2100 ±10
86.851.848.846.245.742.723100 ± 11.3100 ±10
107.650.347.343.943.840.825100 ± 11.3100 ±10
169.747.344.335.239.736.725100 ± 11.3100 ±10
2010.845.842.836.537.734.725100 ± 11.3100 ±10
2512.244.341.334.235.832.825.5100 ± 11.3100 ±10
31.2513.742.939.931.333.930.923.6100 ± 13.2100 ±10
62.519.838.435.421.627.824.821.5100 ± 16.9100 ±10
10025.635.332.317.123.820.820.1100 ± 20.0100 ±10

Voltage

UL Voltage Rating300 V (CM, CMX-Outdoor), 600 V (AWM 20626)

Mechanical Characteristics

Table NotesFlex Life: C-Track 1 million cycles on 3-inch radius.
Max. Pull Tension55 lbs (25 kg)
Bulk Cable Weight45 lbs/1000ft (67 kg/km)

Temperature

UL Temperature75°C
Operating-40°C To +80°C
Installation-20°C To +60°C
Storage-40°C To +80°C

Bend Radius

Stationary Min.2.560 in (65.02 mm)

Standards and Compliance

Environmental SuitabilityIndoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Oil Resistance
Flammability / Reaction to FireUL 1685 (UL Loading), FT4, IEEE 1202 Vertical Tray Flame Test
NEC / UL ComplianceArticle 800, CM, CMX-Outdoor, ITC, PLTC
AWM ComplianceAWM 20626
CEC / C(UL) ComplianceCMX-Outdoor.
NEMA ComplianceNEMA WC-63.1
Data CategoryCategory 5e
TIA/EIA ComplianceANSI/TIA-568.2-D Category 5e
ISO/IEC ComplianceISO/IEC 11801-1, IEC 61156-6
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesOperating Temperature subject to length de-rating. Cable passes -40C Cold Bend per UL 1581. Limits below 4 MHz are for information only.

History

Update and RevisionRevision Number: 0.582 Revision Date: 06-11-2026

Resources

Related category 5e cable