Belden Store
127929A

Product Number: 127929A

DataTuff® 5e, 4 Bonded-Pr #24 Sol BC, PO Ins, OS, PVC Jkt, AIA Armor, PVC Jkt, CMG CM -40C

Industrial Ethernet Cat 5e, 4 Bonded-Pair 24AWG (Solid) Bare Copper, PO Insulation, Overall Beldfoil® Shield, PVC Inner Jacket, Aluminum Interlock Armor, PVC Outer Jacket, CMG CM -40C

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable Applicationsmining, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. exposure to rodent, crush, or cut through force,

Physical Characteristics (Overall)

Conductor Count8
Total Number of Pairs4
Bonded-Pair ConstructionYes

Conductor

ElementPair(s)
AWG24
StrandingSolid
MaterialBC - Bare Copper
No. of Pairs4

Insulation

ElementPair(s)
MaterialPO - Polyolefin
Nominal Diameter0.044 in

Color Chart

Color
White/Blue Stripe & Blue
White/Orange Stripe & Orange
White/Green Stripe & Green
White/Brown Stripe & Brown

Inner Jacket

MaterialPVC - Polyvinyl Chloride
Nominal Diameter0.275 in

Outer Shield

TypeTape
MaterialBi-Laminate (Alum+Poly)
Material Trade NameBeldfoil®
Coverage [%]100%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nominal Diameter0.583 in
Separator MaterialPolyester Tape

Construction and Dimensions

Armor

Diameter over Armoring0.495 in

Electrical Characteristics

Conductor DCR

Max. Conductor DCR93.8 Ohm/km

Capacitance

Max. Capacitance Unbalance330 pF/100m

Delay

Max. Delay538 ns/100m
Max. Delay Skew45 ns/100m
Nominal Velocity of Propagation (VP) [%]70%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Min. SRL (Structural Return Loss)Max./Min. Input Impedance (unFitted)Max./Min. Fitted Impedance
1 MHz2.0 dB/100m65.3 dB62.3 dB63 dB60 dB63.8 dB60.8 dB20 dB23 dB100 ± 15 Ohm100 ± 15 Ohm
4 MHz4.1 dB/100m56.3 dB53.3 dB51 dB49 dB51.7 dB48.7 dB23 dB23 dB100 ± 15 Ohm100 ± 15 Ohm
8 MHz5.8 dB/100m51.8 dB48.8 dB46 dB43 dB45.7 dB42.7 dB24.5 dB24.5 dB100 ± 15 Ohm100 ± 15 Ohm
10 MHz6.5 dB/100m50.3 dB47.3 dB43 dB41 dB43.8 dB40.8 dB25 dB25 dB100 ± 15 Ohm100 ± 15 Ohm
16 MHz8.2 dB/100m47.3 dB44.3 dB39 dB36 dB39.7 dB36.7 dB25 dB25 dB100 ± 15 Ohm100 ± 15 Ohm
20 MHz9.3 dB/100m45.8 dB42.8 dB36.5 dB33.5 dB37.7 dB34.7 dB25 dB25 dB100 ± 15 Ohm100 ± 15 Ohm
25 MHz10.4 dB/100m44.3 dB41.3 dB33.9 dB30.9 dB35.8 dB32.8 dB24.3 dB24.3 dB100 ± 15 Ohm100 ± 15 Ohm
31.25 MHz11.7 dB/100m42.9 dB39.9 dB31 dB28 dB33.9 dB30.9 dB23.6 dB23.6 dB100 ± 15 Ohm100 ± 15 Ohm
62.5 MHz17.0 dB/100m38.4 dB35.4 dB22 dB19 dB27.8 dB24.8 dB21.5 dB21.5 dB100 ± 15 Ohm100 ± 15 Ohm
100 MHz22.0 dB/100m35.3 dB32.3 dB14 dB11 dB23.8 dB20.8 dB20.1 dB20.1 dB100 ± 15 Ohm

Voltage

UL DescriptionCM
UL Voltage Rating300 V

Temperature Range

UL Temperature Rating75°C
Storage Temperature Range-40°C To +85°C
Operating Temperature Range-40°C To +75°C

Mechanical Characteristics

UV ResistanceYes
Bulk Cable Weight134 lbs/1000ft
Maximum Recommended Pulling Tension100 lbs

Standards

NEC ArticlesArticle 800
NEC/(UL) ComplianceCM
CEC/C(UL) ComplianceCMG, HL
ISO/IEC ComplianceISO/IEC 1801 Cat 5e
CPR EuroclassEca
Data CategoryCategory 5e
TIA/EIA ComplianceANSI/TIA-568.2-D Category 5e

Applicable Environmental and Other Programs

Environmental SpaceIndoor/Outdoor

Suitability

Suitability - IndoorYes
Suitability - Oil ResistanceYes
Suitability - OutdoorYes
Suitability - Sunlight ResistanceYes

Flammability, LS0H, Toxicity Testing

CSA/C(UL) FlammabilityFT4
UL FlammabilityUL 1685 UL Loading
UL voltage rating300 V RMS

Product Notes

NotesOperating temperatures are subject to length de-rating

History

Update and RevisionRevision Number: 0.319 Revision Date: 02-20-2026

Resources

Related category 5e cable