Belden Store
7896Z

Product Number: 7896Z

DeviceBus®, 2 Pr #16+18 Str TC, XLPe+PP Ins, IS+OA TC Brd, LSZH-TS Jkt, 600V TC-ER-ST1

DeviceBus® for ODVA DeviceNetTM, 2 Pair 16+18AWG (19x29+19x30) Tinned Copper, XLPE+ PP Insulation, Individual Beldfoil® & OA Tinned Copper Braid(65%) Shield, LSZH Thermoset Outer Jacket, 600V TC-ER-ST1

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

7896Z is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorUPCFootnoteOrder
7896Z 0105000Black612825190868COrder online

Specifications

Product Overview

Suitable Applicationsharsh environment, ODVA device-level communication, used with CIP (common Industrial Protocol) for control, configuration, and data collection between devices, such as sensors and actuators, and higher level devices such as PLC, and PC in industrial automation, bus topology, etc.

Construction Details

Overall Cable Diameter (Nominal)0.646 in (16.4 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Power Pair(s)116 AWG19x29TC - Tinned Copper
Data Pair(s)118 AWG19x30TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessColor CodeNotes
Power Pair(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.031 in (0.79 mm)Red & Black
Data Pair(s)PP - Polypropylene0.068 in (1.7 mm)Blue & WhiteFlame Retardant

Inner Shield

ElementShield TypeMaterialCoverage
Power Pair(s)TapeBi-Laminate (Alum+Poly)100%
Data Pair(s)TapeBi-Laminate (Alum+Poly)100%

Outer Shield

Shield TypeBraid
MaterialTinned Copper (TC)
Coverage65%
Drainwire Type16 AWG (19x29) TC

Outer Jacket

MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant, Thermoset)
Nom. Thickness0.115 in (2.92 mm)
Nom. Diameter0.646 in (16.4 mm)

Electrical Characteristics

Nom Outer Shield DCR1.8 Ohm/1000ft (5.9 Ohm/km)

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Characteristic ImpedenceNom. DelayNom. Velocity of Prop.Max. Current
Power Pair(s)4.9 Ohm/1000ft (16 Ohm/km)8 Amps per Conductor at 25oC
Data Pair(s)6.9 Ohm/1000ft (23 Ohm/km)14.7 pF/ft (48.2 pF/m)120 Ohm1.6 ns/ft75%

Voltage

UL Voltage Rating600 V (TC-ER-ST1)

Mechanical Characteristics

Max. Pull Tension190 lbs (86 kg)
Bulk Cable Weight222 lbs/1000ft (330 kg/km)

Temperature

UL Temperature75°C Dry
Operating-20°C to +75°C
Installation-20°C To +75°C

Bend Radius

Stationary Min.6.0 in (150 mm)
Installation Min.6.0 in

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
Flammability / Reaction to FireUL 1685 UL Loading, 1202, IEC 60332-3-22
NEC / UL ComplianceArticle 336, TC-ER-ST1
AWM ComplianceI/II A/B
Marine ComplianceABS Type Approval 20-HS1959654-PDA
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)ODVA Cable V

Product Notes

NotesMeter marks on jacket to aid users in installation. ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark.

History

Update and RevisionRevision Number: 0.378 Revision Date: 02-20-2026
FootnoteC - CRATE REEL PUT-UP.

Resources

Related multi-pair cable