Belden Store
1340A

Product Number: 1340A

Fieldbus, 8 Pr #18 Str TC, PO Ins, IS/OS, PVC Jkt, 600V TC-ER

Fieldbus, 8 Pair 18AWG (7x26) Tinned Copper, PO Insulation, Individual & Overall Beldfoil® Shield, Orange PVC Outer Jacket, 600V TC-ER

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

1340A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
1340A 0035000OrangeReel5,000 ft612825112297COrder online

Specifications

Product Overview

Suitable Applicationsharsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Construction Details

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Pair(s)8187x26TC - Tinned Copper
Ground Wire187x26TC - Tinned Copper

Insulation

ElementMaterialColor Code
PVC - Polyvinyl ChlorideBlue, Orange and Numbered
Ground WirePVC - Polyvinyl ChlorideGreen/Yellow

Inner Shield

Shield TypeMaterialCoverage
TapeBi-Laminate (Alum+Poly)100%
Tinned Copper (TC)

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Diameter0.81 in

Electrical Characteristics

Electricals

Nom. Conductor DCR5.86 Ohm/1000ft (19.2 Ohm/km)
Nom. Capacitance Cond-to-Other (Conds + Shield)45 pF/ft (150 pF/m)
Max. Capacitance Unbalance1.2 pF/ft
Nom. Characteristic Impedence100 Ohm
Nom. Inductance0.22 μH/ft (0.72 μH/m)
Max. Current5.2 Amps per Conductor

High Frequency (Nominal/Typical)

Nom. Insertion Loss (Attenuation) [dB/100ft]0.08

Voltage

UL Voltage Rating600 V RMS

Mechanical Characteristics

Max. Pull Tension381 lbs (173 kg)

Temperature

UL Temperature75°C
Operating-30°C to +75°C

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance, Oil Resistance
Flammability / Reaction to FireUL1685 UL Loading
NEC / UL ComplianceArticle 336, TC-ER
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)

History

Update and RevisionRevision Number: 0.292 Revision Date: 09-07-2025
FootnoteC - CRATE REEL PUT-UP.

Resources

Related multi-pair cable