Belden Store
9250

Product Number: 9250

95Ω Twinax RG-22B/U Type, 1Pr #18 Str BC, PE Ins, PE Inner Jkt, Two TC Braids, Non-contaminating PVC Jkt

Twinax 95Ω RG-22B/U Type, 1 Pair, 18 AWG (7x26) bare copper, polyethylene insulation, polyethylene inner jacket, tinned copper double braid shield (95% coverage each), non-contaminating PVC jacket

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

9250 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
9250 010500BlackReel500 ft612825225751COrder online
9250 0101000BlackReel1,000 ft612825225744COrder online

Specifications

Product Overview

Suitable ApplicationsComputer, Instrumentation

Construction Details

RG Type22
Overall Cable Diameter (Nominal)0.416 in (10.6 mm)

Conductor

SizeStrandingNom. DiameterMaterialNotes
18 AWG7x260.046 inBC - Bare Copper
18 AWG7x260.046 inBC+TC - Bare Copper + Tinned CopperOnly center strand is Tinned

Insulation

MaterialNom. Insulation DiameterColor CodeNotes
PE - Polyethylene0.089 in (2.3 mm)ClearPE on both conductors
PE - Polyethylene0.282 in (7.16 mm)ClearPE over pair

Outer Shield

LayerOuter Shield TypeMaterialCoverage
1BraidTinned Copper (TC)95%
2BraidTinned Copper (TC)95%

Outer Jacket

MaterialPVC - Polyvinyl Chloride (Non-Contaminating)
Nom. Diameter0.416 in (10.6 mm)

Electrical Characteristics

Attenuation

FrequencyNom. Attenuation
1 MHz0.30 dB/100ft
10 MHz0.90 dB/100ft
20 MHz1.30 dB/100ft
50 MHz2.10 dB/100ft
100 MHz3.00 dB/100ft
200 MHz4.50 dB/100ft
400 MHz6.30 dB/100ft

Electricals

Nom. Conductor DCR6.6 Ohm/1000ft
Nom. Outer Shield DCR0.9 Ohm/1000ft (3.0 Ohm/km)
Nom. Characteristic Impedance95 Ohm
Nom. Velocity of Prop.66%

Transfer Impedance

FrequencyMax. Transfer Impedance
1 MHz0.7 mOhm/m
10 MHz1.0 mOhm/m
50 MHz7.0 mOhm/m

Voltage

Voltage Rating750 V

Mechanical Characteristics

Max. Pull Tension237 lbs (108 kg)
Bulk Cable Weight113 lbs/1000ft

Temperature

Operating-40°C to +60°C

Bend Radius

Installation Min.4.5 in (110 mm)

Standards and Compliance

Environmental SuitabilityOutdoor, Outdoor
SustainabilityCA Prop 65
Flammability / Reaction to FireVW-1
CPR ComplianceCPR Euroclass: Eca
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.496 Revision Date: 02-20-2026
FootnoteC - CRATE REEL PUT-UP.

Resources