Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 9250 010500.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Computer, Instrumentation
- Outer Jacket Material: PVC - Polyvinyl Chloride (Non-Contaminating)
- Outer Jacket Nom. Diameter: 0.416 in (10.6 mm)
- Electricals Nom. Conductor DCR: 6.6 Ohm/1000ft
- Electricals Nom. Outer Shield DCR: 0.9 Ohm/1000ft (3.0 Ohm/km)
- Electricals Nom. Characteristic Impedance: 95 Ohm
- Electricals Nom. Velocity of Prop.: 66%
- Voltage Voltage Rating: 750 V
Belden 9250 010500 is an orderable item number in the Belden 9250 family (Cable › Coax & Triax Cable › Computer & Instrumentation Cable). Twinax 95Ω RG-22B/U Type, 1 Pair, 18 AWG (7x26) bare copper, polyethylene insulation, polyethylene inner jacket, tinned copper double braid shield (95% coverage each), non-contaminating PVC jacket This item: Color Black, Putup Type Reel, Length 500 ft, UPC 612825225751, Footnote C. Ships from and sold by A5 IT. Quoted to order.
History
| Footnote | C - CRATE REEL PUT-UP. |
| Update And Revision | Revision Number: 0.496 Revision Date: 02-20-2026 |
This Item
| UPC | 612825225751 |
| Color | Black |
| Length | 500 ft |
| Footnote | C |
| Putup Type | Reel |
| Item Number | 9250 010500 |
Product Overview
| Suitable Applications | Computer, Instrumentation |
Construction Details
| RG Type | 22 |
| Conductor Row 1 — Size | 18 AWG |
| Conductor Row 2 — Size | 18 AWG |
| Conductor Row 2 — Notes | Only center strand is Tinned |
| Outer Jacket — Material | PVC - Polyvinyl Chloride (Non-Contaminating) |
| Insulation Row 1 — Notes | PE on both conductors |
| Insulation Row 2 — Notes | PE over pair |
| Conductor Row 1 — Material | BC - Bare Copper |
| Conductor Row 2 — Material | BC+TC - Bare Copper + Tinned Copper |
| Outer Shield Row 1 — Layer | 1 |
| Outer Shield Row 2 — Layer | 2 |
| Conductor Row 1 — Stranding | 7x26 |
| Conductor Row 2 — Stranding | 7x26 |
| Insulation Row 1 — Material | PE - Polyethylene |
| Insulation Row 2 — Material | PE - Polyethylene |
| Outer Jacket — Nom. Diameter | 0.416 in (10.6 mm) |
| Insulation Row 1 — Color Code | Clear |
| Insulation Row 2 — Color Code | Clear |
| Outer Shield Row 1 — Coverage | 95% |
| Outer Shield Row 1 — Material | Tinned Copper (TC) |
| Outer Shield Row 2 — Coverage | 95% |
| Outer Shield Row 2 — Material | Tinned Copper (TC) |
| Overall Cable Diameter (Nominal) | 0.416 in (10.6 mm) |
| Conductor Row 1 — Nom. Diameter | 0.046 in |
| Conductor Row 2 — Nom. Diameter | 0.046 in |
| Outer Shield Row 1 — Outer Shield Type | Braid |
| Outer Shield Row 2 — Outer Shield Type | Braid |
| Insulation Row 1 — Nom. Insulation Diameter | 0.089 in (2.3 mm) |
| Insulation Row 2 — Nom. Insulation Diameter | 0.282 in (7.16 mm) |
Standards And Compliance
| CPR Compliance | CPR Euroclass: Eca |
| Sustainability | CA Prop 65 |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| UK Regulation Compliance | UKCA Mark |
| Environmental Suitability | Outdoor, Outdoor |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | VW-1 |
Electrical Characteristics
| Voltage — Voltage Rating | 750 V |
| Attenuation Row 1 — Frequency | 1 MHz |
| Attenuation Row 2 — Frequency | 10 MHz |
| Attenuation Row 3 — Frequency | 20 MHz |
| Attenuation Row 4 — Frequency | 50 MHz |
| Attenuation Row 5 — Frequency | 100 MHz |
| Attenuation Row 6 — Frequency | 200 MHz |
| Attenuation Row 7 — Frequency | 400 MHz |
| Electricals — Nom. Conductor DCR | 6.6 Ohm/1000ft |
| Electricals — Nom. Outer Shield DCR | 0.9 Ohm/1000ft (3.0 Ohm/km) |
| Attenuation Row 1 — Nom. Attenuation | 0.30 dB/100ft |
| Attenuation Row 2 — Nom. Attenuation | 0.90 dB/100ft |
| Attenuation Row 3 — Nom. Attenuation | 1.30 dB/100ft |
| Attenuation Row 4 — Nom. Attenuation | 2.10 dB/100ft |
| Attenuation Row 5 — Nom. Attenuation | 3.00 dB/100ft |
| Attenuation Row 6 — Nom. Attenuation | 4.50 dB/100ft |
| Attenuation Row 7 — Nom. Attenuation | 6.30 dB/100ft |
| Electricals — Nom. Velocity Of Prop. | 66% |
| Transfer Impedance Row 1 — Frequency | 1 MHz |
| Transfer Impedance Row 2 — Frequency | 10 MHz |
| Transfer Impedance Row 3 — Frequency | 50 MHz |
| Electricals — Nom. Characteristic Impedance | 95 Ohm |
| Transfer Impedance Row 1 — Max. Transfer Impedance | 0.7 mOhm/m |
| Transfer Impedance Row 2 — Max. Transfer Impedance | 1.0 mOhm/m |
| Transfer Impedance Row 3 — Max. Transfer Impedance | 7.0 mOhm/m |
Mechanical Characteristics
| Bulk Cable Weight | 113 lbs/1000ft |
| Max. Pull Tension | 237 lbs (108 kg) |
| Temperature — Operating | -40°C to +60°C |
| Bend Radius — Installation Min. | 4.5 in (110 mm) |