FiberExpress Multi-Fiber Assemblies G.657 A1/A2, LC(UPC)_SX LC(UPC)_SX 144F LSZH Jacket A/B Cross Polarity 0.5m X In-Line 30 m
FiberExpress Multi-Fiber Assemblies, G.657 A1/A2, LC(UPC) Simplex-LC(UPC) Simplex, 144 Fibers, Yellow LSZH Jacket Without Pulling Eye, A/B Cross Polarity, 2.0 mm Fan-out construction, 0.5m x In-line, 30 m Trunk Cable
- Availability
- Asia Pacific
- Status
- Active
Specifications
Product Overview
| Suitable Applications | Data Centers, Main Equipment Rooms |
|---|
Fiber Specifications
| Fiber Type | OS2, G.657.A2 |
|---|---|
| Fiber Core Diameter | 9/125 μm |
| Fiber Count | 144 |
Physical Specifications
Connectors
| Description | Type |
|---|---|
| Connector A (Inside End) | LC Simplex |
| Connector B (Outside End) | LC Simplex |
Fan-out (Legs)
| Description | Length (m) | Geometry |
|---|---|---|
| Connector A (Inside End) | 0.5 m | In-Line |
| Connector B (Outside End) | 0.5 m | In-Line |
Assembly Cable
| Cable Nominal OD | 17.5 mm |
|---|---|
| Jacket Color | Yellow |
Measurement
| Overall Assembly Length | 30 m |
|---|---|
| Packaging | Individually packaged on a reel. |
Optical Characteristics
Fiber Connector Performance
| Connector Type | Max. Insertion Loss | Min. Return Loss |
|---|---|---|
| LC Simplex | 0.25 dB | 55 dB |
| LC Simplex | 0.25 dB | 55 dB |
Mechanical Characteristics
| Minimum Bend Radius During Installation | 350 mm |
|---|---|
| Minimum Bend Radius During Operation | 175 mm |
| Crush Resistance | 1000 N/100mm |
Temperature Range
| Operating Temperature Range | -10°C to +60°C |
|---|---|
| Storage Temperature Range | -10°C to +60°C |
Standards and Compliance
| Environmental Suitability | Indoor |
|---|---|
| Flammability / Reaction to Fire | IEC 60332-1-2 |
| TIA/EIA Compliance | TIA/EIA 568.3 |
| ISO/IEC Compliance | IEC 61754-20 IEC 60793-2-50 IEC 11801 |
| European Directive Compliance | EU Directive 2011/65/EU (RoHS 2) |
Product Notes
| Related Parts | FiberExpress Adapter Strips, FiberExpress Manager Modules and FiberExpress Ultra Frames and Cassettes |
|---|---|
| Notes | Crush resistance values are for Installation |
History
| Update and Revision | Revision Number: 0.4 Revision Date: 10-21-2025 |
|---|
Resources
Related multi-fiber trunks
BeldenA312LCBLCBP010M
A312LCBLCBP010M
OM3 12F LC_SX LC_SX 10M OFNP 900x1.0xIL 900x1.0xIL
BeldenA312LCBLCBPxxxM
A312LCBLCBPxxxM
OM3 12F LC_SX LC_SX xxxM OFNP 900x1.0xIL 900x1.0xIL

A312LD7LD7P010M
OM3 12F LC_DX LC_DX 10M OFNP JKT1.6x1.0 JKT1.6x1.0

A312LD7LD7PxxxM
OM3 12F LC_DX LC_DX xxxM OFNP JKT1.6x1.0 JKT1.6x1.0