
D-Subminiature Assembly, 5 ft, (25) 24 AWG (7x32) TC, S-R PVC/PVC, Foil Shld, CM
Twenty-five 24 AWG stranded (7x32) tinned copper conductors, S-R PVC insulation, Beldfoil® shield, PVC jacket, five foot length.
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
49673A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Length | UPC | Order |
|---|---|---|---|---|
| 49673A 060S2 | Chrome | 5 ft | 612825154198 | Order online |
Specifications
Physical Characteristics (Overall)
| Conductor Count | 25 |
|---|
Conductor
| AWG | 24 |
|---|---|
| Stranding | 7x32 |
| Material | TC - Tinned Copper |
| Nominal Diameter | 0.024 in |
| No. of Conductors | 25 |
Insulation
| Material | SR-PVC - Polyvinyl Chloride (Semi-Rigid) |
|---|---|
| Nominal Wall Thickness | 0.01 in |
Outer Shield
| Type | Tape |
|---|---|
| Material | Bi-Laminate (Alum+Poly) |
| Material Trade Name | Beldfoil® |
| Coverage [%] | 100% |
| Drainwire Material | TC - Tinned Copper |
| Drainwire AWG | 24 |
| Drainwire Construction n x D | 7x32 |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nominal Diameter | 0.339 in |
| Nominal Wall Thickness | 0.032 in |
Electrical Characteristics
Voltage
| UL Voltage Rating | 300 V RMS (UL AWM Style 2464) |
|---|
Temperature Range
| UL Temperature Rating | 80°C (UL AWM Style 2464) |
|---|
Standards
| NEC/(UL) Compliance | CM |
|---|---|
| UL AWM Style Compliance | AWM 2464 (300 V 80°C) (cable only) |
Applicable Environmental and Other Programs
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|---|
| MII Order #39 (China RoHS) | Yes |
Flammability, LS0H, Toxicity Testing
| UL voltage rating | 300 V RMS (UL AWM Style 2464) |
|---|
Plenum/Non-Plenum
| Plenum (Y/N) | No |
|---|
Product Notes
| Notes | Molded handles are 100% shielded to guard against EMI/RFI. All connectors tin-plated and male connectors have detents for a positive shield to ground connection. Wiring is point-to-point with the shield to connector shell. |
|---|
History
| Update and Revision | Revision Number: 0.497 Revision Date: 02-03-2025 |
|---|
Resources
Related copper trunk assemblies

10GX F/UTP CMP PRE-TERM 6
10GX F/UTP CMP Pre-Term 6
69 items
Belden10GX F/UTP CMP PRE-TERM 6 BLUN
10GX F/UTP CMP PRE-TERM 6 BLUN
10GX F/UTP CMP Pre-Terminated 6 Blunt
28 items

10GX F/UTP CMR PRE-TERM 6
10GX F/UTP CMR Pre-Term 6
88 items
Belden10GX F/UTP CMR PRE-TERM 6 BLUN
10GX F/UTP CMR PRE-TERM 6 BLUN
10GX F/UTP CMR Pre-Terminated 6 Blunt
28 items