Belden Store
CX3C0

Product Number: CX3C0

CX3C0 - Broadband Coax 3, 8 AWG Solid BC, Foil + 60% BC Braid, PE Jkt

Broadband Coax 3, 8 AWG Solid Bare Copper Conductor, PE Insulation, Copper Foil + 60% Bare Copper Braid Shield, PE Jacket.

Availability
EMEA | Asia Pacific
Status
Discontinued
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

CX3C0 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthEANOrder
CX3C0+00700BlackReel700 m8719605047519Order online
CX3C0+001050BlackReel1,050 m8719605047502Order online
CX3C0.001050BlackReel1,050 m8719605047410Order online

Specifications

Product Overview

Suitable ApplicationsBroadband, Cable Television (CATV)

Product Life Cycle

Life CycleDiscontinued - the product is no longer manufactured

Construction Details

Series TypeCATV-Trunk Type
Insulation Table NotesCentricity min. 85%
Outer Jacket1 Table NotesAccording to European Standard EN 50290-2-20

Conductor

No. of Elements1
Size8 AWG
StrandingSolid
Nom. Diameter3.38 mm
MaterialBC - Bare Copper

Insulation

ElementInsulated Conductor
MaterialPE - Polyethylene (Foam)
Nom. Insulation Diameter14.9 mm (0.587 in)

Outer Shield

LayerOuter Shield TypeMaterialCoverage
1TapeBare Copper (BC)100%
2BraidBare Copper (BC)55%

Outer Jacket

MaterialPE - Polyethylene
Nom. Diameter19.8 mm (0.780 in)

Electrical Characteristics

Regularity of ImpedanceMin. 46 dB
Return Loss Table NotesIn each frequency band, 3 peak values up to 4 dB lower are allowed
Attenuation Table NotesMax. attenuation 10% higher
Transfer Impedance ClassA+
Screening ClassA+

Return Loss

FrequencyMin. Return Loss
5 - 30 MHz26 dB
30 - 470 MHz26 dB
470 - 862 MHz23 dB
862 - 2400 MHz18 dB

Attenuation

FrequencyNom. Attenuation
5 MHz0.4 dB/100m
50 MHz1.3 dB/100m
100 MHz1.8 dB/100m
200 MHz2.6 dB/100m
400 MHz3.9 dB/100m
600 MHz4.8 dB/100m
800 MHz5.7 dB/100m
862 MHz5.9 dB/100m
1000 MHz6.5 dB/100m
1350 MHz7.7 dB/100m
1750 MHz9 dB/100m
2150 MHz10.2 dB/100m
2400 MHz10.9 dB/100m

Electricals

Max. Conductor DCR1.9 Ohm/km (0.58 Ohm/1000ft)
Nom. Outer Shield DCR2.6 Ohm/km (0.79 Ohm/1000ft)
Nom. Capacitance Cond-to-Shield54 pF/m (16 pF/ft)
Nom. Characteristic Impedance75 Ohm
Nom. Velocity of Prop.84%

Transfer Impedance

FrequencyMax. Transfer Impedance
5 - 30 MHzMax. 2.5 mOhm/m
Typ. 1.1 mOhm/m

Screening

Frequency30 - 1000 MHz
Min. Screening Attenuation95 dB

Mechanical Characteristics

Max. Pull Tension1200 N (270 lbf)
Bulk Cable Weight312 kg/km (210 lbs/1000ft)

Temperature

Operating-40°C To +70°C
Installation-5°C To +50°C
Storage-40°C To +70°C

Bend Radius

Stationary Min.200 mm (7.9 in)

Standards and Compliance

Environmental SuitabilityOutdoor
ISO/IEC ComplianceIEC 61196
CENELEC ComplianceEN 50117-1
European Directive ComplianceEU CE Mark

History

Update and RevisionRevision Number: 0.310 Revision Date: 06-10-2026

Resources

Related catv cable