Key Features
- Suitable Applications: Broadband, Cable Television (CATV)
- Conductor No. of Elements: 1
- Conductor Size: 8 AWG
- Conductor Stranding: Solid
- Conductor Nom. Diameter: 3.38 mm
- Conductor Material: BC - Bare Copper
- Insulation Element: Insulated Conductor
- Insulation Material: PE - Polyethylene (Foam)
Belden CX3C0+001050 is an orderable item number in the Belden CX3C0 family (Cable › Video Cable › CATV Cable). Broadband Coax 3, 8 AWG Solid Bare Copper Conductor, PE Insulation, Copper Foil + 60% Bare Copper Braid Shield, PE Jacket. This item: Color Black, Putup Type Reel, Length 1,050 m, EAN 8719605047502. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.310 Revision Date: 06-10-2026 |
This Item
| EAN | 8719605047502 |
| Color | Black |
| Length | 1,050 m |
| Putup Type | Reel |
| Item Number | CX3C0+001050 |
Product Overview
| Suitable Applications | Broadband, Cable Television (CATV) |
Product Life Cycle
| Life Cycle | Discontinued - the product is no longer manufactured |
Construction Details
| Series Type | CATV-Trunk Type |
| Conductor — Size | 8 AWG |
| Conductor — Material | BC - Bare Copper |
| Insulation Table Notes | Centricity min. 85% |
| Insulation — Element | Insulated Conductor |
| Conductor — Stranding | Solid |
| Insulation — Material | PE - Polyethylene (Foam) |
| Outer Jacket — Material | PE - Polyethylene |
| Outer Jacket1 Table Notes | According to European Standard EN 50290-2-20 |
| Conductor — Nom. Diameter | 3.38 mm |
| Outer Shield Row 1 — Layer | 1 |
| Outer Shield Row 2 — Layer | 2 |
| Conductor — No. Of Elements | 1 |
| Outer Jacket — Nom. Diameter | 19.8 mm (0.780 in) |
| Outer Shield Row 1 — Coverage | 100% |
| Outer Shield Row 1 — Material | Bare Copper (BC) |
| Outer Shield Row 2 — Coverage | 55% |
| Outer Shield Row 2 — Material | Bare Copper (BC) |
| Insulation — Nom. Insulation Diameter | 14.9 mm (0.587 in) |
| Outer Shield Row 1 — Outer Shield Type | Tape |
| Outer Shield Row 2 — Outer Shield Type | Braid |
Standards And Compliance
| CENELEC Compliance | EN 50117-1 |
| ISO/IEC Compliance | IEC 61196 |
| Environmental Suitability | Outdoor |
| European Directive Compliance | EU CE Mark |
Electrical Characteristics
| Screening Class | A+ |
| Attenuation Table Notes | Max. attenuation 10% higher |
| Regularity Of Impedance | Min. 46 dB |
| Return Loss Table Notes | In each frequency band, 3 peak values up to 4 dB lower are allowed |
| Screening — Frequency | 30 - 1000 MHz |
| Transfer Impedance Class | A+ |
| Attenuation Row 1 — Frequency | 5 MHz |
| Attenuation Row 2 — Frequency | 50 MHz |
| Attenuation Row 3 — Frequency | 100 MHz |
| Attenuation Row 4 — Frequency | 200 MHz |
| Attenuation Row 5 — Frequency | 400 MHz |
| Attenuation Row 6 — Frequency | 600 MHz |
| Attenuation Row 7 — Frequency | 800 MHz |
| Attenuation Row 8 — Frequency | 862 MHz |
| Attenuation Row 9 — Frequency | 1000 MHz |
| Return Loss Row 1 — Frequency | 5 - 30 MHz |
| Return Loss Row 2 — Frequency | 30 - 470 MHz |
| Return Loss Row 3 — Frequency | 470 - 862 MHz |
| Return Loss Row 4 — Frequency | 862 - 2400 MHz |
| Attenuation Row 10 — Frequency | 1350 MHz |
| Attenuation Row 11 — Frequency | 1750 MHz |
| Attenuation Row 12 — Frequency | 2150 MHz |
| Attenuation Row 13 — Frequency | 2400 MHz |
| Electricals — Max. Conductor DCR | 1.9 Ohm/km (0.58 Ohm/1000ft) |
| Electricals — Nom. Outer Shield DCR | 2.6 Ohm/km (0.79 Ohm/1000ft) |
| Attenuation Row 1 — Nom. Attenuation | 0.4 dB/100m |
| Attenuation Row 2 — Nom. Attenuation | 1.3 dB/100m |
| Attenuation Row 3 — Nom. Attenuation | 1.8 dB/100m |
| Attenuation Row 4 — Nom. Attenuation | 2.6 dB/100m |
| Attenuation Row 5 — Nom. Attenuation | 3.9 dB/100m |
| Attenuation Row 6 — Nom. Attenuation | 4.8 dB/100m |
| Attenuation Row 7 — Nom. Attenuation | 5.7 dB/100m |
| Attenuation Row 8 — Nom. Attenuation | 5.9 dB/100m |
| Attenuation Row 9 — Nom. Attenuation | 6.5 dB/100m |
| Electricals — Nom. Velocity Of Prop. | 84% |
| Return Loss Row 1 — Min. Return Loss | 26 dB |
| Return Loss Row 2 — Min. Return Loss | 26 dB |
| Return Loss Row 3 — Min. Return Loss | 23 dB |
| Return Loss Row 4 — Min. Return Loss | 18 dB |
| Transfer Impedance Row 1 — Frequency | 5 - 30 MHz |
| Attenuation Row 10 — Nom. Attenuation | 7.7 dB/100m |
| Attenuation Row 11 — Nom. Attenuation | 9 dB/100m |
| Attenuation Row 12 — Nom. Attenuation | 10.2 dB/100m |
| Attenuation Row 13 — Nom. Attenuation | 10.9 dB/100m |
| Screening — Min. Screening Attenuation | 95 dB |
| Electricals — Nom. Characteristic Impedance | 75 Ohm |
| Electricals — Nom. Capacitance Cond-to-Shield | 54 pF/m (16 pF/ft) |
| Transfer Impedance Row 1 — Max. Transfer Impedance | Max. 2.5 mOhm/m |
| Transfer Impedance Row 2 — Max. Transfer Impedance | Typ. 1.1 mOhm/m |
Mechanical Characteristics
| Bulk Cable Weight | 312 kg/km (210 lbs/1000ft) |
| Max. Pull Tension | 1200 N (270 lbf) |
| Temperature — Storage | -40°C To +70°C |
| Temperature — Operating | -40°C To +70°C |
| Temperature — Installation | -5°C To +50°C |
| Bend Radius — Stationary Min. | 200 mm (7.9 in) |