Belden Store
9077

Product Number: 9077

CATV Video, Dual RG6, 18 AWG BCCS, Foil + Braid, CM PVC Jacket

CATV, Series 6, 18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® II, aluminum braid shield (60% coverage), CM PVC jacket.

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

9077 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPut-Up TypeLengthUPCOrder
9077 0101000BlackReel1,000 ft845671002768Order online

Specifications

Physical Characteristics (Overall)

Conductor Count2
Insulation Table NotesGas Injected

Conductor

AWG18
StrandingSolid
MaterialBCCS - Bare Copper Covered Steel
Nominal Diameter0.04 in
No. of Coax2

Insulation

MaterialPE - Polyethylene (Foam)
Nominal Diameter0.18 in

Outer Shield

TypeLayerMaterialMaterial Trade NameCoverage [%]
Tape1Tri-Laminate (Alum+Poly+Alum)Duofoil®100%
Braid2Aluminum60%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nominal Diameter0.27 x 0.59 in

Electrical Characteristics

Conductor DCR

Nominal Conductor DCR28 Ohm/1000ft
Nominal Outer Shield DCR9 Ohm/1000ft
Outer Conductor DCR9 Ohm/1000ft

Capacitance

Nom. Capacitance Conductor to Shield16.2 pF/ft

Inductance

Nominal Inductance0.097 μH/ft

Impedance

Nominal Characteristic Impedance75 Ohm

Return Loss

Frequency [MHz]Min. Structural Return Loss (SRL)
5-1000 MHz20 dB
1000-2250 MHz15 dB
2250-3000 MHz10 dB

Delay

Nominal Delay1.2 ns/ft
Nominal Velocity of Propagation (VP) [%]83%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)
5 MHz0.58 dB/100ft
55 MHz1.6 dB/100ft
211 MHz3.05 dB/100ft
270 MHz3.37 dB/100ft
300 MHz3.55 dB/100ft
350 MHz3.85 dB/100ft
400 MHz4.15 dB/100ft
450 MHz4.4 dB/100ft
550 MHz4.9 dB/100ft
750 MHz5.65 dB/100ft
870 MHz6.11 dB/100ft
1000 MHz6.55 dB/100ft
1500 MHz8.1 dB/100ft
1800 MHz8.8 dB/100ft
2250 MHz10 dB/100ft
3000 MHz11.9 dB/100ft

Voltage

UL Voltage Rating350 V RMS

Temperature Range

Operating Temperature Range-40°C To +80°C

Mechanical Characteristics

Bulk Cable Weight54 lbs/1000ft
Maximum Recommended Pulling Tension252 lbs
Minimum Minor Axis Bend Radius3 in

Standards

NEC/(UL) ComplianceCATV, CM
CEC/C(UL) ComplianceCM
CPR EuroclassEca
RG Type6
Series Type6

Applicable Environmental and Other Programs

Environmental SpaceIndoor (Not Riser or Plenum)
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/96/EC (BFR)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
EU CE MarkNo
MII Order #39 (China RoHS)Yes

Suitability

Suitability - IndoorYes

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1685 UL Loading
UL voltage rating350 V RMS

Plenum/Non-Plenum

Plenum (Y/N)No

History

Update and RevisionRevision Number: 0.426 Revision Date: 02-20-2026

Resources

Related catv cable