Belden Store
Belden 9077 0101000 — CATV Video, Dual RG6, 18 AWG BCCS, Foil + Braid, CM PVC Jacket

Belden Cable

Belden|

MPN: 9077 0101000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 9077 0101000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Conductor AWG: 18
  • Conductor Stranding: Solid
  • Conductor Material: BCCS - Bare Copper Covered Steel
  • Conductor Nominal Diameter: 0.04 in
  • Conductor No. of Coax: 2
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.18 in
  • Outer Jacket Material: PVC - Polyvinyl Chloride
Belden 9077 0101000 is an orderable item number in the Belden 9077 family (Cable › Video Cable › CATV Cable). CATV, Series 6, 18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® II, aluminum braid shield (60% coverage), CM PVC jacket. This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 845671002768. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.426 Revision Date: 02-20-2026

Standards

RG Type6
Series Type6
CPR EuroclassEca
NEC/(UL) ComplianceCATV, CM
CEC/C(UL) ComplianceCM

This Item

UPC845671002768
ColorBlack
Length1,000 ft
Item Number9077 0101000
Put-Up TypeReel

Suitability

Suitability - IndoorYes

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

Operating Temperature Range-40°C To +80°C

Electrical Characteristics

Delay — Nominal Delay1.2 ns/ft
Voltage — UL Voltage Rating350 V RMS
Inductance — Nominal Inductance0.097 μH/ft
Conductor DCR — Outer Conductor DCR9 Ohm/1000ft
Return Loss Row 1 — Frequency [MHz]5-1000 MHz
Return Loss Row 2 — Frequency [MHz]1000-2250 MHz
Return Loss Row 3 — Frequency [MHz]2250-3000 MHz
Conductor DCR — Nominal Conductor DCR28 Ohm/1000ft
High Frequency Row 1 — Frequency [MHz]5 MHz
High Frequency Row 2 — Frequency [MHz]55 MHz
High Frequency Row 3 — Frequency [MHz]211 MHz
High Frequency Row 4 — Frequency [MHz]270 MHz
High Frequency Row 5 — Frequency [MHz]300 MHz
High Frequency Row 6 — Frequency [MHz]350 MHz
High Frequency Row 7 — Frequency [MHz]400 MHz
High Frequency Row 8 — Frequency [MHz]450 MHz
High Frequency Row 9 — Frequency [MHz]550 MHz
High Frequency Row 10 — Frequency [MHz]750 MHz
High Frequency Row 11 — Frequency [MHz]870 MHz
High Frequency Row 12 — Frequency [MHz]1000 MHz
High Frequency Row 13 — Frequency [MHz]1500 MHz
High Frequency Row 14 — Frequency [MHz]1800 MHz
High Frequency Row 15 — Frequency [MHz]2250 MHz
High Frequency Row 16 — Frequency [MHz]3000 MHz
Conductor DCR — Nominal Outer Shield DCR9 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]83%
Capacitance — Nom. Capacitance Conductor To Shield16.2 pF/ft
Return Loss Row 1 — Min. Structural Return Loss (SRL)20 dB
Return Loss Row 2 — Min. Structural Return Loss (SRL)15 dB
Return Loss Row 3 — Min. Structural Return Loss (SRL)10 dB
High Frequency Row 1 — Max. Insertion Loss (Attenuation)0.58 dB/100ft
High Frequency Row 2 — Max. Insertion Loss (Attenuation)1.6 dB/100ft
High Frequency Row 3 — Max. Insertion Loss (Attenuation)3.05 dB/100ft
High Frequency Row 4 — Max. Insertion Loss (Attenuation)3.37 dB/100ft
High Frequency Row 5 — Max. Insertion Loss (Attenuation)3.55 dB/100ft
High Frequency Row 6 — Max. Insertion Loss (Attenuation)3.85 dB/100ft
High Frequency Row 7 — Max. Insertion Loss (Attenuation)4.15 dB/100ft
High Frequency Row 8 — Max. Insertion Loss (Attenuation)4.4 dB/100ft
High Frequency Row 9 — Max. Insertion Loss (Attenuation)4.9 dB/100ft
High Frequency Row 10 — Max. Insertion Loss (Attenuation)5.65 dB/100ft
High Frequency Row 11 — Max. Insertion Loss (Attenuation)6.11 dB/100ft
High Frequency Row 12 — Max. Insertion Loss (Attenuation)6.55 dB/100ft
High Frequency Row 13 — Max. Insertion Loss (Attenuation)8.1 dB/100ft
High Frequency Row 14 — Max. Insertion Loss (Attenuation)8.8 dB/100ft
High Frequency Row 15 — Max. Insertion Loss (Attenuation)10 dB/100ft
High Frequency Row 16 — Max. Insertion Loss (Attenuation)11.9 dB/100ft

Mechanical Characteristics

Bulk Cable Weight54 lbs/1000ft
Minimum Minor Axis Bend Radius3 in
Maximum Recommended Pulling Tension252 lbs

Physical Characteristics (Overall)

Conductor Count2
Conductor — AWG18
Conductor — MaterialBCCS - Bare Copper Covered Steel
Insulation Table NotesGas Injected
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Conductor — No. Of Coax2
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Conductor — Nominal Diameter0.04 in
Insulation — Nominal Diameter0.18 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialAluminum
Outer Jacket — Nominal Diameter0.27 x 0.59 in
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]60%
Outer Shield Row 1 — Material Trade NameDuofoil®

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1685 UL Loading
UL Voltage Rating350 V RMS

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceIndoor (Not Riser or Plenum)
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/96/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account