Belden Store
29727C

Product Number: 29727C

VFD, 3C #2 Str BC XLPE Ins + #5 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B

Belden Basics VFD, 3 Conductor 2AWG (7x10) Bare Copper XLPE Insulation M4 Color Code + 5AWG Symmetrical Segmented Ground (3 of 10AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B SUN RES DIR BUR Oil Resistant

Availability
Global
Status
Active
Orderable items
4

Ships from and sold by A5 IT.

Part numbers

29727C is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeUPCOrder
29727C 0101000Reel612825445708Order online
29727C 0102500Reel612825445715Order online
29727C 0105000Reel612825445722Order online
29727C 0107000Reel—Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.104 Revision Date: 04-01-2026

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements

Construction Details

Overall Cable Diameter (Nominal)1.100 in (27.94 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterialNotes
Conductor(s)32 AWG7x10BC - Bare CopperASTM B3 Copper B8 Class B Stranding
Ground Wire310 AWG7x18BC - Bare CopperSegmented Grounds

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPO - Crosslink Polyolefin0.073 in (1.9 mm)0.428 in (10.9 mm)ICEA Chart M4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverage
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.083 in (2.1 mm)
Nom. Diameter1.100 in (27.94 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR1.48 Ohm/1000ft (4.86 Ohm/km)

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)0.14 Ohm/1000ft (0.46 Ohm/km)21 pF/ft (69 pF/m)38 pF/ft (120 pF/m)90 Ohm55%130 Amps per Conductor at 30oC
1.08 Ohm/1000ft (3.54 Ohm/km)

Voltage

UL Voltage Rating2000 V (TC), 1000 V (CSA AWM I/II A/B)

Mechanical Characteristics

Max. Pull Tension2821 lbs (1280 kg)
Bulk Cable Weight1032 lbs/1000ft (1536 kg/km)

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-40°C To +90°C

Bend Radius

Stationary Min.13.2 in (335 mm)
Installation Min.13.2 in (335 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4, FT4
NEC / UL ComplianceArticle 336, TC-ER, RHW-2
AWM ComplianceAWM I/II A/B
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA

History

Update and RevisionRevision Number: 0.104 Revision Date: 04-01-2026