Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 29727C 0107000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Variable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements
- Outer Jacket Material: PVC - Polyvinyl Chloride
- Outer Jacket Nom. Thickness: 0.083 in (2.1 mm)
- Outer Jacket Nom. Diameter: 1.100 in (27.94 mm)
- Outer Jacket Ripcord: Yes
- Voltage UL Voltage Rating: 2000 V (TC), 1000 V (CSA AWM I/II A/B)
- Temperature UL Temperature: 90°C Dry, 90°C Wet
- Temperature Operating: -40°C To +90°C
Belden 29727C 0107000 is an orderable item number in the Belden 29727C family (Cable › VFD Cable). Belden Basics VFD, 3 Conductor 2AWG (7x10) Bare Copper XLPE Insulation M4 Color Code + 5AWG Symmetrical Segmented Ground (3 of 10AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B SUN RES DIR BUR Oil Resistant This item: Color Black, Putup Type Reel, Length 7,000 ft. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.104 Revision Date: 04-01-2026 |
This Item
| Color | Black |
| Length | 7,000 ft |
| Putup Type | Reel |
| Item Number | 29727C 0107000 |
Information
| Put-Up Type | Reel |
| Update And Revision | Revision Number: 0.104 Revision Date: 04-01-2026 |
Product Overview
| Suitable Applications | Variable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements |
Construction Details
| Conductor Row 1 — Size | 2 AWG |
| Conductor Row 2 — Size | 10 AWG |
| Outer Jacket — Ripcord | Yes |
| Conductor Row 1 — Notes | ASTM B3 Copper B8 Class B Stranding |
| Conductor Row 2 — Notes | Segmented Grounds |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Conductor Row 1 — Element | Conductor(s) |
| Conductor Row 2 — Element | Ground Wire |
| Conductor Row 1 — Material | BC - Bare Copper |
| Conductor Row 2 — Material | BC - Bare Copper |
| Insulation Row 1 — Element | Conductor(s) |
| Insulation Row 2 — Element | Ground Wire |
| Conductor Row 1 — Stranding | 7x10 |
| Conductor Row 2 — Stranding | 7x18 |
| Insulation Row 1 — Material | XLPO - Crosslink Polyolefin |
| Insulation Row 2 — Material | No Insulation |
| Outer Jacket — Nom. Diameter | 1.100 in (27.94 mm) |
| Insulation Row 1 — Color Code | ICEA Chart M4 |
| Outer Jacket — Nom. Thickness | 0.083 in (2.1 mm) |
| Outer Shield Row 1 — Coverage | 100% |
| Outer Shield Row 1 — Material | Bare Copper (BC) |
| Outer Shield Row 2 — Coverage | 100% |
| Outer Shield Row 2 — Material | Bare Copper (BC) |
| Overall Cable Diameter (Nominal) | 1.100 in (27.94 mm) |
| Outer Shield Row 1 — Shield Type | Helical Tape |
| Outer Shield Row 2 — Shield Type | Helical Tape |
| Conductor Row 1 — No. Of Elements | 3 |
| Conductor Row 2 — No. Of Elements | 3 |
| Insulation Row 1 — Nom. Thickness | 0.073 in (1.9 mm) |
| Insulation Row 1 — Nom. Insulation Diameter | 0.428 in (10.9 mm) |
Standards And Compliance
| AWM Compliance | AWM I/II A/B |
| Sustainability | CA Prop 65 |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| ICEA Compliance | S-95-658 |
| NEC / UL Compliance | Article 336, TC-ER, RHW-2 |
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| Other Standard Compliance(s) | P-07-KA070003-MSHA |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | UL 1685 UL Loading, IEEE 1202 FT4, FT4 |
Electrical Characteristics
| Nom Outer Shield DCR | 1.48 Ohm/1000ft (4.86 Ohm/km) |
| Electricals Row 1 — Element | Conductor(s) |
| Voltage — UL Voltage Rating | 2000 V (TC), 1000 V (CSA AWM I/II A/B) |
| Electricals Row 1 — Max. Current | 130 Amps per Conductor at 30oC |
| Electricals Row 1 — Nom. Conductor DCR | 0.14 Ohm/1000ft (0.46 Ohm/km) |
| Electricals Row 2 — Nom. Conductor DCR | 1.08 Ohm/1000ft (3.54 Ohm/km) |
| Electricals Row 1 — Nom. Velocity Of Prop. | 55% |
| Electricals Row 1 — Nom. Capacitance Cond-to-Cond | 21 pF/ft (69 pF/m) |
| Electricals Row 1 — Nom. Characteristic Impedence | 90 Ohm |
| Electricals Row 1 — Nom. Capacitance Cond-to-Other (Conds + Shield) | 38 pF/ft (120 pF/m) |
Mechanical Characteristics
| Bulk Cable Weight | 1032 lbs/1000ft (1536 kg/km) |
| Max. Pull Tension | 2821 lbs (1280 kg) |
| Temperature — Operating | -40°C To +90°C |
| Temperature — UL Temperature | 90°C Dry, 90°C Wet |
| Bend Radius — Stationary Min. | 13.2 in (335 mm) |
| Bend Radius — Installation Min. | 13.2 in (335 mm) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing