Belden Store
29537

Product Number: 29537

VFD 300% Gnd, 3C+G #12 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd w/#12 TC Drain, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 2000V Flexible Motor Supply Cable WTTC

Belden 300% Ground Flexible VFD, 3 Conductor 12AWG (65x30) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil®+Tinned Copper Braid(85%) Shield w/12AWG Tinned Copper Drain, Black PVC Outer Jacket, 2000V TC-ER 90C Dry/Wet 2000V Flexible Motor Supply Cable WTTC 1000V CSA AWM I/II A/B 600V CIC TC SUN RES DIR BUR Oil Resistant

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

29537 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCOrder
29537 0101000BlackReel1,000 ft612825138419Order online
29537 0105000BlackReel5,000 ft612825138426Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.541 Revision Date: 02-20-2026

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements

Construction Details

Overall Cable Diameter (Nominal)0.723 in (18.4 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)312 AWG65x30TC - Tinned Copper
Ground Wire112 AWG65x30TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.066 in (1.7 mm)0.225 in (5.72 mm)ICEA Chart M4
Ground WireXLPE - Cross-Linked Polyethylene (Thermoset)0.066 in (1.7 mm)0.225 in (5.72 mm)Green/Yellow Stripe

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeTri-Laminate (Alum+Poly+Alum)100%12 AWG (65x30) TC
BraidTinned Copper (TC)85%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.073 in (1.9 mm)
Nom. Diameter0.723 in (18.4 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR0.68 Ohm/1000ft (2.2 Ohm/km)

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. InductanceNom. Velocity of Prop.Max. Current
Conductor(s)1.569 Ohm/1000ft54 pF/ft (180 pF/m)97 pF/ft (320 pF/m)44 Ohm0.197 μH/ft (0.646 μH/m)55%30 Amps per Conductor at 30oC
1.72 Ohm/1000ft (5.64 Ohm/km)30 Amps per Conductor at 30oC

Voltage

UL Voltage Rating2000 V (TC, C(UL) TC), 1000 V (WTTC, UL Flexible Motor Supply Cable, CSA AWM I/II A/B)

Mechanical Characteristics

Max. Pull Tension7922 lbs (3593 kg)
Bulk Cable Weight336 lbs/1000ft

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-40°C To +90°C

Bend Radius

Stationary Min.8.7 in (220 mm)
Installation Min.8.7 in (220 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, FT4, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, TC-ER, WTTC, UL Flexible Motor Supply Cable
AWM ComplianceAWM I/II A/B
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA

History

Update and RevisionRevision Number: 0.541 Revision Date: 02-20-2026

Resources

Related vfd cable