Belden Store
29530C

Product Number: 29530C

VFD, 3C #2/0 Str BC XLPE Ins + #5 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V

Belden Basics VFD, 3 Conductor 2/0AWG (19x12) Bare Copper XLPE Insulation M4 Color Code + 5AWG Symmetrical Segmented Ground (3 of 10AWG) Bare Copper Stranded in Continuous Contact with Overall Dual Copper Tape Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V SUN RES DIR BUR Oil Resistant

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

29530C is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCOrder
29530C 0102000BlackReel2,000 ft612825138105Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.677 Revision Date: 03-30-2026

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations

Construction Details

Overall Cable Diameter (Nominal)1.305 in (33.15 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterialNotes
Conductor(s)32/0 AWG19x12BC - Bare CopperASTM B3 Copper B8 Class B Stranding
Ground Wire310 AWG7x18BC - Bare CopperSegmented Ground (3 Total 5AWG)

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPO - Crosslink Polyolefin0.057 in (1.4 mm)0.516 in (13.1 mm)ICEA Chart M4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverage
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.083 in (2.1 mm)
Nom. Diameter1.305 in (33.15 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR1.36 Ohm/1000ft (4.46 Ohm/km)

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. InductanceNom. Velocity of Prop.Max. Current
Conductor(s)0.082 Ohm/1000ft (0.27 Ohm/km)32 pF/ft (100 pF/m)57 pF/ft (190 pF/m)50 Ohm0.141 μH/ft (0.463 μH/m)55%195 Amps per Conductor at 30oC (per NEC)
0.030 Ohm/1000ft (0.098 Ohm/km)

Voltage

UL Voltage Rating1000 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension5301 lbs (2404 kg)
Bulk Cable Weight1724 lbs/1000ft (2566 kg/km)

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-40°C To +90°C

Bend Radius

Stationary Min.15.7 in (399 mm)
Installation Min.15.7 in (399 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4, FT4
NEC / UL ComplianceArticle 336, TC-ER, XHHW-2
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA

History

Update and RevisionRevision Number: 0.677 Revision Date: 03-30-2026

Resources