Belden Store
29527C

Product Number: 29527C

VFD, 3C #2 Str BC XLPE Ins + #5 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V

Belden Basics VFD, 3 Conductor 2AWG (7x10) Bare Copper XLPE Insulation M4 Color Code + 5AWG Symmetrical Segmented Ground (3 of 10AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V SUN RES DIR BUR Oil Resistant

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

29527C is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCOrder
29527C 0102000BlackReel2,000 ft612825137825Order online
29527C 0105000BlackReel5,000 ft612825137832Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.727 Revision Date: 04-01-2026

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems, Class 1 Division 2 Hazardous Locations

Construction Details

Overall Cable Diameter (Nominal)0.990 in (25.1 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterialNotes
Conductor(s)32 AWG7x10BC - Bare CopperASTM B3 Copper B8 Class B Stranding
Segmented Ground Wire310 AWG7x18BC - Bare CopperSegmented Ground (3 Totaling 5AWG)

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.047 in (1.2 mm)0.377 in (9.58 mm)ICEA Chart M4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverage
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.083 in (2.1 mm)
Nom. Diameter0.990 in (25.1 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR2.04 Ohm/1000ft (6.69 Ohm/km)

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)0.14 Ohm/1000ft (0.46 Ohm/km)35 pF/ft (110 pF/m)68 pF/ft (220 pF/m)44 Ohm55%130 Amps per Conductor at 30oC
0.03 Ohm/1000ft (0.098 Ohm/km)

Voltage

UL Voltage Rating1000 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension2851 lbs (1293 kg)
Bulk Cable Weight969 lbs/1000ft (1440 kg/km)

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-40°C To +90°C

Bend Radius

Stationary Min.11.9 in (302 mm)
Installation Min.11.9 in (302 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4, FT4
NEC / UL ComplianceArticle 336, TC-ER, XHHW-2
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA

History

Update and RevisionRevision Number: 0.727 Revision Date: 04-01-2026

Resources

Related vfd cable