Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 29527C 0105000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Variable Frequency Drives (VFD); AC Motor and Drive Systems, Class 1 Division 2 Hazardous Locations
- Outer Jacket Material: PVC - Polyvinyl Chloride
- Outer Jacket Nom. Thickness: 0.083 in (2.1 mm)
- Outer Jacket Nom. Diameter: 0.990 in (25.1 mm)
- Outer Jacket Ripcord: Yes
- Voltage UL Voltage Rating: 1000 V (TC-ER)
- Temperature UL Temperature: 90°C Dry, 90°C Wet
- Temperature Operating: -40°C To +90°C
Belden 29527C 0105000 is an orderable item number in the Belden 29527C family (Cable › VFD Cable). Belden Basics VFD, 3 Conductor 2AWG (7x10) Bare Copper XLPE Insulation M4 Color Code + 5AWG Symmetrical Segmented Ground (3 of 10AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V SUN RES DIR BUR Oil Resistant This item: Color Black, Putup Type Reel, Length 5,000 ft, UPC 612825137832. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.727 Revision Date: 04-01-2026 |
This Item
| UPC | 612825137832 |
| Color | Black |
| Length | 5,000 ft |
| Putup Type | Reel |
| Item Number | 29527C 0105000 |
Information
| Put-Up Type | Reel |
| Update And Revision | Revision Number: 0.727 Revision Date: 04-01-2026 |
Product Overview
| Suitable Applications | Variable Frequency Drives (VFD); AC Motor and Drive Systems, Class 1 Division 2 Hazardous Locations |
Construction Details
| Conductor Row 1 — Size | 2 AWG |
| Conductor Row 2 — Size | 10 AWG |
| Outer Jacket — Ripcord | Yes |
| Conductor Row 1 — Notes | ASTM B3 Copper B8 Class B Stranding |
| Conductor Row 2 — Notes | Segmented Ground (3 Totaling 5AWG) |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Conductor Row 1 — Element | Conductor(s) |
| Conductor Row 2 — Element | Segmented Ground Wire |
| Conductor Row 1 — Material | BC - Bare Copper |
| Conductor Row 2 — Material | BC - Bare Copper |
| Insulation Row 1 — Element | Conductor(s) |
| Insulation Row 2 — Element | Ground Wire |
| Conductor Row 1 — Stranding | 7x10 |
| Conductor Row 2 — Stranding | 7x18 |
| Insulation Row 1 — Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Insulation Row 2 — Material | No Insulation |
| Outer Jacket — Nom. Diameter | 0.990 in (25.1 mm) |
| Insulation Row 1 — Color Code | ICEA Chart M4 |
| Outer Jacket — Nom. Thickness | 0.083 in (2.1 mm) |
| Outer Shield Row 1 — Coverage | 100% |
| Outer Shield Row 1 — Material | Bare Copper (BC) |
| Outer Shield Row 2 — Coverage | 100% |
| Outer Shield Row 2 — Material | Bare Copper (BC) |
| Overall Cable Diameter (Nominal) | 0.990 in (25.1 mm) |
| Outer Shield Row 1 — Shield Type | Helical Tape |
| Outer Shield Row 2 — Shield Type | Helical Tape |
| Conductor Row 1 — No. Of Elements | 3 |
| Conductor Row 2 — No. Of Elements | 3 |
| Insulation Row 1 — Nom. Thickness | 0.047 in (1.2 mm) |
| Insulation Row 1 — Nom. Insulation Diameter | 0.377 in (9.58 mm) |
Standards And Compliance
| Sustainability | CA Prop 65 |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| ICEA Compliance | S-95-658 |
| NEC / UL Compliance | Article 336, TC-ER, XHHW-2 |
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| Other Standard Compliance(s) | P-07-KA070003-MSHA |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | UL 1685 UL Loading, IEEE 1202 FT4, FT4 |
Electrical Characteristics
| Nom Outer Shield DCR | 2.04 Ohm/1000ft (6.69 Ohm/km) |
| Electricals Row 1 — Element | Conductor(s) |
| Voltage — UL Voltage Rating | 1000 V (TC-ER) |
| Electricals Row 1 — Max. Current | 130 Amps per Conductor at 30oC |
| Electricals Row 1 — Nom. Conductor DCR | 0.14 Ohm/1000ft (0.46 Ohm/km) |
| Electricals Row 2 — Nom. Conductor DCR | 0.03 Ohm/1000ft (0.098 Ohm/km) |
| Electricals Row 1 — Nom. Velocity Of Prop. | 55% |
| Electricals Row 1 — Nom. Capacitance Cond-to-Cond | 35 pF/ft (110 pF/m) |
| Electricals Row 1 — Nom. Characteristic Impedence | 44 Ohm |
| Electricals Row 1 — Nom. Capacitance Cond-to-Other (Conds + Shield) | 68 pF/ft (220 pF/m) |
Mechanical Characteristics
| Bulk Cable Weight | 969 lbs/1000ft (1440 kg/km) |
| Max. Pull Tension | 2851 lbs (1293 kg) |
| Temperature — Operating | -40°C To +90°C |
| Temperature — UL Temperature | 90°C Dry, 90°C Wet |
| Bend Radius — Stationary Min. | 11.9 in (302 mm) |
| Bend Radius — Installation Min. | 11.9 in (302 mm) |