Belden Store
5202F1

Product Number: 5202F1

Security & Sound, #16-4c, TC, Shielded, CMG-FPL-PLTC, Water-Blocked

Security & Sound Cable, Rated-CMG-FPL-PLTC, 4-16 AWG stranded tinned copper conductors with PVC insulation, waterblocking tape, Beldfoil® shield and PVC jacket

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

5202F1 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorUPCFootnoteOrder
5202F1 0101000Black612825157892COrder online
5202F1 0021000Red612825157885COrder online

Specifications

Product Overview

Suitable ApplicationsSecurity System, Intercom/PA, Audio/Speaker, Power-Limited Controls, Noisy & Wet Location, Below-Grade Duct

Construction Details

WaterblockingWaterblock Tape

Conductor

ElementConductor(s)
No. of Elements4
Size16
Stranding7x24
MaterialTC - Tinned Copper

Insulation

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.007 in (0.18 mm)
Nom. Insulation Diameter0.073 in (1.9 mm)
Color CodeBlack, White, Red, Green

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type18 AWG (19x30) TC

Outer Jacket

SeparatorWaterblocking Tape
MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.042 in (1.1 mm)
Nom. Diameter0.295 in (7.49 mm)

Electrical Characteristics

Nom Outer Shield DCR4.5 Ohm/1000ft (15 Ohm/km)

Electricals

Nom. Conductor DCR4.35 Ohm/1000ft (14.3 Ohm/km)
Nom. Capacitance Cond-to-Cond43 pF/ft (140 pF/m)
Max. Current9 Amps per Conductor at 25oC

Voltage

UL Voltage Rating300 V

Mechanical Characteristics

Max. Pull Tension165 lbs (74.8 kg)
Bulk Cable Weight67 lbs/1000ft (100 kg/km)

Temperature

UL Temperature105°C
Operating-20°C To +105°C

Bend Radius

Stationary Min.2.95 in (74.9 mm)
Installation Min.2.95 in (74.9 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
SustainabilityProduct LensTM, Environmental Product Declaration (EPD) Available
Flammability / Reaction to FireUL1685 FT4 loading, FT4, IEEE 1202 FT4
NEC / UL ComplianceArticle 725, Article 760, Article 800, CMG, FPL, PLTC
CEC / C(UL) ComplianceCMG.
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.575 Revision Date: 08-25-2026
FootnoteC - CRATE REEL PUT-UP.