
ACIC 600V, 8 Pr #16 Str TC, XLPE Ins E1, OS, PVC Inner Jkt, SIA Armor, Blk PVC Jkt, 90C Wet 105C Dry CSA HLABCD SUN RES -40C
Canadian Instrumentation Cable TC-ACIC 600V, 8 Pair 16AWG (7x24) Tinned Copper, XLPE Insulation E1 Color Code, Overall Beldfoil® Shield, PVC Inner Jacket, Steel Interlock Armor, Black PVC Outer Jacket, 90C Wet 105C Dry CSA HLABCD SUN RES -40C
- Availability
- Global
- Status
- Active
Specifications
Information
| Put-Up Type | Reel |
|---|---|
| Update and Revision | Revision Number: 0.4 Revision Date: 02-27-2026 |
Product Overview
| Suitable Applications | Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, ...), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners |
|---|
Construction Details
Conductor
| Element | Pair(s) |
|---|---|
| No. of Elements | 8 |
| Size | 16 AWG |
| Stranding | 7x24 |
| Material | TC - Tinned Copper |
Insulation
| Element | Pair(s) |
|---|---|
| Material | XLP, XLPO, XLPE (Thermoset) |
| Color Code | Black, White and Numbered |
Inner Shield
| Shield Type | Tape |
|---|---|
| Material | Bi-Laminate (Alum+Poly) |
Outer Shield
| Shield Type | Tape |
|---|---|
| Material | Bi-Laminate (Alum+Poly) |
| Drainwire Type | 18 AWG (7x26) TC |
Inner Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Diameter | 0.90 in (23 mm) |
| Ripcord | Yes |
Armor
| Armor Type & Material | SIA - Steel Interlock Armor |
|---|---|
| Armor Thickness | 1.28 in (32.5 mm) |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Diameter | 1.18 in (30.0 mm) |
| Ripcord | Yes |
Mechanical Characteristics
| Max. Pull Tension | 786 lbs (357 kg) |
|---|---|
| Bulk Cable Weight | 1071 lbs/1000ft (1594 kg/km) |
Temperature
| Operating | -40°C To +105°C Dry/90°C Wet |
|---|
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, UV Resistance |
|---|---|
| CEC / C(UL) Compliance | ACIC, HLBCD. |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
| Update and Revision | Revision Number: 0.4 Revision Date: 02-27-2026 |
|---|
Resources
Related acic cable

22603D
CIC 300V, 1 Tri #16 Str BC, XLPE Ins E1, OS, Blk PVC Jkt, 90C Dry/Wet SUN RES -25C

22635
CIC 300V, 8 Pr #18 Str TC, PVC Ins E1, IS/OS, Blk PVC Jkt, 105C Dry 75C Wet SUN RES -25C
TC - Tinned Copper · PVC - Polyvinyl Chloride

22645
CIC 300V, 1 Pr #18 Str TC, PVC Ins E1, OS, Blk PVC Jkt, 105C Dry 75C Wet SUN RES -25C
TC - Tinned Copper · PVC - Polyvinyl Chloride · 300 V RMS

22677
CIC 300V, 1 Tri #18 Str TC, PVC Ins E1, OS, Blk PVC Jkt, 105C Dry 75C Wet SUN RES -25C
TC - Tinned Copper · PVC - Polyvinyl Chloride