ACIC 600V, 12 Pr #18 Str TC, XLPE Ins E1, IS/OS, PVC Jkt, AIA Armor, Blk PVC Jkt, 90C Wet 105C Dry CSA HLABCD SUN RES -40C

Canadian Instrumentation Cable TC-ACIC 600V, 12 Pair 18AWG (7x26) Tinned Copper, XLPE Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, PVC Inner Jacket, Aluminum Interlock Armor, Black PVC Outer Jacket, 90C Wet 105C Dry CSA HLABCD SUN RES -40C

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.54 Revision Date: 02-25-2026

Product Overview

Suitable ApplicationsIndustrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, ...), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners

Physical Characteristics (Overall)

Conductor Count24

Conductor

ElementPair(s)
AWG18
Stranding7x26
MaterialTC - Tinned Copper
No. of Pairs12

Insulation

ElementPair(s)
MaterialXLP, XLPO, XLPE (Thermoset)
Nominal Wall Thickness0.03 in

Color Chart

ColorBlack & White and Numbered

Inner Shield

TypeTape
MaterialBi-Laminate (Alum+Poly)
Material Trade NameBeldfoil®
Coverage [%]100%
Drainwire MaterialTC - Tinned Copper
Drainwire AWG20

Inner Jacket

MaterialPVC - Polyvinyl Chloride
ColorBlack
Nominal Diameter0.989 in
RipcordYes

Outer Shield

TypeTape
MaterialBi-Laminate (Alum+Poly)
Material Trade NameBeldfoil®
Coverage [%]100%
Drainwire MaterialTC - Tinned Copper
Drainwire AWG18

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nominal Diameter1.353 in
Nominal Wall Thickness0.031 in
RipcordYes

Construction and Dimensions

Armor

Type of ArmorInterlocked Aluminum
MaterialAluminum

Electrical Characteristics

Conductor DCR

Nominal Conductor DCR14.7 Ohm/1000ft

Voltage

Non-UL Voltage Rating600 V

Temperature Range

Operating Temperature Range-40°C To +105°C Dry/90°C Wet

Mechanical Characteristics

UV ResistanceYes
Bulk Cable Weight741 lbs/1000ft
Maximum Recommended Pulling Tension200 Lbs.
Minimum Bend Radius During Installation16.2 In

Standards

CEC/C(UL) ComplianceACIC
CSA AWM ComplianceC22.2 #239 Type ACIC, C22.2 #174 HL BCD
CSA TypeCSA C22.2 #239,CSA C22.2 #174

Suitability

Suitability - IndoorYes
Suitability - OutdoorYes
Suitability - Sunlight ResistanceYes

History

Update and RevisionRevision Number: 0.54 Revision Date: 02-25-2026